ASTM D 7773 : 2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Determination of Volatile Inorganic Acids (HCl, HBr, and HNO3 ) Using Filter Sampling and Suppressed Ion Chromatography
Hardcopy , PDF
23-10-2019
English
01-01-2012
CONTAINED IN VOL. 11.07, 2012 Defines the determination of the time-weighted average mass concentration of hydrogen chloride gas and hydrochloric acid mist, hydrogen bromide vapor and hydrobromic acid mist, and nitric acid vapor and mist in workplace air.
Committee |
D 22
|
DocumentType |
Test Method
|
Pages |
7
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1 This test method is intended for use in the determination of the time-weighted average mass concentration of hydrogen chloride gas and hydrochloric acid mist, hydrogen bromide vapor and hydrobromic acid mist, and nitric acid vapor and mist in workplace air. The samples are collected on an alkali-impregnated quartz fiber filter and analyzed by ion chromatography. The method is also appropriate for measuring short term exposures.
1.2 This test method assumes that air samples are collected using appropriate and applicable ASTM International standards for sampling of workplace air.
1.3 The procedure is targeted for occupational and environmental hygiene monitoring purposes.
1.4 No detailed operating instructions are provided because of differences among various makes and models of suitable instruments. Instead, the analyst shall follow the instructions provided by the manufacturer of the particular instrument. This standard does not address comparative accuracy of different devices or the precision between instruments of the same make and model.
1.5 The values stated in SI units are to be regarded as the standard.
1.6 The practice contains notes, which are explanatory and not part of mandatory requirements of the standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM D 4844 : 2016 : REDLINE | Standard Guide for Air Monitoring at Waste Management Facilities for Worker Protection |
ASTM D 8149 : 2017 | Standard Practice for Optimization, Calibration, and Validation of Ion Chromatographic Determination of Heteroatoms and Anions in Petroleum Products and Lubricants |
ASTM D 4844 : 2016 | Standard Guide for Air Monitoring at Waste Management Facilities for Worker Protection |
ASTM D 4840 : 1999 : R2018 : EDT 1 | Standard Guide for Sample Chain-of-Custody Procedures |
ASTM E 1370 : 2014 : REDLINE | Standard Guide for Air Sampling Strategies for Worker and Workplace Protection |
ASTM D 4840 : 1999 | Standard Guide for Sampling Chain-of-Custody Procedures |
ISO 7708:1995 | Air quality — Particle size fraction definitions for health-related sampling |
ASTM D 7035 : 2016 | Standard Test Method for Determination of Metals and Metalloids in Airborne Particulate Matter by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) |
ASTM E 1370 : 1996 | Standard Guide for Air Sampling Strategies for Worker and Workplace Protection |
ASTM D 1193 : 1977 : R1983 : EDT 1 | Standard Specification for Reagent Water |
ISO 1042:1998 | Laboratory glassware — One-mark volumetric flasks |
ISO 648:2008 | Laboratory glassware — Single-volume pipettes |
ASTM D 7035 : 2010 | Standard Test Method for Determination of Metals and Metalloids in Airborne Particulate Matter by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) |
ASTM E 1370 : 1996 : R2002 | Standard Guide for Air Sampling Strategies for Worker and Workplace Protection |
EN 1076:2009 | Workplace exposure - Procedures for measuring gases and vapours using pumped samplers - Requirements and test methods |
EN 482:2012+A1:2015 | Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents |
ASTM D 1193 : 2006 : R2011 | Standard Specification for Reagent Water |
ASTM D 5337 : 2011 : R2016 | Standard Practice for Flow Rate Adjustment of Personal Sampling Pumps |
ASTM E 1370 : 2014 | Standard Guide for Air Sampling Strategies for Worker and Workplace Protection |
ASTM D 1193 : 1991 | Standard Specification for Reagent Water |
ASTM D 5337 : 1997 | Standard Practice for Flow Rate for Calibration of Personal Sampling Pumps |
ASTM D 7035 : 2016 : REDLINE | Standard Test Method for Determination of Metals and Metalloids in Airborne Particulate Matter by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) |
ASTM D 5337 : 2011 | Standard Practice for Flow Rate for Calibration of Personal Sampling Pumps |
ASTM D 1193 : 1970 | Standard Specification For Reagent Water |
ASTM E 1370 : 1996 : R2008 | Standard Guide for Air Sampling Strategies for Worker and Workplace Protection |
ASTM D 1193 : 2006 | Standard Specification for Reagent Water |
ASTM D 1193 : 1999 | Standard Specification for Reagent Water |
ASTM D 5337 : 2004 | Standard Practice for Flow Rate for Calibration of Personal Sampling Pumps |
ASTM D 7035 : 2004 | Standard Test Method for Determination of Metals and Metalloids in Airborne Particulate Matter by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) |
ASTM D 1193 : 2006 : R2018 | Standard Specification for Reagent Water |