AS/NZS 60598.1:2003
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Luminaires General requirements and tests (IEC 60598-1:2003, MOD)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
23-06-2021
English
29-09-2003
Specifies general and safety requirements for luminaires with related tests for mechanical and electrical constructions. This document is reproduced fromthe Lumex WG draft Edition 6 of IEC 60598-1 and varied for Australian/New Zealand conditions.
Committee |
EL-041
|
DocumentType |
Standard
|
ISBN |
0 7337 5464 3
|
Pages |
177
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This part 1 of the Standard AS/NZS 60598 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this standard cover: classification, marking, mechanical construction and electrical construction. Each section of this part 1 should be read in conjunction with this section 0 and with other relevant sections to which reference is made. Each section of IEC 60598-2 details requirements for a particular type of luminaire or group of luminaires on supply voltages not exceeding 1 000 V. These sections are published separately for ease of revision and additional sections will be added as and when a need for them is recognized. Attention is drawn to the fact that this part 1 covers all aspects of safety (electrical, thermal and mechanical). The presentation of photometric data for luminaires is under consideration by the International Commission on Illumination (CIE) and is not, therefore, included in this part 1. Requirements are included in this part 1 for luminaires incorporating ignitors with nominal peak values of the voltage pulse not exceeding those of table 11.2. The requirements apply to luminaires with ignitors built into ballasts and to luminaires with ignitors separate from ballasts. For luminaires with ignitors built into lamps, the requirements are under consideration. Requirements for semi-luminaires are included in this part 1. In general this part 1 covers safety requirements for luminaires. The object of this part 1 is to provide a set of requirements and tests which are considered to be generally applicable to most types of luminaires and which can be called up as required by the detail specifications of IEC 60598-2. This part 1 is thus not to be regarded as a specification in itself for any type of luminaire, and its provisions apply only to particular types of luminaires to the extent determined by the appropriate section of part 2. The sections of part 2, in making reference to any of the sections of part 1, specify the extent to which that section is applicable and the order in which the tests are to be performed; they also include additional requirements as necessary. The order in which the sections of part 1 are numbered has no particular significance as the order in which their provisions apply is determined for each type of luminaire or group of luminaires by the appropriate section of part 2. All sections of part 2 are self-contained and therefore do not contain references to other sections of part 2. Where the requirements of any of the sections of part 1 are referred to in the sections of part 2 by the phrase "The requirements of section ... of IEC 60598-1 apply", this phrase is to be interpreted as meaning that all the requirements of that section of part 1 apply except those which are clearly inapplicable to the particular type of luminaire covered by that section of part 2. For explosion proof luminaires, as covered by IEC 60079, the requirements of IEC 60598 (selecting the appropriate section(s) of Part 2) are applied in addition to the requirements of IEC 60079. In the event of any conflict between IEC 60598 and IEC 60079, the requirements of IEC 60079 are to take priority. In accordance with IEC guidelines, new IEC standards are divided into those covering either safety or performance. In the lamp safety standards, “information for luminaire design” is given for the safe operation of lamps; this should be regarded as normative when testing luminaires to this standard. Attention is drawn to lamp performance standards which contain “information for luminaire design”; this should be followed for proper lamp operation; however, this standard does not require the testing of lamps performance as part of the type test approval for luminaires. Improvements in safety to take account of the state of the art technology are incorporated in the standards with revisions and amendments on an ongoing basis. Regional standardisation bodies may include statements in their derived standards to cover products which have complied with the previous document as shown by the manufacturer or standardization body. The statements may require that for such products the previous standard may continue to apply to production until a defined date after which the new standard shall apply.
First published as AS/NZS 60598.1:1998.
Second edition 2001.
Third edition 2003.
AS/NZS 4695.2.2:1996 | Fire hazard testing of electrotechnical products Test methods - Needle-flame test |
AS/NZS 60598.2.1:1998 | Luminaires Particular requirements - Fixed general purpose luminaires (Reconfirmed 2013) |
AS/NZS 60695.2.10:2001 | Glowing/hot wire based test methods Glow-wire apparatus and common test procedure |
AS/NZS 61347.2.8:2003 | Lamp controlgear Particular requirements for ballasts for fluorescent lamps (IEC 61347-2-8:2000, MOD) (Reconfirmed 2019) |
AS/NZS 3000:2000 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 61347.1:2002 | Lamp controlgear General and safety requirements (IEC 61347-1:2000, MOD) |
AS/NZS 4695.707:1996 | Fire hazard testing of electrotechnical products Methods of test for the determination of the flammability of solid electrical insulating materials when exposed to an igniting source |
AS/NZS 60598.2.8:2002 | Luminaires Particular requirements - Handlamps (IEC 60598-2-8:2001, MOD) |
AS/NZS 60598.2.6:1998 | Luminaires Particular requirements - Luminaires with built-in transformers or convertors for filament lamps (Reconfirmed 2013) |
AS/NZS 60598.2.23:2002 | Luminaires Particular requirements - Extra low voltage lighting systems for filament lamps (IEC 60598.2.23:1996, MOD) (Reconfirmed 2016) |
AS/NZS 60598.2.4:1998 | Luminaires Particular requirements - Portable general purpose luminaires |
AS/NZS 3131:2001 | Approval and test specification - Plugs and socket-outlets for stationary appliances |
AS/NZS 60598.2.2:2001 | Luminaires Particular requirements - Recessed luminaires (IEC 60598-2-2:1996, MOD) |
AS/NZS 4695.112:1996 | Fire hazard testing of electrotechnical products Method for determining the comparative and the proof tracking indices of solid insulating materials under moist conditions |
AS/NZS 60598.2.19:2001 | Luminaires Particular requirements - Air handling luminaires (Safety requirements) (IEC 60598.2.19:1981, MOD) (Reconfirmed 2013) (Reconfirmed 2024) |
AS/NZS 61535.1(INT):2001 | Installation couplers General requirements |
AS/NZS 61347.2.6:2002 | Lamp controlgear Particular requirements for d.c. supplied electronic ballasts for aircraft lighting |
AS 1104-1978 | Informative symbols for use on electrical and electronic equipment |
AS/NZS 61347.2.11:2003 | Lamp controlgear Particular requirements for miscellaneous electronic circuits used with luminaires (IEC 61347-2-11:2001 MOD) (Reconfirmed 2016) |
AS/NZS 60598.2.10:1998 | Luminaires Particular requirements - Portable child-appealing luminaires (Reconfirmed 2013) |
AS/NZS 3108:1994 | Approval and test specification - Particular requirements for isolating transformers and safety isolating transformers |
AS/NZS 60598.2.20:2002 | Luminaires Particular requirements - Lighting chains (IEC 60598-2-20:1996, MOD) |
AS/NZS 61347.2.1:2002 | Lamp controlgear Particular requirements for starting devices (other than glow starters) |
AS/NZS 60598.2.25:2001 | Luminaires Particular requirements - Luminaires for use in clinical areas of hospitals and health care buildings (IEC 60598.2.25:1994, MOD) (Reconfirmed 2013) (Reconfirmed 2024) |
AS 1939-1990 | Degrees of protection provided by enclosures for electrical equipment (IP Code) |
AS/NZS 61347.2.4:2002 | Lamp controlgear Particular requirements for d.c. supplied electronic ballasts for general lighting |
AS/NZS 60598.2.18:1998 | Luminaires Particular requirements - Luminaires for swimming pools and similar applications (Reconfirmed 2013) |
AS/NZS 3100:2002 | Approval and test specification - General requirements for electrical equipment |
AS/NZS 60598.2.5:2002 | Luminaires Particular requirements - Floodlights(IEC 60598.2.5:1998, MOD) |
AS/NZS 3109.1:1996 | |
AS/NZS 60155:2000 | Glow-starters for fluorescent lamps |
AS/NZS 3112:2000 | Approval and test specification - Plugs and socket-outlets |
AS/NZS 61347.2.5:2002 | Lamp controlgear Particular requirements for d.c. supplied electronic ballasts for public transport |
AS/NZS 60598.2.12:2013 | Luminaires Particular requirements - Mains socket-outlet mounted nightlights |
AS/NZS 1158.6:2010 | Lighting for roads and public spaces Luminaires |
AS/NZS IEC 61347.2.13:2013 | Lamp controlgear Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules (IEC 61347-2-13, Ed.1.0 (2006) MOD) |
AS/NZS 3140:2007 | Approval and test specification - Edison-type screw lampholders |
AS 2293.3-2005 | Emergency escape lighting and exit signs for buildings Emergency escape luminaires and exit signs |
AS/NZS 1680.1:2006 | Interior and workplace lighting General principles and recommendations |
AS/NZS 3004.2:2008 | Electrical installations - Marinas and recreational boats Recreational boats installations |
AS/NZS 60432.1:2007 | Incandescent lamps - Safety specifications Tungsten filament lamps for domestic and similar general lighting purposes (Reconfirmed 2018) |
AS/NZS 60238:2007 | Edison screw lampholders (IEC 60238, Ed.8.0 (2004) MOD) |
AS/NZS 60598.2.22:2005 | Luminaires Particular requirements - Luminaires for emergency lighting (IEC 60598-2 22, Ed. 3.1(2002) MOD) |
AS/NZS CISPR 15:2011 | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment (CISPR 15, Ed.7.2 (2009) MOD) |
AS/NZS CISPR 15:2006 | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
AS/NZS 60598.2.4:2005 | Luminaires Particular requirements - Portable general purpose luminaires (IEC 60598-2-4, Ed. 2.0 (1997) MOD) (Reconfirmed 2016) |
AS/NZS 5110:2011 | Recessed luminaire barriers (Reconfirmed 2020) |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 4703:2007 | Electrical wiring in furniture (Reconfirmed 2018) |
AS/NZS 3117:2007 | Approval and test specification - Bayonet lampholders |
AS/NZS 60927:2005 | Auxiliaries for lamps - Starting devices (other than glow starters) - Performance requirements (IEC 60927, Ed.2.2 (2004) MOD) |
AS/NZS 60079.15:2011 | Explosive atmospheres Equipment protection by type of protection 'n' |
AS/NZS 1158.6:2004 | Lighting for roads and public spaces Luminaires |
AS/NZS 3350.1:2002 | Safety of household and similar electrical appliances General requirements (IEC 60335-1:1991, MOD) |
AS/NZS 4782.1:2004 | Double-capped fluorescent lamps - Performance specifications General (IEC 60081:2000, MOD) (Reconfirmed 2016) |
AS/NZS 61184:2007 | Bayonet lampholders (IEC 61184, Ed. 2.0 (1997) MOD) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.