Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM D 5126 : 2016 : EDT 1

Current

Current

The latest, up-to-date edition.

Standard Guide for Comparison of Field Methods for Determining Hydraulic Conductivity in Vadose Zone

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-07-2016

$112.95
Including GST where applicable

CONTAINED IN VOL. 04.08, 2018 Provides a review of the test methods for determining hydraulic conductivity in unsaturated soils and sediments.

Committee
D 18
DevelopmentNote
Supersedes ASTM D 5126/D5126M. (02/2017)
DocumentType
Guide
Pages
12
PublisherName
American Society for Testing and Materials
Status
Current
Supersedes

1.1This guide covers a review of the test methods for determining hydraulic conductivity in unsaturated soils and sediments. Test methods for determining both field-saturated and unsaturated hydraulic conductivity are described.

1.2Measurement of hydraulic conductivity in the field is used for estimating the rate of water movement through clay liners to determine if they are a barrier to water flux, for characterizing water movement below waste disposal sites to predict contaminant movement, and to measure infiltration and drainage in soils and sediment for a variety of applications. Test methods are needed for measuring hydraulic conductivity ranging from 1 × 10−2 to 1 × 10−8 cm/s, for both surface and subsurface layers, and for both field-saturated and unsaturated flow.

1.3For these field test methods a distinction is made between “saturated” (Ks) and “field-saturated” (Kfs) hydraulic conductivity. True saturated conditions seldom occur in the vadose zone except where impermeable layers result in the presence of perched water tables. During infiltration events or in the event of a leak from a lined pond, a “field-saturated” condition develops. True saturation does not occur due to entrapped air (1).2 The entrapped air prevents water from moving in air-filled pores that, in turn, may reduce the hydraulic conductivity measured in the field by as much as a factor of two compared to conditions when trapped air is not present (2). Field test methods should simulate the “field-saturated” condition.

1.4Field test methods commonly used to determine field-saturated hydraulic conductivity include various double-ring infiltrometer test methods, air-entry permeameter test methods, and borehole permeameter tests. Many empirical test methods are used for calculating hydraulic conductivity from data obtained with each test method. A general description of each test method and special characteristics affecting applicability is provided.

1.5Field test methods used to determine unsaturated hydraulic conductivity in the field include direct measurement techniques and various estimation methods. Direct measurement techniques for determining unsaturated hydraulic conductivity include the instantaneous profile (IP) test method and the gypsum crust method. Estimation techniques have been developed using borehole permeameter data and using data obtained from desorption curves (a curve relating water content to matric potential).

1.6The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.7All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026.

1.7.1The method used to specify how data are collected, calculated, or recorded in this standard is not directly related to the accuracy to which the data can be applied in design or other uses, or both. How one applies the results obtained using this standard is beyond its scope.

1.8This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.9This guide offers an organized collection of information or a series of options and does not recommend a specific course of action. This document cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of this guide may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of a project's many unique aspects. The word “Standard” in the title of this document means only that the document has been approved through the ASTM consensus process.

ASTM D 420 : 2018 Standard Guide for Site Characterization for Engineering Design and Construction Purposes
AASHTO R 13 : 2012 PRACTICE FOR CONDUCTING GEOTECHNICAL SUBSURFACE INVESTIGATIONS
ASCE 34 01 : 2001 STANDARD GUIDELINES FOR ARTIFICIAL RECHARGE OF GROUND WATER
ASTM F 1535 : 2000 Standard Test Method for Carrier Recombination Lifetime in Silicon Wafers by Noncontact Measurement of Photoconductivity Decay by Microwave Reflectance (Withdrawn 2003)

ASTM D 653 : 2007 Standard Terminology Relating to Soil, Rock, and Contained Fluids
ASTM D 3740 : 2012 Standard Practice for Minimum Requirements for Agencies Engaged in Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction
ASTM D 2434 : 2022 Standard Test Methods for Measurement of Hydraulic Conductivity of Coarse-Grained Soils
ASTM D 3740 : 2023 Standard Practice for Minimum Requirements for Agencies Engaged in Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction
ASTM D 3740 : 2019 Standard Practice for Minimum Requirements for Agencies Engaged in Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction
ASTM D 3740 : 2004 : REV A : EDT 1 Standard Practice for Minimum Requirements for Agencies Engaged in the Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction
ASTM D 3740 : 2008 Standard Practice for Minimum Requirements for Agencies Engaged in Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction
ASTM D 4643 : 2008 Standard Test Method for Determination of Water (Moisture) Content of Soil by Microwave Oven Heating
ASTM D 6026 : 2013 Standard Practice for Using Significant Digits in Geotechnical Data
ASTM D 3740 : 2012-06 PRACTICE FOR MINIMUM REQUIREMENTS FOR AGENCIES ENGAGED IN TESTING AND/OR INSPECTION OF SOIL AND ROCK AS USED IN ENGINEERING DESIGN AND CONSTRUCTION
ASTM D 6026 : 2006 Standard Practice for Using Significant Digits in Geotechnical Data
ASTM D 3740 : 1999 : REV C Standard Practice for Minimum Requirements for Agencies Engaged in the Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction
ASTM D 653 : 2024 Standard Terminology Relating to Soil, Rock, and Contained Fluids
ASTM D 3385 : 2003 Standard Test Method for Infiltration Rate of Soils in Field Using Double-Ring Infiltrometer
ASTM D 4643 : 2017 : REDLINE Standard Test Method for Determination of Water Content of Soil and Rock by Microwave Oven Heating
ASTM D 3385 : 2018 Standard Test Method for Infiltration Rate of Soils in Field Using Double-Ring Infiltrometer
ASTM D 653 : 2022 Standard Terminology Relating to Soil, Rock, and Contained Fluids
ASTM D 3385 : 2009-03 TEST METHOD FOR INFILTRATION RATE OF SOILS IN FIELD USING DOUBLE-RING INFILTROMETER
ASTM D 3385 : 1994 Standard Test Method for Infiltration Rate of Soils in Field Using Double-Ring Infiltrometer
ASTM D 4643 : 2017 Standard Test Method for Determination of Water Content of Soil and Rock by Microwave Oven Heating
ASTM D 653 : 2020 : EDT 1 Standard Terminology Relating to Soil, Rock, and Contained Fluids
ASTM D 2434 : 2019 Standard Test Method for Permeability of Granular Soils (Constant Head)
ASTM D 6026 : 1999 Standard Practice for Using Significant Digits in Geotechnical Data
ASTM D 3740 : 2011 Standard Practice for Minimum Requirements for Agencies Engaged in Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction
ASTM D 6026 : 2001 : EDT 1 Standard Practice for Using Significant Digits in Geotechnical Data
ASTM D 3740 : 2010 Standard Practice for Minimum Requirements for Agencies Engaged in Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction
ASTM D 653 : 2021 : REV A Standard Terminology Relating to Soil, Rock, and Contained Fluids
ASTM D 6026 : 1996 Standard Practice for Using Significant Digits in Geotechnical Data
ASTM D 3740 : 2004 : REV A Standard Practice for Minimum Requirements for Agencies Engaged in the Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction
ASTM D 3740 : 2001 Standard Practice for Minimum Requirements for Agencies Engaged in the Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction
ASTM D 653 : 2021 Standard Terminology Relating to Soil, Rock, and Contained Fluids
ASTM D 653 : 2021 : REV B Standard Terminology Relating to Soil, Rock, and Contained Fluids
ASTM D 3385 : 2009 Standard Test Method for Infiltration Rate of Soils in Field Using Double-Ring Infiltrometer
ASTM D 6026 : 1996 : EDT 1 Standard Practice for Using Significant Digits in Geotechnical Data
ASTM D 3740 : 2012 : REV A Standard Practice for Minimum Requirements for Agencies Engaged in Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction
ASTM D 3740 : 2003 Standard Practice for Minimum Requirements for Agencies Engaged in the Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction
ASTM D 2434 : 1968 : R2006 Standard Test Method for Permeability of Granular Soils (Constant Head) (Withdrawn 2015)
ASTM D 6026 : 2021 Standard Practice for Using Significant Digits and Data Records in Geotechnical Data
ASTM D 653 : 2024 : REV A Standard Terminology Relating to Soil, Rock, and Contained Fluids
ASTM D 6026 : 2001 Standard Practice for Using Significant Digits in Geotechnical Data
ASTM D 2434 : 1968 : R2000 Standard Test Method for Permeability of Granular Soils (Constant Head)
ASTM D 6026 : 2013 : REDLINE Standard Practice for Using Significant Digits in Geotechnical Data
ASTM D 4643 : 2000 Standard Test Method for Determination of Water (Moisture) Content of Soil by the Microwave Oven Method
ASTM D 3740 : 2004 Standard Practice for Minimum Requirements for Agencies Engaged in the Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction
ASTM D 653 : 2014 : REDLINE Standard Terminology Relating to Soil, Rock, and Contained Fluids

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more