AS/NZS 61558.2.3:2001

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Safety of power transformers, power supply units and similar devices Particular requirements for ignition transformers for gas and oil burners (IEC 61558-2-3:1999, IDT)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

29-07-2024

Superseded by

AS/NZS 61558.2.3:2011

Language(s)

English

Published date

01-01-2001

Preview
$106.99
Including GST where applicable

1 - AS/NZS 61558.2.3:2001 SAFETY OF POWER TRANSFORMERS, POWER SUPPLY UNITS AND SIMILAR DEVICES - PARTICULAR REQUIREMENTS FOR IGNI
4 - CONTENTS
7 - PREFACE
9 - 1 Scope
9 - 2 Normative references
10 - 3 Definitions
10 - 4 General requirements
10 - 5 General notes on tests
10 - 6 Rating
11 - 7 Classification
11 - 8 Marking and other information
13 - 9 Protection against accessibility to hazardous live parts
13 - 10 Change of input voltage setting
13 - 11 Output voltage and output current under load
14 - 12 No-load output voltage
14 - 13 Short-circuit voltage
14 - 14 Heating
14 - 15 Short-circuit and overload protection
15 - 16 Mechanical strength
15 - 17 Protection against harmful ingress of dust, solid objects and moisture
15 - 18 Insulation resistance and electric strength
16 - 19 Construction
17 - 20 Components
17 - 21 Internal wiring
17 - 22 Supply connection and other external flexible cables or cords
17 - 23 Terminals for externals conductors
17 - 24 Provision for protective earthing
17 - 25 Screws and connections
17 - 26 Creepage distances, clearances and distances through insulation
18 - 27 Resistance to heat, abnormal heat, fire and tracking
18 - 28 Resistance to rusting
20 - Annexes
20 - Annex C - Creepage distances and clearances – Material group II
20 - Annex D - Creepage distances and clearances – Material group I

Specifies general safety requirements for approval and test purposes for ignition transformers for gas and oil burners. This Standard is an adoption with national modifications and contains the full text of IEC 61558-2-3:1999.

Committee
EL-002
DocumentType
Standard
ISBN
0 7337 4420 6
Pages
12
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Replacement:This International Standard deals with all aspects of safety such as electrical, thermal and mechanical aspects.This part of IEC 61558 AS/NZS 61558 applies to fixed single-phase air-cooled (natural or forced) associated transformers (incorporated or not) used in the ignition system of gas and oil burners, having a rated supply voltage not exceeding 1 000 V a.c. and a rated frequency not exceeding 500 Hz. The rated output current does not exceed 500 mA a.c.NOTE 1 Due to the national safety law, in Japan the rated output current does not exceed 50 mA.The no-load output voltage and the rated no-load output voltage does not exceed 15 000 V a.c.This standard applies to transformers where double or reinforced insulation between circuits is not required by the installation rules or by the appliance specification.NOTE 2 The transformers are intended to be associated with equipment to provide voltages different from the supply voltage for the functional requirement of the equipment. The safety insulation may be provided (or completed) by other features of the equipment, such as the body.This standard is applicable to dry-type transformers. The windings may be encapsulated or non encapsulated.NOTE 3 For transformers filled with liquid dielectric or pulverised material, such as sand, additional requirements are under consideration.NOTE 4 Attention is drawn to the fact that for transformers intended to be used in tropical countries special requirements may be necessary; for the purposes of this standard, Australia and New Zealand are not considered to be tropical; in locations where special environmental conditions prevail, particular requirements may be necessary.This standard also applies to transformers incorporating electronic circuits. This standard does not apply to external circuits and their components intended to be connected to the input and output terminals or socket-outlets of the transformer.NOTE 5 Electronic ignition transformers are under consideration.

Standards Relationship
IEC 61558-2-3:1999 Identical

First published as AS/NZS 61558.2.3:2001.

AS 2703-2008 Vehicle loop detector sensors
AS/NZS 4836:2011 Safe working on or near low-voltage electrical installations and equipment
AS 2865-2009 Confined spaces
AS/NZS 3439.4:2009 Low-voltage switchgear and controlgear assemblies Particular requirements for assemblies for construction sites (ACS)
AS/NZS 3197:2005 Approval and test specification - Portable electrical control or conditioning devices
AS/NZS 3004.2:2008 Electrical installations - Marinas and recreational boats Recreational boats installations
AS 2144:2014 Traffic signal lanterns
AS/NZS 3105:2014 Approval and test specification - Electrical portable outlet devices
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 2832.3-2005 Cathodic protection of metals Fixed immersed structures
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) Electrical installations (known as the Australian/New Zealand Wiring Rules)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more