ASTM C 1303/C1303M : 2022
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation
Hardcopy , PDF
24-11-2023
English
13-07-2022
Committee |
C 16
|
DocumentType |
Test Method
|
Pages |
22
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This test method covers a procedure for predicting the long-term thermal resistance (LTTR) of unfaced or permeably faced rigid gas-filled closed-cell foam insulations by reducing the specimen thickness to accelerate aging under controlled laboratory conditions (1-5) .2
Note 1:See Terminology, 3.2.1, for the meaning of the word aging within this standard.
1.2Rigid gas-filled closed-cell foam insulation includes all cellular plastic insulations manufactured with the intent to retain a blowing agent other than air.
1.3This test method is limited to unfaced or permeably faced, homogeneous materials. This method is applied to a wide range of rigid closed-cell foam insulation types, including but not limited to: extruded polystyrene, polyurethane, polyisocyanurate, and phenolic. This test method does not apply to impermeably faced rigid closed-cell foams or to rigid closed-cell bun stock foams.
Note 2:See Note 8 for more details regarding the applicability of this test method to rigid closed-cell bun stock foams.
1.4This test method utilizes referenced standard test procedures for measuring thermal resistance. Periodic measurements are performed on specimens to observe the effects of aging. Specimens of reduced thickness (that is, thin slices) are used to shorten the time required for these observations. The results of these measurements are used to predict the long-term thermal resistance of the material.
1.5The test method is given in two parts. The Prescriptive Method in Part A provides long-term thermal resistance values on a consistent basis that can be used for a variety of purposes, including product evaluation, specifications, or product comparisons. The Research Method in part B provides a general relationship between thermal conductivity, age, and product thickness.
1.5.1To use the Prescriptive Method, the date of manufacture must be known, which usually involves the cooperation of the manufacturer.
1.6The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8Table of Contents:
Section | |
Scope | 1 |
Reference Documents | 2 |
Terminology | 3 |
Summary of Test Method | 4 |
Significance and Use | 5 |
Part A: The Prescriptive Method | 6 |
Applicability | 6.1 |
Qualification Requirements | 6.1.1 |
Facing Permeability | 6.1.2 |
Apparatus | 6.2 |
Sampling | 6.3 |
Schedule | 6.3.1 |
Specimen Preparation | 6.4 |
Goal | 6.4.1 |
Schedule | 6.4.2 |
Replicate Test Specimen Sets | 6.4.3 |
Specimen Extraction | 6.4.4 |
Slice Flatness | 6.4.5 |
Slice Thickness | 6.4.6 |
Stack Composition | 6.4.7 |
Storage Conditioning | 6.5 |
Test Procedure | 6.6 |
Thermal Resistance Measurement Schedule | 6.6.1 |
Thermal Resistance Measurements | 6.6.2 |
Product Density | 6.6.3 |
Calculations | 6.7 |
Part B: The Research Method | 7 |
Background | 7.1 |
TDSL Apparatus | 7.2 |
Sampling Schedule | 7.3 |
Specimen Preparation | 7.4 |
Storage Conditioning | 7.5 |
Test Procedure | 7.6 |
Calculations | 7.7 |
Reporting | 8 |
Reporting for Part A, the Prescriptive Method | 8.1 |
Reporting for Part B, the Research Method | 8.2 |
Precision and Bias | 9 |
Keywords | 10 |
Mandatory Information – Qualification | Annex A1 |
Specimen Preparation | A1.1 |
Homogeneity Qualification | A1.2 |
Thermal Conductivity Equivalence Test Procedure | A1.3 |
Alternate Product Thickness Qualification | A1.4 |
Example Calculations | A1.5 |
Mandatory Information-Preparation of Test Specimens for Spray-Foam Products | Annex A2 |
Effect Of TDSL | Appendix X1 |
History of the Standard | Appendix X2 |
Theory of Foam Aging | Appendix X3 |
References |
1.9This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM C 1289 : 2023 : REV A | Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board |
ASTM C 591 : 2021 | Standard Specification for Unfaced Preformed Rigid Cellular Polyisocyanurate Thermal Insulation |
ASTM C 1126 : 2019 | Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation |
ASTM C 1289 : 2022 | Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board |
ASTM C 1029 : 2020 | Standard Specification for Spray-Applied Rigid Cellular Polyurethane Thermal Insulation |
ASTM C 177 : 2019 | Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus |
ASTM C 591 : 2022 | Standard Specification for Unfaced Preformed Rigid Cellular Polyisocyanurate Thermal Insulation |
ASTM C 1289 : 2023 : REV A | Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board |
ASTM C 1289 : 2022 | Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board |
ASTM C 578 : 2019 | Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation |
ASTM C 578 : 2022 | Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation |
ASTM C 1289 : 2023 | Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board |
ASTM C 1289 : 2022 : REV A | Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board |
ASTM C 177 : 2019 : EDT 1 | Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus |
ASTM C 578 : 2023 | Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.