ASTM E 1646 : 1995 : R2018
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference
Hardcopy , PDF
18-10-2024
English
01-11-2018
CONTAINED IN VOL. 04.11, 2015 Defines the determination of the resistance of exterior metal roof panel systems to water penetration when water is applied to the outdoor face simultaneously with a static air pressure at the outdoor face higher than the pressure at the indoor face, that is, positive pressure.
Committee |
E 06
|
DocumentType |
Test Method
|
Pages |
6
|
ProductNote |
Reconfirmed 1995
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This test method covers the determination of the resistance of exterior metal roof panel systems to water penetration when water is applied to the outdoor face simultaneously with a static air pressure at the outdoor face higher than the pressure at the indoor face, that is, positive pressure. This test method is a specialized adaption of Test Method E331.
1.2This test method is applicable to any roof area and is intended to measure only the water penetration associated with the field of roof including panel side laps and structural connections. It does not include leakage at openings or perimeter or any other details.
1.3This test method is limited to specimens in which the side seams and attachments are clearly visible and in which the source of leakage is readily determined. Composite systems in which the source cannot be readily determined are outside the scope of this test method.
1.4The proper use of this test method requires a knowledge of the principles of pressure and flow measurement.
1.5The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6The text of this test method references notes and footnotes excluding tables and figures, which provide explanatory material. These notes and footnotes shall not be considered as requirements of the test method.
1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 7.1.
1.8This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM E 1680 : 2016 | Standard Test Method for Rate of Air Leakage through Exterior Metal Roof Panel Systems |
ASTM E 1514 : 1998 : R2017 : EDT 1 | Standard Specification for Structural Standing Seam Steel Roof Panel Systems |
ASTM E 1637 : 1998 : R2017 : EDT 1 | Standard Specification for Structural Standing Seam Aluminum Roof Panel Systems |
ASTM E 2140 : 2001 : R2017 | Standard Test Method for Water Penetration of Metal Roof Panel Systems by Static Water Pressure Head |
ASTM E 1514 : 1998 : R2023 : EDT 1 | Standard Specification for Structural Standing Seam Steel Roof Panel Systems |
ASTM E 2140 : 2001 : R2023 | Standard Test Method for Water Penetration of Metal Roof Panel Systems by Static Water Pressure Head |
ASTM E 631 : 2015 : REDLINE | Standard Terminology of Building Constructions |
ASTM E 1592 : 2005 : R2017 | Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference |
ASTM E 1680 : 2016 : REDLINE | Standard Test Method for Rate of Air Leakage through Exterior Metal Roof Panel Systems |
ASTM E 1592 : 2001 | Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference |
ASTM E 1680 : 2011 | Standard Test Method for Rate of Air Leakage Through Exterior Metal Roof Panel Systems |
ASTM E 631 : 2015 : R2024 | Standard Terminology of Building Constructions |
ASTM E 331 : 2000 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference |
ASTM E 1592 : 1998 | Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference |
ASTM E 1680 : 2016 | Standard Test Method for Rate of Air Leakage through Exterior Metal Roof Panel Systems |
ASTM E 631 : 2015 | Standard Terminology of Building Constructions |
ASTM E 331 : 2000 : R2023 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference |
ASTM E 1680 : 1995 | Standard Test Method for Rate of Air Leakage Through Exterior Metal Roof Panel Systems |
ASTM E 331 : 2000 : R2016 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference |
ASTM E 1592 : 2005 | Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference |
ASTM E 1680 : 2016 : R2022 | Standard Test Method for Rate of Air Leakage through Exterior Metal Roof Panel Systems |
ASTM E 1592 : 2005 : R2012 | Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.