AS/NZS 3808:2000
Current
The latest, up-to-date edition.
Insulating and sheathing materials for electric cables (Reconfirmed 2017)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
12-05-2000
Specifies the tests and criteria, referenced in particular Standards, for elastomeric, PVC, reduced fire hazard and polyolefin insulating and sheathing materials used in the construction of electric cables and flexible cords. It does not cover tests that can only be conducted on completed cables.
Committee |
EL-003
|
DocumentType |
Standard
|
ISBN |
0 7337 3373 5
|
Pages |
22
|
ProductNote |
Reconfirmed 20/01/2017.This standard has been reconfirmed in Australia in 2017 and remains current in New Zealand. Reconfirmation Notice 20/01/2017
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes | |
UnderRevision |
This Standard specifies the tests and criteria for elastomeric, PVC, reduced fire hazard and polyolefin insulating and sheathing materials used in the construction of electric cables and flexible cords and referenced in Australian and Australian/New Zealand Standards. It applies to electric cables and cords designed for working voltages up to and including 76/132(145) kV. This Standard does not cover tests that can only be conducted on completed cables, e.g. partial discharge, tan d, impulse, high voltage, shrinkage and adhesion tests.The requirements of this Standard only apply when referenced in other relevant Standards. This Standard does not supersede requirements in existing Standards.NOTE: Insulating and sheathing materials in other relevant Standards are listed in Table A1 of Appendix A.
Originated as AS/NZS 3808:1998 Second edition 2000 Reissued incorporating Amendment No. 1 (July 2002).
Reissued incorporating Amendment No. 2 (August 2004).
AS/NZS 1802:1995 | Electric cables - Reeling and trailing - For underground coal mining purposes |
AS 3599.1-1988 | Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11(12) kV and 12.7/22(24) kV Metallic screened |
AS/NZS 2373.1:1995 | Electric cables for control and protection circuits Multicore control cables |
AS/NZS 3560.1:2000 | Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1(1.2) kV Aluminium conductors (Reconfirmed 2021) |
AS 1049-1996 | Telecommunication cables - Insulation, sheath and jacket |
AS 1429.1-1993 | Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV |
AS/NZS 3008.1.2:1998 | Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand installation conditions |
AS 4026-1992 | Electric cables - For underground residential distribution systems |
AS 2276.1-1992 | Cables for traffic signal installations - Multicore power cables |
AS/NZS 2373.2:1995 | Electric cables for control and protection circuits - Twisted pair control cables |
AS 1026-1992 | Electric cables - Impregnated paper insulated - Working voltages up to and including 33 kV |
AS 2276.3-1992 | Cables for traffic signal installations - Loop cable for vehicle detectors |
AS 2802-1992 | Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining) |
AS 3158-1994 | Approval and test specification - Electric cables - Glass fibre insulated for working voltages up to and including 0.6/1 kV |
AS/NZS 3166:1993 | Approval and test specification - Cables for high voltage luminous discharge tube installations (Reconfirmed 2017) |
AS/NZS 1972:1996 | Electric cables - Underground coal mines - Other than reeling and trailing |
AS/NZS 3599.2:1999 | Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11(12) kV and 12.7/22(24) kV Non-metallic screened |
AS 1747-1993 | Reeling, trailing and feeder cables used for mining - Repair and testing |
AS/NZS 5000.1:1999 | Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 kV |
AS/NZS 1429.2:1998 | Electric cables - Polymeric insulated - For working voltages above 19/33 (36) kV up to and including 76/132 (145) kV |
AS 3675-1993 | Conductors - Covered overhead - For working voltages 6.35/11 kV up to and including 19/33 kV |
AS/NZS 3155:1995 | Approval and test specification - Electric cables - Neutral screened - For working voltages up to and including 0.6/1 kV |
AS/NZS 4193.2:1994 | Electric cables for use in ships Insulating materials for shipboard power cables |
AS 3178-1991 | Approval and test specification - Electric cables - Silicone rubber insulated - For working voltages up to and including 0.6/1 kV |
AS 1979-1993 | Electric cables - Lifts - Flexible travelling |
AS/NZS 3187:1995 | Approval and test specification - Mineral-insulated metal-sheathed cables |
AS 1178-1986 | Concentric wire neutral cables - XLPE insulated - For electricity supply at working voltages of 0.6/1 kV |
AS/NZS 5000.2:1999 | Electric cables - Polymeric insulated For working voltages up to and including 450/750 V |
AS/NZS 2276.2:1998 | Cables for traffic signal installations Feeder cable for vehicle detectors |
AS/NZS 3008.1.1:1998 | Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions |
AS/NZS 4193.3:1994 | Electric cables for use in ships Sheathing materials for shipboard power, control and telecommunication cables |
AS/NZS 1995:1995 | Welding cables |
AS/NZS 3191:1996 | Approval and test specification - Electric flexible cords |
AS/NZS 3599.2:1999 | Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11(12) kV and 12.7/22(24) kV Non-metallic screened |
AS/NZS 2276.3:2002 | Cables for traffic signal installations Loop cable for vehicle detectors (Reconfirmed 2017) |
AS/NZS 5000.1:2005 | Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017) |
AS/NZS 5000.3:2003 | Electric cables - Polymeric insulated Multicore control cables (Reconfirmed 2017) |
AS/NZS 2373:2003 | Electric cables - Twisted pair for control and protection circuits (Reconfirmed 2017) |
AS/NZS 5000.2:2006 | Electric cables - Polymeric insulated For working voltages up to and including 450/750 V (Reconfirmed 2017) |
AS/NZS 1429.1:2006 | Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV |
AS/NZS 1995:2003 | Welding cables (Reconfirmed 2017) |
AS/NZS 3191:2008 | Electric flexible cords (Reconfirmed 2019) |
AS/NZS 2802:2000 | Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining) (Reconfirmed 2020) |
AS/NZS 1972:2006 | Electric cables - Underground coal mines - Other than reeling and trailing (Reconfirmed 2020) |
AS/NZS 1802:2003 | Electric cables - Reeling and trailing - For underground coal mining purposes |
AS/NZS 4026:2008 | Electric cables - For underground residential distribution systems |
AS/NZS 4961:2003 | Electric cables - Polymeric insulated - For distribution and service applications (Reconfirmed 2017) |
AS/NZS 3191:2003 | Electric flexible cords |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 1802:2018 | Electric cables - Reeling and trailing - For underground coal mining |
AS/NZS 1026:2004 | Electric cables - Impregnated paper insulated - For working voltages up to and including 19/33 (36) kV |
DR 00391 | Conductors - Covered overhead - For working voltages 6.35/11(12)kV up to and including 19/33(36)kV |
AS/NZS 3013:2005 | Electrical installations - Classification of the fire and mechanical performance of wiring system elements (Reconfirmed 2020) |
AS/NZS 1972:2002 | Electric cables - Underground coal mines - Other than reeling and trailing |
AS/NZS 2276.2:1998 | Cables for traffic signal installations Feeder cable for vehicle detectors |
AS/NZS 3675:2002 | Conductors - Covered overhead - For working voltages 6.35/11 (12) kV up to and including 19/33 (36) kV (Reconfirmed 2017) |
AS/NZS 3560.2:2003 | Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1 (1.2) kV Copper conductors |
AS/NZS 1429.2:2009 | Electric cables - Polymeric insulated For working voltages above 19/33 (36) kV up to and including 87/150 (170) kV (Reconfirmed 2020) |
AS/NZS 5000.1:2003 | Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV |
AS/NZS 1429.1:2000 | Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV |
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 3599.1:2003 | Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11 (12) kV and 12.7/22 (24) kV Metallic screened (Reconfirmed 2021) |
AS/NZS 2276.1:2004 | Cables for traffic signal installations Multicore power cables (Reconfirmed 2017) |