ASTM C 1289 : 2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board
Hardcopy , PDF
11-11-2014
English
10-06-2002
Committee |
C 16
|
DocumentType |
Standard
|
Pages |
8
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1 This specification covers the general requirements for faced thermal insulation boards composed of rigid cellular polyisocyanurate surfaced with other materials. The insulation boards are intended for use at temperatures between -40 and 200oF (40 and 93oC). This specification does not cover cryogenic applications. Consult the manufacturer for specific recommendations and properties in cryogenic conditions. For specific applications, the actual temperature limits shall be agreed upon by the manufacturer and the purchaser.
1.2 This standard is intended to apply to rigid cellular polyurethane-modified polyisocyanurate thermal insulation board products that are commercially acceptable as non-structural panels useful in building construction. The term polyisocyanurate encompasses the term polyurethane. For engineering and design purposes, users should follow specific product information provided by board manufacturers regarding physical properties, system design considerations and installation recommendations.
1.3 The use of thermal insulation materials covered by this specification may be regulated by building codes, or other agencies that address fire performance, or both. The fire performance of the material should be addressed through standard fire test methods established by the appropriate governing documents.
1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only and may be approximate. For conversion to metric units other than those contained in this standard, refer to IEEE/ASTM SI 10.
1.5 The following safety hazards caveat pertains only to the test methods, Section 11, in this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM C 1558 : 2019 | Standard Guide for Development of Standard Data Records for Computerization of Thermal Transmission Test Data for Thermal Insulation |
ASTM E 2568 : 2017 : REV A | Standard Specification for PB Exterior Insulation and Finish Systems |
ASTM C 1535 : 2005 : R2017 | Standard Practice for Application of Exterior Insulation and Finish Systems Class PI |
ASTM D 7793 : 2017 | Standard Specification for Insulated Vinyl Siding |
ASTM C 728 : 2017 : REV A | Standard Specification for Perlite Thermal Insulation Board |
ASTM C 1696 : 2016 | Standard Guide for Industrial Thermal Insulation Systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.