ASTM C 1365 : 2006 : R2011

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Determination of the Proportion of Phases in Portland Cement and Portland-Cement Clinker Using X-Ray Powder Diffraction Analysis

Available format(s)

Hardcopy , PDF

Superseded date

07-09-2020

Superseded by

ASTM C 1365 : 2018

Language(s)

English

Published date

01-12-2011

$122.77
Including GST where applicable

CONTAINED IN VOL. 04.01, 2018 Defines direct determination of the proportion by mass of individual phases in portland cement or portland-cement clinker using quantitative X-ray (QXRD) analysis.

Committee
C 01
DocumentType
Test Method
Pages
10
ProductNote
Reconfirmed 2011
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1 This test method covers direct determination of the proportion by mass of individual phases in portland cement or portland-cement clinker using quantitative X-ray (QXRD) analysis. The following phases are covered by this standard: alite (tricalcium silicate), belite (dicalcium silicate), aluminate (tricalcium aluminate), ferrite (tetracalcium aluminoferrite), periclase (magnesium oxide), gypsum (calcium sulfate dihydrate), bassanite (calcium sulfate hemihydrate), anhydrite (calcium sulfate), and calcite (calcium carbonate).

1.2 This test method specifies certain general aspects of the analytical procedure, but does not specify detailed aspects. Recommended procedures are described, but not specified. Regardless of the procedure selected, the user shall demonstrate by analysis of certified reference materials (CRM's) that the particular analytical procedure selected for this purpose qualifies (that is, provides acceptable precision and bias) (see Note 1). The recommended procedures are ones used in the round-robin analyses to determine the precision levels of this test method.

Note 1—A similar approach was used in the performance requirements for alternative methods for chemical analysis in Test Methods C114.

1.3 The values stated in SI units shall be regarded as the standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazards, see Section 9.

ACI PRC-225:2023 Guide to the Selection and Use of Hydraulic Cements

ASTM C 150/C150M : 2017-04 SPECIFICATION FOR PORTLAND CEMENT
ASTM C 183/C183M : 2016 : REDLINE Standard Practice for Sampling and the Amount of Testing of Hydraulic Cement
ASTM C 670 : 2015 : REDLINE Standard Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more