Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS/NZS 3808:2000

Current

Current

The latest, up-to-date edition.

Insulating and sheathing materials for electric cables (Reconfirmed 2017)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

12-05-2000

Preview
$119.17
Including GST where applicable

Specifies the tests and criteria, referenced in particular Standards, for elastomeric, PVC, reduced fire hazard and polyolefin insulating and sheathing materials used in the construction of electric cables and flexible cords. It does not cover tests that can only be conducted on completed cables.

Committee
EL-003
DocumentType
Standard
ISBN
0 7337 3373 5
Pages
22
ProductNote
Reconfirmed 20/01/2017.This standard has been reconfirmed in Australia in 2017 and remains current in New Zealand. Reconfirmation Notice 20/01/2017
PublisherName
Standards Australia
Status
Current
Supersedes
UnderRevision

This Standard specifies the tests and criteria for elastomeric, PVC, reduced fire hazard and polyolefin insulating and sheathing materials used in the construction of electric cables and flexible cords and referenced in Australian and Australian/New Zealand Standards. It applies to electric cables and cords designed for working voltages up to and including 76/132(145) kV. This Standard does not cover tests that can only be conducted on completed cables, e.g. partial discharge, tan d, impulse, high voltage, shrinkage and adhesion tests.The requirements of this Standard only apply when referenced in other relevant Standards. This Standard does not supersede requirements in existing Standards.NOTE: Insulating and sheathing materials in other relevant Standards are listed in Table A1 of Appendix A.

Originated as AS/NZS 3808:1998 Second edition 2000 Reissued incorporating Amendment No. 1 (July 2002).

Reissued incorporating Amendment No. 2 (August 2004).

AS/NZS 1802:1995 Electric cables - Reeling and trailing - For underground coal mining purposes
AS 3599.1-1988 Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11(12) kV and 12.7/22(24) kV Metallic screened
AS/NZS 2373.1:1995 Electric cables for control and protection circuits Multicore control cables
AS/NZS 3560.1:2000 Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1(1.2) kV Aluminium conductors (Reconfirmed 2021)
AS 1049-1996 Telecommunication cables - Insulation, sheath and jacket
AS 1429.1-1993 Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV
AS/NZS 3008.1.2:1998 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand installation conditions
AS 4026-1992 Electric cables - For underground residential distribution systems
AS 2276.1-1992 Cables for traffic signal installations - Multicore power cables
AS/NZS 2373.2:1995 Electric cables for control and protection circuits - Twisted pair control cables
AS 1026-1992 Electric cables - Impregnated paper insulated - Working voltages up to and including 33 kV
AS 2276.3-1992 Cables for traffic signal installations - Loop cable for vehicle detectors
AS 2802-1992 Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining)
AS 3158-1994 Approval and test specification - Electric cables - Glass fibre insulated for working voltages up to and including 0.6/1 kV
AS/NZS 3166:1993 Approval and test specification - Cables for high voltage luminous discharge tube installations (Reconfirmed 2017)
AS/NZS 1972:1996 Electric cables - Underground coal mines - Other than reeling and trailing
AS/NZS 3599.2:1999 Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11(12) kV and 12.7/22(24) kV Non-metallic screened
AS 1747-1993 Reeling, trailing and feeder cables used for mining - Repair and testing
AS/NZS 5000.1:1999 Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 kV
AS/NZS 1429.2:1998 Electric cables - Polymeric insulated - For working voltages above 19/33 (36) kV up to and including 76/132 (145) kV
AS 3675-1993 Conductors - Covered overhead - For working voltages 6.35/11 kV up to and including 19/33 kV
AS/NZS 3155:1995 Approval and test specification - Electric cables - Neutral screened - For working voltages up to and including 0.6/1 kV
AS/NZS 4193.2:1994 Electric cables for use in ships Insulating materials for shipboard power cables
AS 3178-1991 Approval and test specification - Electric cables - Silicone rubber insulated - For working voltages up to and including 0.6/1 kV
AS 1979-1993 Electric cables - Lifts - Flexible travelling
AS/NZS 3187:1995 Approval and test specification - Mineral-insulated metal-sheathed cables
AS 1178-1986 Concentric wire neutral cables - XLPE insulated - For electricity supply at working voltages of 0.6/1 kV
AS/NZS 5000.2:1999 Electric cables - Polymeric insulated For working voltages up to and including 450/750 V
AS/NZS 2276.2:1998 Cables for traffic signal installations Feeder cable for vehicle detectors
AS/NZS 3008.1.1:1998 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
AS/NZS 4193.3:1994 Electric cables for use in ships Sheathing materials for shipboard power, control and telecommunication cables
AS/NZS 1995:1995 Welding cables
AS/NZS 3191:1996 Approval and test specification - Electric flexible cords

AS/NZS 3599.2:1999 Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11(12) kV and 12.7/22(24) kV Non-metallic screened
AS/NZS 2276.3:2002 Cables for traffic signal installations Loop cable for vehicle detectors (Reconfirmed 2017)
AS/NZS 5000.1:2005 Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017)
AS/NZS 5000.3:2003 Electric cables - Polymeric insulated Multicore control cables (Reconfirmed 2017)
AS/NZS 2373:2003 Electric cables - Twisted pair for control and protection circuits (Reconfirmed 2017)
AS/NZS 5000.2:2006 Electric cables - Polymeric insulated For working voltages up to and including 450/750 V (Reconfirmed 2017)
AS/NZS 1429.1:2006 Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV
AS/NZS 1995:2003 Welding cables (Reconfirmed 2017)
AS/NZS 3191:2008 Electric flexible cords (Reconfirmed 2019)
AS/NZS 2802:2000 Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining) (Reconfirmed 2020)
AS/NZS 1972:2006 Electric cables - Underground coal mines - Other than reeling and trailing (Reconfirmed 2020)
AS/NZS 1802:2003 Electric cables - Reeling and trailing - For underground coal mining purposes
AS/NZS 4026:2008 Electric cables - For underground residential distribution systems
AS/NZS 4961:2003 Electric cables - Polymeric insulated - For distribution and service applications (Reconfirmed 2017)
AS/NZS 3191:2003 Electric flexible cords
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS/NZS 1802:2018 Electric cables - Reeling and trailing - For underground coal mining
AS/NZS 1026:2004 Electric cables - Impregnated paper insulated - For working voltages up to and including 19/33 (36) kV
DR 00391 Conductors - Covered overhead - For working voltages 6.35/11(12)kV up to and including 19/33(36)kV
AS/NZS 3013:2005 Electrical installations - Classification of the fire and mechanical performance of wiring system elements (Reconfirmed 2020)
AS/NZS 1972:2002 Electric cables - Underground coal mines - Other than reeling and trailing
AS/NZS 2276.2:1998 Cables for traffic signal installations Feeder cable for vehicle detectors
AS/NZS 3675:2002 Conductors - Covered overhead - For working voltages 6.35/11 (12) kV up to and including 19/33 (36) kV (Reconfirmed 2017)
AS/NZS 3560.2:2003 Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1 (1.2) kV Copper conductors
AS/NZS 1429.2:2009 Electric cables - Polymeric insulated For working voltages above 19/33 (36) kV up to and including 87/150 (170) kV (Reconfirmed 2020)
AS/NZS 5000.1:2003 Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV
AS/NZS 1429.1:2000 Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS/NZS 3599.1:2003 Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11 (12) kV and 12.7/22 (24) kV Metallic screened (Reconfirmed 2021)
AS/NZS 2276.1:2004 Cables for traffic signal installations Multicore power cables (Reconfirmed 2017)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.