ASTM E 1742 : 2000

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Practice for Radiographic Examination

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Superseded by

ASTM E 1742 : 2005

Language(s)

English

Published date

10-07-2000

$135.86
Including GST where applicable

Committee
E 07
DocumentType
Standard Practice
Pages
14
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1 This practice establishes the minimum requirements for radiographic examination for metallic and nonmetallic materials.

1.2 Applicability -The criteria for the radiographic examination in this practice are applicable to all types of metallic and nonmetallic materials. The requirements expressed in this practice are intended to control the quality of the radiographic images and are not intended to establish acceptance criteria for parts and materials.

1.3 Basis of Application -There are areas in this practice that may require agreement between the cognizant engineering organization and the supplier, or specific direction from the cognizant engineering organization. These items should be addressed in the purchase order or the contract.

1.3.1 DoD contracts, 2.10.

1.3.2 Personnel qualification, 5.1.1.

1.3.3 Agency qualification, 5.1.2.

1.3.4 Digitizing techniques, 5.4.5.

1.3.5 Alternate image quality indicator (IQI) types, 5.5.3.

1.3.6 Examination sequence, 6.6.

1.3.7 Non-film techniques, 6.7.

1.3.8 Radiographic quality levels, 6.9.

1.3.9 Film density, 6.10.

1.3.10 IQI qualification exposure, 6.13.3.

1.3.11 Non-requirement for IQI, 6.18.4.

1.3.12 Examination coverage for welds, A2.2.2.

1.3.13 Electron beam welds, A2.3.

1.3.14 Geometric unsharpness, 6.23.

1.3.15 Responsibility for examination, 6.27.1.

1.3.16 Examination report, 6.27.2.

1.3.17 Retention of radiographs, 6.27.8.

1.3.18 Storage of radiographs, 6.27.9.

1.3.19 Reproduction of radiographs, 6.27.10 and 6.27.10.1.

1.3.20 Acceptable parts, 6.28.1.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM E 1030/E1030M : 2015 Standard Practice for Radiographic Examination of Metallic Castings
ASTM E 1647 : 2016 Standard Practice for Determining Contrast Sensitivity in Radiology
ASTM E 1000 : 2016 Standard Guide for Radioscopy
ASTM E 1161 : 2009 : R2014 Standard Practice for Radiologic Examination of Semiconductors and Electronic Components
ASTM E 1734 : 2016 : REV A Standard Practice for Radioscopic Examination of Castings
ASTM E 94/E94M : 2017 Standard Guide for Radiographic Examination Using Industrial Radiographic Film
ASTM E 2533 : 2017 : EDT 1 Standard Guide for Nondestructive Testing of Polymer Matrix Composites Used in Aerospace Applications
ASTM E 543 : 2015 Standard Specification for Agencies Performing Nondestructive Testing
ASTM F 3184 : 2016 Standard Specification for Additive Manufacturing Stainless Steel Alloy (UNS S31603) with Powder Bed Fusion
ASTM E 1255 : 2016 Standard Practice for Radioscopy
ASTM E 1416 : 2016 : REV A Standard Practice for Radioscopic Examination of Weldments
ASTM E 2662 : 2015 Standard Practice for Radiographic Examination of Flat Panel Composites and Sandwich Core Materials Used in Aerospace Applications
ASTM E 592 : 2015 Standard Guide to Obtainable ASTM Equivalent Penetrameter Sensitivity for Radiography of Steel Plates <fraction><num>1</num><den>4 </den></fraction> to 2 in. (6 to 51 mm) Thick with X-Rays and 1 to 6 in. (25 to 152 mm) Thick with <brk/>Cobalt-60
ASTM F 3302 : 2018 Standard for Additive Manufacturing – Finished Part Properties – Standard Specification for Titanium Alloys via Powder Bed Fusion
ASTM F 2895 : 2015 Standard Practice for Digital Radiography of Cast Metallic Implants
ASTM F 3318 : 2018 Standard for Additive Manufacturing – Finished Part Properties – Specification for AlSi10Mg with Powder Bed Fusion – Laser Beam
ASTM E 2033 : 2017 Standard Practice for Radiographic Examination Using Computed Radiography (Photostimulable Luminescence Method)
ASTM E 1032 : 2019 Standard Practice for Radiographic Examination of Weldments Using Industrial X-Ray Film
ASTM E 1475 : 2013 : R2018 Standard Guide for Data Fields for Computerized Transfer of Digital Radiological Examination Data

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more