CONTAINED IN VOL. 11.03, 2015 Describes the evaluating of the performance of personal samplers of non-fibrous respirable aerosol.
Committee |
D 22
|
DocumentType |
Standard Practice
|
Pages |
9
|
ProductNote |
Reconfirmed EDT 1
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1 This practice covers the evaluation of the performance of personal samplers of non-fibrous respirable aerosol. The samplers are assessed relative to a specific respirable sampling convention. The convention is one of several that identify specific particle size fractions for assessing health effects of airborne particles. When a health effects assessment has been based on a specific convention it is appropriate to use that same convention for setting permissible exposure limits in the workplace and ambient environment and for monitoring compliance. The conventions, which define inhalable, thoracic, and respirable aerosol sampler ideals, have now been adopted by the International Standards Organization (Technical Report ISO TR 7708), the Comit Europen de Normalisation (CEN Standard EN 481), and the American Conference of Governmental Industrial Hygienists (ACGIH, Ref
1.2 This practice is complimentary to Test Method D 4532, which specifies a particular instrument, the 10-mm cyclone. The sampler evaluation procedures presented in this practice have been applied in the testing of the 10-mm cyclone as well as the Higgins-Dewell cyclone., Details on the evaluation have been recently published
1.3 A central aim of this practice is to provide information required for characterizing the uncertainty of concentration estimates from samples taken by candidate samplers. For this purpose, sampling accuracy data from the performance tests given here can be combined with information as to analytical and sampling pump uncertainty obtained externally. The practice applies principles of ISO GUM, expanded to cover situations common in occupational hygiene measurement, where the measurand varies markedly in both time and space. A general approach (
1.4 Units of the International System of Units (SI) are used throughout this practice and should be regarded as standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM D 7948 : 2014 : EDT 1 | Standard Test Method for Measurement of Respirable Crystalline Silica in Workplace Air by Infrared Spectrometry |
ASTM D 1356 : 2017 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ISO 7708:1995 | Air quality — Particle size fraction definitions for health-related sampling |
ASTM D 4532 : 2015 : REDLINE | Standard Test Method for Respirable Dust in Workplace Atmospheres Using Cyclone Samplers |
EN 481:1993 | Workplace atmospheres - Size fraction definitions for measurement of airborne particles |
EN 13205:2001 | Workplace atmospheres - Assessment of performance of instruments for measurement of airborne particle concentrations |
EN 1232:1997 | Workplace atmospheres - Pumps for personal sampling of chemical agents - Requirements and test methods |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.