AS/NZS 4898:1997
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Approval and test specification - Circuit-breakers for overcurrent protection for household and similar installations
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
04-06-2024
English
05-06-1997
Specifies essential safety and associated requirements, for approval and test purposes, for air-break circuit-breakers for operation at 50 Hz or 60 Hz, having a rated voltage not exceeding 440 V (between phases), a rated current not exceeding 125 A and a rated short-circuit capacity not exceeding 25 000 A. Annex ZZ lists variations for Australian and New Zealand conditions. This Standard is based on, but not equivalent to, and reproduced from, IEC 898:1995.
Committee |
EL-004
|
DocumentType |
Standard
|
ISBN |
0 7337 1182 0
|
Pages |
96
|
ProductNote |
To run concurrently with AS 3111-1994 for 10 years
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This standard applies to a.c. air-break circuit-breakers for operation at 50 Hz or 60 Hz, having a rated voltage not exceeding 440 V (between phases), a rated current not exceeding 125 A and a rated short-circuit capacity not exceeding 25 000 A. As far as possible, it is in line with the requirements contained in IEC 947-2.These circuit-breakers are intended for the protection against overcurrents of wiring installations of buildings and similar applications; they are designed for use by uninstructed people and for not being maintained.This standard also applies to circuit-breakers having more than one rated current, provided that the means for changing from one discrete rating to another is not accessible in normal service and that the rating cannot be changed without the use of a tool.This standard does not apply to:- circuit-breakers intended to protect motors,- circuit-breakers, the current setting of which is adjustable by means accessible to the user.For circuit-breakers having a degree of protection higher than IP20 according to IEC 529, for use in locations where arduous environmental conditions prevail (e.g. excessive humidity, heat or cold or deposition of dust) and in hazardous locations (e.g. where explosions are liable to occur) special constructions may be required.Requirements for circuit-breakers which incorporate residual current tripping devices are to be found in IEC 1009-1, IEC 1009-2-1, and IEC 1009-2-2.A guide for coordination of circuit-breakers with fuses is given in annex D.NOTES1 Circuit-breakers within the scope of this standard are considered as suitable for isolation (see 8.1.3).Special installation precautions (e.g. use of adequate lightning arresters) may be necessary when excessive overvoltages are likely to occur on the supply side (e.g. in the case of supply through overhead lines).2 Circuit-breakers within the scope of this standard may also be used for protection against electric shock, in case of a fault, depending on their tripping characteristics and on the characteristics of the installation.3 The criterion of application for such purposes is dealt with by installation rules.
First published as Joint Standard AS/NZS 4898:1997.
AS 1852.441-1985 | International electrotechnical vocabulary - Switchgear, controlgear and fuses |
AS 3147-1992 | Approval and test specification - Electric cables - Thermoplastic insulated - For working voltages up to and including 0.6/1 kV |
AS 3000-1986 | Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules) |
AS 2005.10-1988 | Low voltage fuses - Fuses with enclosed fuse-links General requirements |
AS 1104-1978 | Informative symbols for use on electrical and electronic equipment |
AS 1939-1990 | Degrees of protection provided by enclosures for electrical equipment (IP Code) |
AS 3100-1990 | Approval and test specification - General requirements for electrical equipment |
AS 2926-1987 | Standard voltages - Alternating (50 Hz) and direct |
AS/NZS 3105:2002 | Approval and test specification - Electrical portable outlet devices |
AS/NZS 61558.2.6:2001 | Safety of power transformers, power supply units and similar Particular requirements for safety isolating transformers for general use (IEC 61558-2-6:1997, MOD) |
AS/NZS 60269.3.1:2002 | Low-voltage fuses Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) - Sections I to IV: Examples of types of standardized fuses |
AS/NZS 3190:2002 | Approval and test specification - Residual current devices (current-operated earth-leakage devices) |
AS/NZS 3439.3:2002 | Low-voltage switchgear and controlgear assemblies Particular requirements for low voltage switchgear and controlgear assemblies intended to be installed in places where unskilled persons have access for their use - Distribution boards (IEC 60439-3:1990 MOD) |
AS/NZS 3947.2:2002 | Low-voltage switchgear and controlgear Circuit-breakers |
AS 3947.2-1997 | Low-voltage switchgear and controlgear Circuit-breakers |
AS/NZS 3003:2003 | Electrical installations - Patient treatment areas of hospitals and medical, dental practices and dialyzing locations |
AS/NZS 61009.1:1999 | Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) General rules |
AS/NZS 3012:2003 | Electrical installations - Construction and demolition sites |
AS/NZS 61558.1:2000 | |
AS/NZS 3000:2000 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 3017:2001 | Electrical installations - Testing and inspection guidelines |
HB 301-2001 | Electrical installations - Designing to the Wiring rules |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.