Safety of power transformers, power supply units and similar devices Particular requirements for transformers for construction sites (IEC 61558-2-23:2000, MOD)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
23-04-2024
English
12-11-2001
Specifies general safety requirements for approval and test purposes for transformers for construction sites. This Standard is an adoption with national modifications and contains the full text of IEC 61558-2-23:2000.
Committee |
EL-002
|
DocumentType |
Standard
|
ISBN |
0 7337 4426 5
|
Pages |
16
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
Replacement:This International Standard deals with all aspects of safety such as electrical, thermal and mechanical.This part of IEC 61558 AS/NZS 61558 applies to stationary or portable single-phase or poly-phase air-cooled (natural or forced) independent or associated, isolating or safety isolating transformers intended for use on construction sites, having a rated supply voltage not exceeding 1 000 V a.c., and a rated frequency not exceeding 500 Hz.The rated output should not exceed: 25 kVA for single-phase transformers; 40 kVA for poly-phase transformers.Isolating transformers for construction sites should have a no-load output voltage and a rated output voltage exceeding 50 V a.c. and not exceeding 250 V a.c.Safety isolating transformers for construction sites should have a no-load output voltage and a rated output voltage not exceeding 50 V a.c.NOTE This standard is applicable to transformers for the supply of electricity in locations as specified in IEC 60364-7-704. The latter also specifies the protection by using an earthed midpoint or starpoint of the output winding.Transformers for construction sites are to be used when required by the installation rules or by the appliance specification for protection purposes.When the transformers are incorporated into low-voltage switchgear and controlgear assemblies for construction sites as specified in IEC 60439-4, the additional requirements of IEC 60439-4 will apply to the assembly.This standard is applicable to dry-type transformers. The windings may be encapsulated or non-encapsulated.NOTE 1 For transformers filled with liquid dielectric or pulverized material, such as sand, additional requirements are under consideration.NOTE 2 Attention is drawn to the fact that for transformers intended to be used in tropical countries, special requirements may be necessary; for the purposes of this standard, Australia and New Zealand are not considered to be tropical; in locations where special environmental conditions prevail, particular requirements may be necessary.This standard also applies to transformers incorporating electronic circuits. This standard does not apply to external circuits and their components intended to be connected to the input and output terminals or socket-outlets of the transformer.
First published as AS/NZS 61558.2.23:2001.
AS/NZS 3012:2010 | Electrical installations - Construction and demolition sites |
AS 2703-2008 | Vehicle loop detector sensors |
AS/NZS 4836:2011 | Safe working on or near low-voltage electrical installations and equipment |
AS 2865-2009 | Confined spaces |
AS/NZS 3439.4:2009 | Low-voltage switchgear and controlgear assemblies Particular requirements for assemblies for construction sites (ACS) |
AS/NZS 3197:2005 | Approval and test specification - Portable electrical control or conditioning devices |
AS/NZS 3004.2:2008 | Electrical installations - Marinas and recreational boats Recreational boats installations |
AS 2144:2014 | Traffic signal lanterns |
AS/NZS 3105:2014 | Approval and test specification - Electrical portable outlet devices |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 3012:2003 | Electrical installations - Construction and demolition sites |
AS 2832.3-2005 | Cathodic protection of metals Fixed immersed structures |
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) | Electrical installations (known as the Australian/New Zealand Wiring Rules) |