AS/NZS 3896:1998
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Waters - Examination for legionellae including Legionella pneumophila
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
29-05-2024
05-03-1998
Specifies a method for detecting and estimating the number of Legionella pneumophila and some other legionellae in water. In this revision the biocide reduction step has been deleted as the dilution factors within this method, i.e. 0.1 mL onto agar plates, are sufficient to overcome any residual antimicrobial activity within the sample submitted for testing.
Committee |
FT-020
|
DocumentType |
Standard
|
ISBN |
0 7337 1733 0
|
Pages |
12
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard sets out a method for detecting and estimating the number of Legionella pneumophila and a range of other legionellae in water.NOTES:A flow chart of the procedure is shown in Appendix A. This Method will identify the species L. pneumophila but not all other legionellae (see Preface). Conditions that favour the isolation of L. pneumophila do not necessarily apply to some other legionellae. A step is included (see Note in Clause 8.2.4) to enhance the sensitivity of the method for such species. This Standard describes the testing of a sample of water as delivered to the laboratory and provides some information regarding sample size and delivery conditions. In samples submitted for testing, the dilution factors within this method i.e. 0.1 mL onto agar plates are sufficient to overcome any residual antimicrobial activity within the sample.
First published in Australia as AS 3896-1991.
Jointly revised and designated AS/NZS 3896:1998.
AS 2031.2-1987 | Selection of containers and preservation of water samples for chemical and microbiological analysis - Microbiological |
AS/NZS 2243.3:2002 | Safety in laboratories Microbiological aspects and containment facilities |
AS 2243.3-1985 | Safety in laboratories - Microbiology |
AS/NZS 3666.3(INT):1998 | Air-handling and water systems of buildings - Microbial control - Performance-based maintenance of cooling water systems |
AS 5059-2006 | Power station cooling tower water systems - Management of legionnaires' disease health risk (Reconfirmed 2016) |
SAA/SNZ HB32:1995 | Control of microbial growth in air-handling and water systems in buildings (Reconfirmed 2016) |
AS/NZS 3666.3:2000 | Air-handling and water systems of buildings - Microbial control Performance-based maintenance of cooling water systems |