ASTM D 8207 : 2018
Current
The latest, up-to-date edition.
Standard Test Method for Determination of Metals in Purified Terephthalic Acid (PAT) by Atomic Absorption (AA) Spectrometry (Withdrawn 2023)
Hardcopy , PDF
English
17-08-2018
1.1 This test method covers the determination of aluminum, chromium, cobalt, titanium, iron, manganese, molybdenum, sodium and nickel in purified terephthalic acid (PAT) by graphite furnace atomic absorption (GFAA) spectrometry. It is applicable to PAT samples containing sodium, chromium, cobalt, titanium, manganese, molybdenum and nickel over 0.004 mg/kg, and iron and aluminum over 0.054 mg/kg. 1.2 In determining the conformance of the test results using this method to applicable specification, results shall be rounded off in accordance with the rounding-off method of Practice E29. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Some specific hazards statements are given in 6.3, 6.10, 6.11, Section , and 9.1. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Committee |
D 16
|
DocumentType |
Test Method
|
Pages |
4
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
1.1This test method covers the determination of aluminum, chromium, cobalt, titanium, iron, manganese, molybdenum, sodium and nickel in purified terephthalic acid (PAT) by graphite furnace atomic absorption (GFAA) spectrometry. It is applicable to PAT samples containing sodium, chromium, cobalt, titanium, manganese, molybdenum and nickel over 0.004 mg/kg, and iron and aluminum over 0.054 mg/kg.
1.2In determining the conformance of the test results using this method to applicable specification, results shall be rounded off in accordance with the rounding-off method of Practice E29.
1.3The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Some specific hazards statements are given in 6.3, 6.10, 6.11, Section , and 9.1.
1.5This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM D 8062 : 2023 | Standard Specification for Purified Terephthalic Acid (PTA) with Low <emph type="ital" >p</emph>-Toluic Acid |
ASTM D 6809 : 2002 : R2016 | Standard Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related Materials |
ASTM D 6809 : 2020 | Standard Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related Materials |
ASTM E 177 : 1990 : REV A : R1996 | Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods |
ASTM E 1184 : 2010 : R2016 | Standard Practice for Determination of Elements by Graphite Furnace Atomic Absorption Spectrometry |
ASTM E 1184 : 2021 | Standard Practice for Determination of Elements by Graphite Furnace Atomic Absorption Spectrometry |
ASTM E 29 : 2013 : R2019 | Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications |
ASTM D 4790 : 2020 : REV A | Standard Terminology of Aromatic Hydrocarbons and Related Chemicals |
ASTM E 29 : 2002 | Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications |
ASTM D 1193 : 1977 : R1983 : EDT 1 | Standard Specification for Reagent Water |
ASTM D 4790 : 2007 | Standard Terminology of Aromatic Hydrocarbons and Related Chemicals |
ASTM E 691 : 2020 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM E 1184 : 2002 | Standard Practice for Electrothermal (Graphite Furnace) Atomic Absorption Analysis |
ASTM E 691 : 2019 : EDT 1 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM E 691 : 2023 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM D 1193 : 2006 : R2011 | Standard Specification for Reagent Water |
ASTM E 300 : 2003 : R2022 | Standard Practice for Sampling Industrial Chemicals |
ASTM D 4790 : 2023 | Standard Terminology of Aromatic Hydrocarbons and Related Chemicals |
ASTM D 6809 : 2002 : R2012 | Standard Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related Materials |
ASTM D 4790 : 1999 | Standard Terminology of Aromatic Hydrocarbons and Related Chemicals |
ASTM E 1184 : 2010 | Standard Practice for Determination of Elements by Graphite Furnace Atomic Absorption Spectrometry |
ASTM D 4790 : 2020 | Standard Terminology of Aromatic Hydrocarbons and Related Chemicals |
ASTM E 691 : 2022 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM E 691 : 2009 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM D 1193 : 1991 | Standard Specification for Reagent Water |
ASTM D 4790 : 2011 | Standard Terminology of Aromatic Hydrocarbons and Related Chemicals |
ASTM E 691 : 2021 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM D 4790 : 2014 | Standard Terminology of Aromatic Hydrocarbons and Related Chemicals |
ASTM D 6809 : 2002 | Standard Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related Materials |
ASTM E 300 : 2003 : R2017 | Standard Practice for Sampling Industrial Chemicals |
ASTM D 1193 : 1970 | Standard Specification For Reagent Water |
ASTM D 1193 : 2006 | Standard Specification for Reagent Water |
ASTM D 1193 : 1999 | Standard Specification for Reagent Water |
ASTM D 6809 : 2002 : R2007 | Standard Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related Materials |
ASTM D 1193 : 2006 : R2018 | Standard Specification for Reagent Water |
ASTM E 1184 : 1998 | Standard Practice for Electrothermal (Graphite Furnace) Atomic Absorption Analysis |
ASTM E 29 : 2022 | Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.