AS/NZS 61558.2.6:2001
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Safety of power transformers, power supply units and similar Particular requirements for safety isolating transformers for general use (IEC 61558-2-6:1997, MOD)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
29-05-2024
11-06-2001
Specifies safety requirements for approval and test purposes for safety isolating transformers. This Standard is an adoption with national modifications and contains the full text of IEC 61558-2-6:1997.
Committee |
EL-002
|
DocumentType |
Standard
|
ISBN |
0 7337 4073 1
|
Pages |
10
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
Replacement:This part 2 of IEC 61558 applies to stationary or portable, single-phase or polyphase, air-cooled safety isolating transformers, associated or otherwise, having a rated supply voltage not exceeding 1000 V a.c. and rated frequency not exceeding 500 Hz, the rated output not exceeding:– 10 kVA for single-phase transformers;– 16 kVA for polyphase transformers.This standard is also applicable to safety isolating transformers without limitation of the rated output; however such transformers are considered as special transformers and are subjected to an agreement between the purchaser and the supplier.The no-load output voltage and the rated output voltage does not exceed:50 V a.c. r.m.s. and/or 120 V ripple-free d.c.between conductors or between any conductor and earth.This standard is applicable to dry type transformers. The windings may be encapsulated or non-encapsulated.
AS 3108 first published in Australia in part as AS C126-1939.
Second edition 1958.
AS C167 first published 1962.
Revised and redesignated AS 3167-1981 (withdrawn 1987).
AS C126-1958 revised and redesignated AS 3126-1981 (withdrawn 1989).
AS 3126-1981 and AS 3167-1981 revised and redesignated AS 3108.1-1984, AS 3108.2-1984 and AS 3108.3-1984.
Revised, amalgamated and redesignated AS 3108-1990.
First published in New Zealand as NZS/AS 3108:1990.
Jointly revised and designated as Joint Standard AS/NZS 3108:1994.
Jointly revised and redesignated in part as AS/NZS 61558.2.6:2001.
AS/NZS 3112:2000 | Approval and test specification - Plugs and socket-outlets |
AS 1621.3.1-1988 | Pressure-sensitive adhesive electrical tapes Plasticized polyvinyl chloride tapes with non-thermosetting adhesive |
AS 1621.3.3-1988 | Pressure-sensitive adhesive electrical tapes Polyester film tapes (PETP) with non-thermosetting adhesive |
AS 1621.3.2-1988 | Pressure-sensitive adhesive electrical tapes Polyester film tapes (PETP) with thermosetting adhesive |
AS 2768-1985 | Electrical insulating materials - Evaluation and classification based on thermal endurance |
AS/NZS 3250:1995 | Approval and test specification - Mains operated electronic and related equipment for household and similar general use |
AS 2752-1985 | Preferred numbers and their use |
AS 1621.2-1988 | Pressure-sensitive adhesive electrical tapes Methods of test |
AS/NZS 3947.7.1:2001 | Low-voltage switchgear and controlgear Ancillary equipment - Terminal blocks for copper conductors |
AS/NZS 3191:1996 | Approval and test specification - Electric flexible cords |
AS/NZS 4898:1997 | Approval and test specification - Circuit-breakers for overcurrent protection for household and similar installations |
AS 2005.21.1-1990 | Low voltage fuses - Fuses with enclosed fuse-links Supplementary requirements for fuses for use by authorized persons (Fuses mainly for industrial application) - Standardized fuse systems - Fuses with fuse-links with blade contacts |
AS 2005.20-1990 | Low voltage fuses - Fuses with enclosed fuse-links Supplementary requirements for fuses for use by authorized persons (Fuses mainly for industrial application) - Common requirements |
AS 3109.1-1987 | Approval and test specification - Appliance couplers for household and similar general purposes - General requirements |
AS/NZS 3000:2000 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS 1104-1978 | Informative symbols for use on electrical and electronic equipment |
AS/NZS 60998.1:1998 | Connecting devices for low voltage circuits for household and similar purposes General requirements |
AS/NZS 4695.707:1996 | Fire hazard testing of electrotechnical products Methods of test for the determination of the flammability of solid electrical insulating materials when exposed to an igniting source |
AS/NZS 4695.2.11:1996 | Fire hazard testing of electrotechnical products Test methods - Glow-wire end-product test and guidance |
AS 2374.1-1997 | Power transformers General |
AS/NZS 60998.2.2:1998 | Connecting devices for low voltage circuits for household and similar purposes Particular requirements for connecting devices as separate entities with screwless-type clamping units |
AS/NZS 4695.2.10:1996 | Fire hazard testing of electrotechnical products Test methods - Glow-wire test methods - General |
AS 1621.1-1988 | Pressure-sensitive adhesive electrical tapes - General requirements |
AS/NZS 60998.2.1:1998 | Connecting devices for low voltage circuits for household and similar purposes Particular requirements for connecting devices as separate entities with screw-type clamping units |
AS/NZS 3139.1:1995 | Approval and test specification - Switches for appliances General requirements |
AS 1939-1990 | Degrees of protection provided by enclosures for electrical equipment (IP Code) |
AS 1621.3.5-1988 | Pressure-sensitive adhesive electrical tapes Cellulosic paper tapes with thermosetting adhesive |
AS 1621.3.4-1988 | Pressure-sensitive adhesive electrical tapes Cellulosic paper tapes, creped, with thermosetting adhesive |
AS/NZS 4695.112:1996 | Fire hazard testing of electrotechnical products Method for determining the comparative and the proof tracking indices of solid insulating materials under moist conditions |
AS 2005.30-1991 | Low voltage fuses - Fuses with enclosed fuse-links - Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) |
AS 2703-2008 | Vehicle loop detector sensors |
AS 2865-2009 | Confined spaces |
AS/NZS 3439.4:2009 | Low-voltage switchgear and controlgear assemblies Particular requirements for assemblies for construction sites (ACS) |
AS/NZS 3197:2005 | Approval and test specification - Portable electrical control or conditioning devices |
AS/NZS 3004.2:2008 | Electrical installations - Marinas and recreational boats Recreational boats installations |
AS/NZS 60598.2.22:2005 | Luminaires Particular requirements - Luminaires for emergency lighting (IEC 60598-2 22, Ed. 3.1(2002) MOD) |
AS/NZS 4879.1:2008 | Performance of transformers and electronic step-down convertors for ELV lamps Test method - Energy performance (Reconfirmed 2017) |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 3136:2001 | Approval and test specification - Electrical equipment for spa and swimming pools |
AS/NZS 3004.1:2008 | Electrical installations - Marinas and recreational boats Marinas |
AS 3533.2-2009 | Amusement rides and devices Operation and maintenance |
AS 3533.1-2009 | Amusement rides and devices Design and construction |
AS/NZS 3100:2002 | Approval and test specification - General requirements for electrical equipment |
AS/NZS 3100:2009 | |
AS 2832.3-2005 | Cathodic protection of metals Fixed immersed structures |
AS 2832.5-2008 | Cathodic protection of metals Steel in concrete structures |
AS/NZS 3350.1:2002 | Safety of household and similar electrical appliances General requirements (IEC 60335-1:1991, MOD) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.