AS/NZS 60598.2.25:2001
Current
The latest, up-to-date edition.
Luminaires Particular requirements - Luminaires for use in clinical areas of hospitals and health care buildings (IEC 60598.2.25:1994, MOD) (Reconfirmed 2013) (Reconfirmed 2024)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
29-11-2001
Specifies requirements for luminaires for use with tungsten filament, fluorescent and other discharge lamps in supply voltages up to 1000V for use in clinical areas, where medical treatment, examination and medical care takes place in hospitals and health care buildings. It does not apply to medical electrical equipment containing a light source as defined in Clause 2.2.15 of IEC 60601.
Committee |
EL-041
|
DocumentType |
Standard
|
ISBN |
0 7337 4149 5
|
Pages |
12
|
ProductNote |
Reconfirmed 17/10/2013This standard has been reconfirmed in Australia in 2013 and remains current in New Zealand. Reconfirmation Notice 17/10/2013
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This section of IEC 60598-2 AS/NZS 60598.2 details specific requirements for luminaires for use with tungsten filament, fluorescent and other discharge lamps on supply voltages not exceeding 1 000 V for use in clinical areas in which medical treatment, examination and medical care takes place in hospitals and health care buildings.This standard does not apply to medical electrical equipment, as defined in 2.2.15 of IEC 60601-1 AS/NZS 3200.1, containing a light source.NOTE 1 - Subclause 2.2.15 of IEC 60601-1 AS/NZS 3200.1 states: Electrical equipment, provided with not more than one connection to a particular supply mains and intended to diagnose, treat, or monitor the patient under medical supervision and which makes physical or electrical contact with the patient and/or transfers energy to or from the patient and/or detects such energy transfer to or from the patient.This standard does not apply to luminaires for emergency lighting and luminaires for general illumination in non-clinical areas (e.g. offices).NOTE 2 - For these luminaire types, reference should be made to other sections of IEC 60598-2 AS/NZS 60598.2This standard does not apply to luminaires or parts of luminaires which are designed to be sterilized by the autoclave process and luminaires for operating tables.
Standards | Relationship |
IEC 60598-2-25:1994 | Identical |
First published as AS/NZS 60598.2.25:2001.
Reissued incorporating Amendment No 1 (June 2024).
AS/NZS 60598.2.2:2001 | Luminaires Particular requirements - Recessed luminaires (IEC 60598-2-2:1996, MOD) |
AS/NZS 60598.2.4:1998 | Luminaires Particular requirements - Portable general purpose luminaires |
AS/NZS 3200.1.0-1998 | Medical electrical equipment General requirements for safety - Parent Standard |
AS/NZS 60598.2.6:1998 | Luminaires Particular requirements - Luminaires with built-in transformers or convertors for filament lamps (Reconfirmed 2013) |
AS/NZS 60598.2.10:1998 | Luminaires Particular requirements - Portable child-appealing luminaires (Reconfirmed 2013) |
AS/NZS 3200.1.3:1996 | Approval and test specification - Medical electrical equipment General requirements for safety - Collateral Standard: Requirements for radiation protection in diagnostic X-ray equipment |
AS/NZS 3200.1.4:1997 | Approval and test specification - Medical electrical equipment General requirements for safety - Collateral Standard: Programmable electrical medical systems |
AS/NZS 60598.2.18:1998 | Luminaires Particular requirements - Luminaires for swimming pools and similar applications (Reconfirmed 2013) |
AS/NZS 60598.2.1:1998 | Luminaires Particular requirements - Fixed general purpose luminaires (Reconfirmed 2013) |
AS/NZS 60598.2.20:1998 | Luminaires Particular requirements - Lighting chains |
AS/NZS 60598.1:2001 | Luminaires General requirements and tests (IEC 60598.1:1996, MOD) |
AS/NZS 60598.2.19:2001 | Luminaires Particular requirements - Air handling luminaires (Safety requirements) (IEC 60598.2.19:1981, MOD) (Reconfirmed 2013) (Reconfirmed 2024) |
AS/NZS 60598.2.8:1998 | Luminaires Particular requirements - Handlamps |
AS/NZS 3200.1.1:1995 | Approval and test specification - Medical electrical equipment General requirements for safety - Collateral Standard: Safety requirements for medical electrical systems |
AS/NZS 3200.1.2:1995 | Approval and test specification - Medical electrical equipment General requirements for safety - Collateral Standard: Electromagnetic compatibility - Requirements and tests |
AS/NZS 3004.2:2008 | Electrical installations - Marinas and recreational boats Recreational boats installations |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 60598.1:2013 | Luminaires General requirements and tests (IEC 60598-1, Ed. 7.0 (2008) MOD) |
AS/NZS 60079.15:2011 | Explosive atmospheres Equipment protection by type of protection 'n' |
AS/NZS 60598.1:2003 | Luminaires General requirements and tests (IEC 60598-1:2003, MOD) |
AS/NZS 4782.1:2004 | Double-capped fluorescent lamps - Performance specifications General (IEC 60081:2000, MOD) (Reconfirmed 2016) |
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.