Explosive atmospheres Protection of equipment and transmission systems using optical radiation
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
30-10-2017
English
26-04-2007
Explains the potential ignition hazard from equipment using optical radiation intended for use in explosive gas atmospheres. It also covers equipment, which itself is located outside but its emitted optical radiation enters such atmospheres. It describes precautions and requirements to be taken when using optical radiation transmitting equipment in explosive gas atmospheres.
Committee |
EL-014
|
DocumentType |
Standard
|
ISBN |
0 7337 8168 3
|
Pages |
27
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
Standards | Relationship |
IEC 60079-28:2006 | Identical |
First published as AS/NZS 60078.29:2007.
AS/NZS 60079.0:2005 | Electrical apparatus for explosive gas atmospheres General requirements |
AS/NZS 2211.2:2006 | Safety of laser products Safety of optical fibre communication systems (OFCS) |
AS/NZS 60079.25:2004 | Electrical apparatus for explosive gas atmospheres Intrinsically safe systems |
AS/NZS 60079.26 (INT):2005 | Electrical apparatus for explosive gas atmospheres Construction, test and marking of Group II Zone 0 electrical apparatus |
AS/NZS 60079.18:2005 | Electrical apparatus for explosive gas atmospheres Construction, test and marking of type of protection encapsulation m electrical apparatus |
AS/NZS 60079.12:2000 | Electrical apparatus for explosive gas atmospheres Classification of mixtures of gases or vapours with air according to their maximum experimental safe gaps and minimum igniting currents |
AS/NZS 60079.15:2006 | Electrical apparatus for explosive gas atmospheres Construction, test and marking of type of protection, n electrical apparatus |
AS IEC 61511.1-2004 | Functional safety - Safety instrumented systems for the process industry sector - Framework, definitions, systems, hardware and software requirements |
AS/NZS 60079.11:2006 | Explosive atmospheres Equipment protection by intrinsic safety 'i' |
AS/NZS 60079.7:2006 | Explosive atmospheres Equipment protection by increased safety 'e' |
AS/NZS 60079.1.1:2002 | Electrical apparatus for explosive gas atmospheres Flameproof enclosures 'd' - Method of test for ascertainment of maximum experimental safe gap |
AS IEC 61511.3-2004 | Functional safety - Safety instrumented systems for the process industry sector - Guidance for the determination of the required safety integrity levels (Reconfirmed 2015) |
AS/NZS 60079.2:2002 | Electrical apparatus for explosive gas atmospheres Pressurized enclosures 'p' |
AS/NZS 60079.10:2004 | Electrical apparatus for explosive gas atmospheres Classification of hazardous areas (IEC 60079-10:2002 MOD) |
AS/NZS 60079.1:2005 | Electrical apparatus for explosive gas atmospheres Flameproof enclosures 'd' |
AS/NZS 60079.6:2000 | Electrical apparatus for explosive gas atmospheres Oil-immersion 'o' |
AS/NZS 60079.27(INT):2006 | Electrical apparatus for explosive gas atmospheres Fieldbus intrinsically safe concept (FISCO) and fieldbus non-incendive concept (FNICO) |
AS/NZS 60079.5:2000 | Electrical apparatus for explosive gas atmospheres Powder filling 'q' |
AS/NZS 60079.20:2000 | Electrical apparatus for explosive gas atmospheres Data for flammable gases and vapours, relating to the use of electrical apparatus |
AS IEC 61511.2-2004 | Functional safety - Safety instrumented systems for the process industry sector - Guidelines for the application of AS IEC 61511-1 |
AS/NZS 60079.4:2000 | Electrical apparatus for explosive gas atmospheres Method of test for ignition temperature |
AS 4647-2011 | Diaphragm gas meters |
AS/NZS 60079.17:2009 | Explosive atmospheres Electrical installations inspection and maintenance (IEC 60079-17, Ed.4.0 (2007) MOD) |
AS/NZS 60335.2.11:2009 | Household and similar electrical appliances - Safety Particular requirements for tumble dryers (IEC 60335-2-11 Ed 7.1, MOD) |
AS/NZS 60079.0:2008 | Explosive atmospheres Equipment - General requirements |
AS/NZS 4871.1:2010 | Electrical equipment for mines and quarries General requirements |
AS/NZS 60079.33:2012 | Explosive atmospheres Equipment protection by special protection 's' (Reconfirmed 2024) |
AS/NZS 3004.2:2008 | Electrical installations - Marinas and recreational boats Recreational boats installations |
AS/NZS 60079.0:2012 | Explosive atmospheres Equipment - General requirements |
HB 239:2011 | Guidance on the repair and overhaul of electrical equipment for explosive atmospheres |
AS/NZS 5026:2012 | The storage and handling of Class 4 dangerous goods (Reconfirmed 2024) |
HB 13-2007 | Electrical equipment for hazardous areas |
AS ISO 21789:2014 | Gas turbine applications - Safety |
AS/NZS 4871.1:2012 | Electrical equipment for mines and quarries General requirements |
AS/NZS 4871.3:2010 | Electrical equipment for mines and quarries Substations |
AS/NZS 60079.14:2009 | Explosive atmospheres Electrical installations design, selection and erection (IEC 60079-14, Ed. 4.0 (2007) MOD) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.