Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 3835.3(INT)-1998

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Coordination of power and telecommunications - Earth Potential Rise (EPR) Isolation arrangements for paired cable telemetering/telecontrol services in LV areas and HV sites

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

30-06-2017

Language(s)

English

Published date

01-01-1998

Preview
$169.15
Including GST where applicable

1 - AS 3835.3(Int)-1998 COORDINATION OF POWER AND TELECOMMUNICATIONS - EARTH POTENTIAL RISE (EPR) - ISOLATION ARRANGEMENTS FOR....
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 APPLICATION
6 - 1.3 REFERENCED AND RELATED DOCUMENTS
6 - 1.4 DEFINITIONS - GENERAL
6 - 1.4.1 Aerial cable feed
6 - 1.4.2 Approved device arrangement
6 - 1.4.3 Carrier
6 - 1.4.4 Earth Potential Rise (EPR)
6 - 1.4.5 Exclusive HV pole
6 - 1.4.6 Exclusive LV pole
6 - 1.4.7 Hazard zone
6 - 1.4.8 High voltage (HV)
7 - 1.4.9 HV isolating link
7 - 1.4.10 HV isolation device
7 - 1.4.11 HV site
7 - 1.4.12 Lead-in cable feed
7 - 1.4.13 Low voltage (LV)
7 - 1.4.14 LV switch room
7 - 1.4.15 Normal Joint Use pole
7 - 1.4.16 Power service provider (or service provider)
7 - 1.4.17 Public switched telephone network (PSTN)
7 - 1.4.18 Remote earth
7 - 1.4.19 Remote monitoring system
7 - 1.4.20 Special Joint Use pole
7 - 1.5 DEFINITIONS RELATING TO HV POWER CIRCUITS
7 - 1.6 ABBREVIATIONS RELATING TO COMMUNICATIONS CABLING
8 - SECTION 2 GENERAL REQUIREMENTS
8 - 2.1 THE NEED FOR ISOLATION
8 - 2.1.1 Hazardous voltages
8 - 2.1.2 Arrangements of isolation equipment
8 - 2.1.3 Components of isolation equipment
9 - 2.2 HV ISOLATION DEVICES
9 - 2.2.1 Types of device
9 - 2.2.2 Devices for systems higher than 33 kV
10 - 2.3 ARRANGEMENT
10 - 2.4 TELECOMMUNICATIONS EQUIPMENT IN AN EPR HAZARD ZONE
11 - SECTION 3 TELECOMMUNICATIONS SERVICES IN LV AREAS
11 - 3.1 GENERAL
12 - 3.2 AERIAL SERVICES TO LV POLES
12 - 3.2.1 Aerial service to an LV pole outside any EPR hazard zone
14 - 3.2.2 Aerial service to an LV pole within an EPR hazard zone and a one-unit isolation device
16 - 3.2.3 Aerial service to an LV pole within an EPR hazard zone and a two-unit isolation device
18 - 3.3 UNDERGROUND SERVICES TO LV POLES
18 - 3.3.1 Underground service to an LV pole outside any EPR hazard zone
20 - 3.3.2 Underground service to an LV pole within an EPR hazard zone and a one-unit isolation device
22 - 3.3.3 Underground service to an LV pole within an EPR hazard zone and a two-unit isolation device
25 - 3.4 UNDERGROUND SERVICES INDOORS
25 - 3.4.1 General
26 - 3.4.2 Underground service to LV plant indoors outside any EPR hazard zone
28 - 3.4.3 Underground service to LV plant indoors within an EPR hazard zone and a one-unit isolation device
30 - 3.4.4 Underground service to LV plant indoors within an EPR hazard zone and a two-unit isolation device
32 - SECTION 4 TELECOMMUNICATIONS SERVICES IN HV SITES
32 - 4.1 REMOTE INTERROGATION AND DEMAND MANAGEMENT OF A HV SYSTEM
32 - 4.2 PSTN TELEPHONE SERVICES
33 - 4.3 UNDERGROUND SERVICES TO HV PLANT ON EXCLUSIVE HV POLES
33 - 4.3.1 General
34 - 4.3.2 Underground service to HV plant on an exclusive HV pole and a one-unit isolation device
36 - 4.3.3 Underground service to HV plant on an exclusive HV pole and a two-unit isolation device
38 - 4.4 UNDERGROUND SERVICE TO PLANT ON A HV POLE WITH A RECLOSER AND A DISCONNECTOR
40 - 4.5 UNDERGROUND SERVICES TO HV PLANT INDOORS
41 - SECTION 5 TELECOMMUNICATIONS SERVICES IN PARTICULAR SITUATIONS
41 - 5.1 SERVICES ON CONDUCTIVE POLES
41 - 5.1.1 Normal Joint Use poles
41 - 5.1.2 Other poles
41 - 5.2 SERVICES ON SWER SUPPLY POLES
41 - 5.3 SERVICES ON SINGLE-PHASE HV SPUR SUPPLY POLES
42 - 5.4 UNDERGROUND SERVICES TO PAD-MOUNTED TRANSFORMERS
42 - 5.4.1 General
42 - 5.4.2 Underground service to a pad-mounted transformer with a two-unit isolation device
43 - 5.5 OTHER APPLICATIONS
44 - APPENDIX A - REFERENCED AND RELATED DOCUMENTS
44 - A1 REFERENCED DOCUMENTS
44 - A2 RELATED DOCUMENTS
45 - APPENDIX B - DEFINITIONS FOR HV POWER CIRCUIT CATEGORIES
45 - B1 CATEGORY A CIRCUIT
45 - B2 CATEGORY B CIRCUIT
45 - B3 CATEGORY C CIRCUIT
45 - B4 HIGH RELIABILITY CIRCUIT
47 - APPENDIX C - INSTALLATION OF TELECOMMUNICATIONS EQUIPMENT IN HV SITES
47 - C1 SCOPE
47 - C2 GENERAL
47 - C3 CABLES AND CONDUITS
47 - C4 JOINTS
48 - C5 HV ISOLATING LINKS
48 - C6 HV ISOLATION DEVICES
48 - C7 INSULATING SHROUDS
48 - C8 MOUNTING OF HV ISOLATION EQUIPMENT
51 - C9 DANGER SIGNS
51 - C10 INSULATING MATS
51 - C11 SURGE SUPPRESSION DEVICES
51 - C11.1 General
51 - C11.2 For EPR mitigation
51 - C11.3 For lightning protection
52 - APPENDIX D - THE DANGER SIGN
53 - APPENDIX E - EXAMPLES: POLES AND BUILDINGS LOCATED IN AN EPR ZONE
54 - APPENDIX F - DETERMINATION OF THE EPR HAZARD LEVEL: ISOLATION CHECK LIST
56 - APPENDIX G - INSTALLATION PROCEDURES
56 - G1 THE NEED FOR COOPERATION
56 - G2 PLANNING

Specifies requirements and practices for the isolation of telecommunications services involved in remote metering, remote interrogation and demand management of LV and HV power systems, on poles and in buildings.

CommentClosesDate
05-09-2000
Committee
ET-007
DocumentType
Standard
ISBN
0 7337 2174 5
Pages
51
PublisherName
Standards Australia
Status
Withdrawn

This Interim Standard specifies detailed requirements and practices for the isolation of telecommunications services provided over paired cables and involved in remote metering, remote interrogation and demand management, and the like of LV and HV power systems, on poles and in buildings.NOTE: Services provided by other technologies involving a copper conductor are to be considered by the Committee and might be included after the planned review of this Interim Standard.This Interim Standard specifies pole-mounted arrangements for timber poles and additional arrangements for conductive poles.

First published as AS 3835.3(Int)-1998.

AS/NZS 2053.1:1995 Conduits and fittings for electrical installations General requirements
AS/NZS 1477:1999 PVC pipes and fittings for pressure applications
AS 1939-1990 Degrees of protection provided by enclosures for electrical equipment (IP Code)
AS 1319-1994 Safety signs for the occupational environment (Reconfirmed 2018)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.