Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM D 495 : 1999

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for High-Voltage, Low-Current, Dry Arc Resistance of Solid Electrical Insulation

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

31-12-2010

$122.77
Including GST where applicable

Committee
D 09
DocumentType
Test Method
Pages
10
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1 This test method covers, in a preliminary fashion, the differentiation among similar materials with respect to their resistance to the action of a high-voltage, low-current arc close to the surface of insulation, intending to form a conducting path therein or in causing the material to become conducting due to the localized thermal and chemical decomposition and erosion.

1.2 The usefulness of this test method is very severely limited by many restrictions and qualifications, some of which are described in the following paragraphs and in Section 5. Generally, this test method should not be used in material specifications. Whenever possible, alternative test methods should be used, and their development is encouraged.

1.3 This test method will not, in general, permit conclusions to be drawn concerning the relative arc resistance rankings of materials that may be subjected to other types of arcs: for example, high voltage at high currents, and low voltage at low or high currents (promoted by surges or by conducting contaminants).

1.4 The test method is intended, because of its convenience and the short time required for testing, for preliminary screening of material, for detecting the effects of changes in formulation, and for quality control testing after correlation has been established with other types of simulated service arc tests and field experience. Because this test method is usually conducted under clean and dry laboratory conditions rarely encountered in practice, the prediction of a material's relative performance in typical applications and in varying "clean to dirty" environments may be substantially altered (Note 1). Caution is urged against drawing strong conclusions without corroborating support of simulated service tests and field testing. Rather, this test method is useful for preliminary evaluation of changes in structure and composition without the complicating influence of environmental conditions, especially dirt and moisture.

Note 1-By changing some of the circuit conditions described herein it has been found possible to rearrange markedly the order of arc resistance of a group of organic insulating materials consisting of vulcanized fiber and of molded phenolic and amino plastics, some containing organic, and some inorganic, filler.

1.5 While this test method uses dry, uncontaminated specimen surfaces, Test Method D2132, Test Method D2303, and Test Method D3638 employ wet, contaminated specimen surfaces. Their use is recommended for engineering purposes and to assist in establishing some degree of significance to this test method for quality control purposes.

1.6 This test method is not applicable to materials that do not produce conductive paths under the action of an electric arc, or that melt or form fluid residues that float conductive residues out of the active test area thereby preventing formation of a conductive path.

1.7 The values stated in inch-pound units are to be regarded as the standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see 6.1.14, 6.1.19, Section 7, and 10.1.1.

ASTM D 1755 : 2015 Standard Specification for Poly(Vinyl Chloride) Resins
ASTM G 21 : 2015 Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi
ASTM D 1201 : 2013 Standard Specification for Thermosetting Polyester Molding Compounds
ASTM D 709 : 2017 Standard Specification for Laminated Thermosetting Materials
ASTM D 1039 : 2016 Standard Test Methods for Glass-Bonded Mica Used as Electrical Insulation
ASTM D 7745 : 2019 Standard Practice for Testing Pultruded Composites
ASTM D 229 : 2019 : EDT 1 Standard Test Methods for Rigid Sheet and Plate Materials Used for Electrical Insulation
ASTM D 1304 : 1999 : R2020 : EDT 1 Standard Test Methods for Adhesives Relative to Their Use as Electrical Insulation
ASTM D 705 : 1999 : R2020 Standard Specification for Urea-Formaldehyde Molding Compounds
ASTM D 710 : 2019 Standard Specification for Vulcanized Fibre Sheets, Rolls, Rods, and Tubes Used for Electrical Insulation
ASTM D 5948 : 2005 : R2020 Standard Specification for Molding Compounds, Thermosetting
ASTM D 704 : 1999 : R2020 Standard Specification for Melamine-Formaldehyde Molding Compounds
ASTM D 4000 : 2020 Standard Classification System for Specifying Plastic Materials
ASTM D 4101 : 2017 : EDT 1 Standard Classification System and Basis for Specification for Polypropylene Injection and Extrusion Materials

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more