ASTM D 6522 : 2011 : REDLINE
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Determination of Nitrogen Oxides, Carbon Monoxide, and Oxygen Concentrations in Emissions from Natural Gas-Fired Reciprocating Engines, Combustion Turbines, Boilers, and Process Heaters Using Portable Analyzers
25-06-2020
English
01-12-2011
CONTAINED IN VOL. 11.03, 2017 Defines the determination of nitrogen oxides (NO and NO[2]), carbon monoxide (CO), and oxygen (O[2]) concentrations in controlled and uncontrolled emissions from natural gas-fired reciprocating engines, combustion turbines, boilers, and process heaters using portable analyzers with electrochemical sensors.
Committee |
D 22
|
DocumentType |
Redline
|
Pages |
12
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1 This test method covers the determination of nitrogen oxides (NO and NO2), carbon monoxide (CO), and oxygen (O2) concentrations in controlled and uncontrolled emissions from natural gas-fired reciprocating engines, combustion turbines, boilers, and process heaters using portable analyzers with electrochemical sensors. Due to the inherent cross sensitivities of the electrochemical cells, this test method should not be applied to other pollutants or emission sources without a complete investigation of possible analytical interferences and a comparative evaluation with EPA test methods.
1.1.1 The procedures and specifications of this method were originally developed during laboratory and field tests funded by the Gas Research Institute (GRI). Comparative emission tests were conducted only on natural gas-fired combustion sources. Subsequently, the United States Environmental Protection Agency (EPA) sponsored Environmental Technology Verification (ETV) program conducted further evaluations of electrochemical cell analyzers, which included laboratory tests and field tests on natural gas and diesel-fueled generators. The EPA has reviewed the ETV test results, published additional information, and provided technical input that has been considered in the update of this method.
1.2 This test method contains notes that are explanatory and are not part of the mandatory requirements of the standard.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.
I.S. EN 16738:2015 | EMISSION SAFETY OF COMBUSTIBLE AIR FRESHENERS - TEST METHODS |
BS EN 16738:2015 | Emission safety of combustible air fresheners. Test methods |
UNE-EN 16738:2016 | Emission safety of combustible air fresheners - Test methods |
DIN EN 16738:2016-04 | EMISSION SAFETY OF COMBUSTIBLE AIR FRESHENERS - TEST METHODS |
EN 16738:2015 | Emission safety of combustible air fresheners - Test methods |
ASTM D 3154 : 2014 : REDLINE | Standard Test Method for Average Velocity in a Duct (Pitot Tube Method) |
CFR 40(PTS61-80) : JUL 94 | PROTECTION OF ENVIRONMENT - ENVIRONMENTAL PROTECTION AGENCY |
CFR 40(PTS53-60) : JUL 92 | PROTECTION OF ENVIRONMENT - ENVIRONMENTAL PROTECTION AGENCY |