AS/NZS 3580.9.7:2009
Current
The latest, up-to-date edition.
Methods for sampling and analysis of ambient air Determination of suspended particulate matter - Dichotomous sampler (PM (Reconfirmed 2020)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
18-02-2009
The objective of this Standard is to provide regulatory and testing bodies with a standard method for determining suspended particulate matter with equivalent aerodynamic diameters of less than 10 ?m and 2.5 ?m, utilizing a dichotomous sampler and size selective inlet. The procedure described in this Standard involves batch sampling and the gravimetric determination of coarse PM, PM2.5 and PM10.
Committee |
EV-007
|
DocumentType |
Standard
|
ISBN |
0 7337 9028 3
|
Pages |
13
|
ProductNote |
Reconfirmed 11/09/2020.
This standard has been reconfirmed in Australia in 2020 and remains current in New Zealand. Reconfirmation Notice 11/09/2020 |
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This Standard sets out a gravimetric procedure for the concurrent determination of the PM10 and PM2.5 fractions of suspended particulate matter in ambient air collected in a dichotomous sampler. The method provides a measure of the mean concentration of PM10 over the sampling period of the two size fractions, viz. the fine fraction (less than approximately 2.5 µm) and the coarse fraction (2.5 µm to 10 µm). A procedure for assessing the performance of dichotomous samplers so that they comply with the sampling requirements of this method, is described in Appendix A. NOTE: Sampling is normally of 24 h duration to average out diurnal variations. Provided that the mass of the filter is determined under carefully controlled laboratory conditions, mean concentrations of 5 µg/m3 (1.67 L/min sample flow rate) or 1 µg/m3 (15 L/min sample flow rate) and greater may be determined, based on a 24 h sampling period.
Originated as AS 3580.9.7-1990.
Jointly revised and designated as AS/NZS 3580.9.7:2009.
AS/NZS 3580.1.1:2007 | Methods for sampling and analysis of ambient air Guide to siting air monitoring equipment |
AS/NZS 3760:2003 | In-service safety inspection and testing of electrical equipment |
AS ISO/IEC 17025-2005 | General requirements for the competence of testing and calibration laboratories (Reconfirmed 2016) |
AS 2162.1-1996 | Verification and use of volumetric apparatus General - Volumetric glassware |
AS/NZS 3580.1.1:2016 | Methods for sampling and analysis of ambient air Guide to siting air monitoring equipment |
AS 3580.19:2020 | Methods for sampling and analysis of ambient air Ambient air quality data validation and reporting |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.