Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS/NZS 3008.1.2:2017

Current

Current

The latest, up-to-date edition.

Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

02-02-2017

Preview
$282.33
Including GST where applicable

This Standard sets out a method for cable selection for those types of electrical cables and methods of installation that are in common use at working voltages up to and including 0.6/1kV at 50Hz a.c.

Committee
EL-001
DocumentType
Standard
ISBN
978 1 76035 657 6
Pages
140
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard sets out a method for cable selection for those types of electrical cables and methods of installation that are in common use at working voltages up to and including 0.6/1 kV at 50 Hz a.c.Four criteria are given for cable selection, as follows:(a) Current-carrying capacity.(b) Voltage drop.(c) Short-circuit temperature rise.(d) Economic optimization.This Standard provides sustained current-carrying capacities and voltage drop values for those types of electrical cable and installation practices in common use in New Zealand. A significant amount of explanatory material is also provided on the application of rating factors that arise from the particular installation conditions of a single circuit or groups of circuits. Also, provided in Section 5 is information on cable selection based on short-circuit temperature limits.NOTE: A number of worked examples on cable selection are included in Appendix A.This Standard does not take into account the effects that may occur owing to temperature rise at the terminals of equipment and reference is necessary to AS/NZS 3000 and the individual equipment Standards.NOTE: For ease of reference, an index of the Tables included in this Standard is provided in Appendix B.

Originated in Australia as AS 3008.1-1984.
Second edition 1989.
Jointly revised and redesignated AS/NZS 3008.1.2:1998.
Previous edition 2010.
This edition 2017.

AS/NZS 1125:2001 Conductors in insulated electric cables and flexible cords (Reconfirmed 2017)
AS/NZS 3008.1.1:2017 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
AS/NZS 60702.1:2005 Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V Cables
AS/NZS 3560.2:2003 Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1 (1.2) kV Copper conductors
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS/NZS 5000.2:2006 Electric cables - Polymeric insulated For working voltages up to and including 450/750 V (Reconfirmed 2017)
AS/NZS 3191:2008 Electric flexible cords (Reconfirmed 2019)
AS 1746-1991 Conductors - Bare overhead - Hard-drawn copper
AS/NZS 4026:2008 Electric cables - For underground residential distribution systems
AS 1531-1991 Conductors - Bare overhead - Aluminium and aluminium alloy (Reconfirmed 2016)
AS/NZS 5000.3:2003 Electric cables - Polymeric insulated Multicore control cables (Reconfirmed 2017)
AS/NZS 4961:2003 Electric cables - Polymeric insulated - For distribution and service applications (Reconfirmed 2017)
AS 3158-2004 Electric cables - Glass fibre insulated - For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2016)
AS/NZS 3560.1:2000 Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1(1.2) kV Aluminium conductors (Reconfirmed 2021)
AS/NZS 5000.1:2005 Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017)

AS/NZS 3003:2018 Electrical installations - Patient areas
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) Electrical installations (known as the Australian/New Zealand Wiring Rules)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.