ASTM D 7652 : 2011
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Standard Test Method for Determination of Trace Hydrogen Sulfide, Carbonyl Sulfide, Methyl Mercaptan, Carbon Disulfide and Total Sulfur in Hydrogen Fuel by Gas Chromatography and Sulfur Chemiluminescence Detection (Withdrawn 2020)
Hardcopy , PDF
02-06-2020
English
01-03-2011
This test method describes a procedure primarily for the determination of hydrogen sulfide, carbonyl sulfide, methyl mercaptan, and carbon disulfide (Table 1) in hydrogen fuels for fuel cell vehicles (FCV) by gas chromatograph with sulfur chemiluminescence detection.
Committee |
D 03
|
DocumentType |
Test Method
|
Pages |
8
|
PublisherName |
American Society for Testing and Materials
|
Status |
Withdrawn
|
1.1 This test method describes a procedure primarily for the determination of hydrogen sulfide, carbonyl sulfide, methyl mercaptan, and carbon disulfide (Table 1) in hydrogen fuels for fuel cell vehicles (FCV) by gas chromatograph with sulfur chemiluminescence detection. The reporting limit is 0.02 ppbv (nanomole per mole as volume), based upon the analysis of a 500 mL hydrogen sample. The procedures described in this method were designed to satisfy sulfur contaminant determination requirements contained in SAE TIRJ2719 and the California Code of Regulations, CFR , Title 4, Division 9, Chapter 6, Article 8, Sections 4180 – 4181.
1.2 This test method can be extended to other sulfur species in hydrogen fuel that are eluted through a chromatographic column.
1.3 This test method can be modified to analyze all sulfur compounds present without chromatographic separation; thus, providing a total sulfur estimation without speciation (Appendix X1).
1.4 If any new sulfur compounds need to be analyzed in hydrogen fuel, the calibration or spiking sulfur standards must include these new compounds after their method detection limit study. In addition, no co-elution is allowed in the chromatographic analysis of the calibration standard containing both the newly added and the existing sulfur target compounds. If necessary, the chromatographic conditions may be modified to achieve this goal.
1.5 Although, primarily intended for determining sulfur in hydrogen used as a fuel for fuel cell or internal combustion engine powered vehicles, this test method can also be used to measure sulfur compounds in other gaseous fuels and gaseous matrices provided data quality objectives are satisfied.
1.6 The values stated in SI units are standard. The values stated in inch-pound units are for information only.
1.7 Mention of trade names in this standard does not constitute endorsement or recommendation for use. Other manufacturers of equipment or equipment models can be used.
1.8 Alternative Detectors—This test method is written primarily for the use of sulfur chemiluminescent detectors but other detectors can be used provided they can detect hydrogen sulfide, carbonyl sulfide, methyl mercaptan, and carbon disulfide at 0.02 ppbv in hydrogen and meet data quality objectives for the intended use.
1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For safety issues related to liquid nitrogen, refer to material safety data sheet (MSDS) from liquid nitrogen supplier.
SAE J 2719 : 2005(R2015) | HYDROGEN FUEL QUALITY FOR FUEL CELL VEHICLES |
BS ISO 14687-3:2014 | Hydrogen fuel. Product specification Proton exchange membrane (PEM) fuel cell applications for stationary appliances |
ISO 14687-2:2012 | Hydrogen fuel Product specification Part 2: Proton exchange membrane (PEM) fuel cell applications for road vehicles |
BS ISO 14687-2:2012 | Hydrogen fuel. Product specification Proton exchange membrane (PEM) fuel cell applications for road vehicles |
12/30240138 DC : 0 | BS ISO 14687-3 - HYDROGEN FUEL - PRODUCT SPECIFICATION - PART 3: PROTON EXCHANGE MEMBRANE (PEM) FUEL CELL APPLICATIONS FOR STATIONARY APPLIANCES |
ISO 14687-3:2014 | Hydrogen fuel Product specification Part 3: Proton exchange membrane (PEM) fuel cell applications for stationary appliances |
CFR 40(PTS100-149) : JUL 94 | PROTECTION OF ENVIRONMENT - ENVIRONMENTAL PROTECTION AGENCY |
ASTM D 5504 : 2012 : REDLINE | Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence |
ASTM D 7606 : 2017 | Standard Practice for Sampling of High Pressure Hydrogen and Related Fuel Cell Feed Gases |
ASTM D 5504 : 2008 | Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence |
ASTM D 5504 : 1998 | Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence |
ASTM D 5504 : 2001 | Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence |
ASTM D 5504 : 2001 : R2006 | Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence |
ASTM D 7606 : 2011 | Standard Practice for Sampling of High Pressure Hydrogen and Related Fuel Cell Feed Gases |
ASTM D 5504 : 2012 | Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence |
SAE J 2719 : 2005(R2015) | HYDROGEN FUEL QUALITY FOR FUEL CELL VEHICLES |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.