AS 62040.1.1-2003
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Uninterruptible power systems (UPS) General and safety requirements for UPS used in operator access areas
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
28-06-2019
English
01-01-2003
Specifies general and safety requirements for low voltage electronic Uninterruptible Power Systems (UPS) installed in operator accessible areas. This Standard is to be read in conjunction with AS/NZS 60950.1.
Committee |
EL-027
|
DocumentType |
Standard
|
ISBN |
0 7337 5476 7
|
Pages |
38
|
ProductNote |
This standard has been reconfirmed in Australia in 2013 and remains current in New Zealand. Reconfirmation Notice 13-01-2014
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This standard applies to electronic uninterruptible power systems (UPS) with an electrical energy storage device in the d.c. link. It is to be used with IEC 60950-1 which is referred to in this standard as "RD".When any item is referred to by the phrase "The definitions or the provisions of item/RD apply", this phrase is intended to mean that the definitions or provisions in that item of IEC 60950-1 apply, except any which are clearly inapplicable to uninterruptible power systems. National requirements additional to those in IEC 60950-1 apply and are found as notes under relevant clauses of the RD. The primary function of the UPS covered by this standard is to ensure continuity of an alternating power source. The UPS may also serve to improve the quality of the power source by keeping it within specified characteristics. This standard is applicable to UPS which are movable, stationary, fixed or for building-in, for use on low-voltage distribution systems and intended to be installed in any operator accessible area. It specifies requirements to ensure safety for the operator and layman who may come into contact with the equipment and, where specifically stated, for the service person. This standard is intended to ensure the safety of installed UPS, both as a single UPS unit or as a system of interconnected UPS units, subject to installing, operating and maintaining the UPS in the manner prescribed by the manufacturer. This standard does not cover d.c. supplied electronic ballasts (IEC 60924 and IEC 60925), UPS intended to be installed in separated electrical locations and UPS based on rotating machines. The relevant general and safety requirements for UPS installed in restricted access locations are given in IEC 62040-1-2; electromagnetic compatibility (EMC) requirements and definitions are given in IEC 62040-2.
Standards | Relationship |
IEC 62040-1-1:2002 | Identical |
First published as AS 62040.1.1-2003.
AS/NZS 3123:2000 | Approval and test specification - Plugs, socket-outlets and couplers for general industrial application |
AS/NZS 61009.1:1999 | Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) General rules |
AS 1939-1990 | Degrees of protection provided by enclosures for electrical equipment (IP Code) |
AS 62040.2-2001 | Uninterruptible power systems (UPS) - Electromagnetic compatibility (EMC) requirements |
AS/NZS 60950.1:2003 | Information technology equipment - Safety General requirements (IEC 60950-1:2001, MOD) |
AS 62040.1.2-2003 | Uninterruptible power systems (UPS) General and safety requirements for UPS used in restricted access locations |
AS 62040.3-2002 | Uninterruptible power systems (UPS) Method of specifying the performance and test requirements |
AS/NZS 3010:2017 | Electrical installations - Generating sets |
AS/NZS 4777.1:2016 | Grid connection of energy systems via inverters Installation requirements |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 3010:2005 | Electrical installations - Generating sets |
AS 2293.1-2005 | Emergency escape lighting and exit signs for buildings System design, installation and operation |
AS/NZS 5139:2019 | Electrical installations - Safety of battery systems for use with power conversion equipment |
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 3007:2013 | Electrical equipment in mines and quarries - Surface installations and associated processing plant |
AS 62040.1.2-2003 | Uninterruptible power systems (UPS) General and safety requirements for UPS used in restricted access locations |
AS/NZS 2293.1:2018 | Emergency lighting and exit signs for buildings System design, installation and operation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.