ASTM A 239 : 2014 : REDLINE
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Standard Practice for Locating the Thinnest Spot in a Zinc (Galvanized) Coating on Iron or Steel Articles,
21-05-2021
English
01-05-2014
CONTAINED IN VOL. 01.06, 2017 Describes the procedure for locating, by the use of a solution of copper sulfate, the thinnest spot in a zinc coating (hot dipped, electroplated, or sprayed) on iron or steel articles that are coated after the shape is produced by casting, drawing, pressing, or other forming methods.
Committee |
A 05
|
DevelopmentNote |
Supersedes ASTM A 191 and ASTM A 208. (04/2002)
|
DocumentType |
Redline
|
Pages |
5
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
1.1This practice covers the procedure for locating, by the use of a solution of copper sulfate, the thinnest spot in a zinc coating (hot dipped, electroplated, or sprayed) on iron or steel articles that are coated after the shape is produced by casting, drawing, pressing, or other forming methods. Examples are: electrical metallic tubing and rigid conduit pipe, castings and forgings, and structural steel; on special hardware, such as poleline, builder's, and farm implement hardware; bolts, nuts, screws, and other miscellaneous general hardware.
1.2The use of this practice with zinc coating deposited through different processes (such as hot dipped, electroplated, or sprayed) requires caution in interpretation since the end point may vary considerably between different zinc-coating systems.
1.3Excluded from this practice is sheet steel from hot-dip or electrocoating lines as the sheet products are normally subject to additional forming after the coating process. Also excluded from this practice are all zinc-coated wire and wire products either continuously or batch coated before or after forming. Warning—Past research (dating from around 1963) has indicated that this practice can be influenced by operator technique. Variations can be due to the difference in hand pressure used to wipe the sample or the inability of the operator to recognize the end point.
1.4This technique removes the zinc coating on the surface of the part being examined. This coating removal makes the part or article unusable after testing. This technique may not be suitable for parts fabricated into their final configuration, since they will not be acceptable after testing.
1.5The results of this practice should not be used to predict the service life of the galvanized coating. Other factors such as location of the thinnest spot, orientation of the part in service, and specific environmental conditions will also affect the service life.
1.6The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standards | Relationship |
UNE 7183:1964 | Identical |
MIL C 55036 : A | CABLE, TELEPHONE WM-130( )/G |
QQ-S-781 Revision H:1974 | STRAPPING, STEEL, AND SEALS |
CSA C22.2 No. 203.1 : 2014 | MANUFACTURED WIRING SYSTEMS |
SAE J 1648 : 2013 | PROTECTIVE COATINGS FOR FASTENERS |
CSA C22.2 No. 62 : 1993 : R2008 | SURFACE RACEWAY SYSTEMS |
ASTM D 3953 : 2015 : REDLINE | Standard Specification for Strapping, Flat Steel and Seals |
I.S. EN ISO 10308:2006 | METALLIC COATINGS - REVIEW OF POROSITY TESTS |
ANSI C80.6 : 2005 | ELECTRICAL INTERMEDIATE METAL CONDUIT (EIMC) |
CSA C22.2 No. 45.1 :2007 | ELECTRICAL RIGID METAL CONDUIT - STEEL |
CSA C22.2 No. 45.1 : 2007 : INC : UPD 1 : 2010 | ELECTRICAL RIGID METAL CONDUIT - STEEL |
CSA C22.2 No. 45.1 : 2007 : FR | ELECTRICAL RIGID METAL CONDUIT - STEEL |
ASTM F 2408 : 2016 : REDLINE | Standard Specification for Ornamental Fences Employing Galvanized Steel Tubular Pickets |
CSA C22.2 No. 83.1 : 2007 | ELECTRICAL METALLIC TUBING - STEEL |
CSA C22.2 No. 83.1 : 2007 : INC : UPD 1 : 2012 : R201200 | ELECTRICAL METALLIC TUBING - STEEL |
MIL-C-82403 Base Document:1965 | CABLE, SUBMARINE, POWER, CONTROL AND COMBINATION |
ASTM A 880 : 1995 | Standard Practice for Criteria for Use in Evaluation of Testing Laboratories and Organizations for Examination and Inspection of Steel, Stainless Steel, and Related Alloys (Withdrawn 2004) |
C22.2 NO. 45.1-07 (R2017) | Electrical Rigid Metal Conduit - Steel (Tri-National standard, with UL 6 and NMX-J-534-ANCE-2007) |
CSA C22.2 No. 45.1 : 2007 : INC : UPD 2 : 2014 : R201200 | ELECTRICAL RIGID METAL CONDUIT - STEEL |
CSA C22.2 No. 203.2 : 2014 | POWERED TABLE SYSTEMS FOR RESIDENTIAL AND COMMERCIAL USE |
CSA C22.2 No. 62 : 1993 : R2013 | SURFACE RACEWAY SYSTEMS |
EN ISO 10308:2006 | Metallic coatings - Review of porosity tests (ISO 10308:2006) |
MIL-DTL-55036 Revision C:2011 | CABLE, TELEPHONE, WM - 130()/G |
CSA C22.2 No. 45.1 : 2007 : INC : UPD 1 : 2010 : R2012 | ELECTRICAL RIGID METAL CONDUIT - STEEL |
CSA C22.2 No. 126 : 0 | CABLE TRAY SYSTEMS |
CSA C22.2 No. 62 : 1993 | SURFACE RACEWAY SYSTEMS |
DIN EN ISO 10308:2006-04 | METALLIC COATINGS - REVIEW OF POROSITY TESTS |
BS EN ISO 10308:2006 | Metallic coatings. Review of porosity tests |
ISO 10308:2006 | Metallic coatings Review of porosity tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.