Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 3799-1998

Current

Current

The latest, up-to-date edition.

Liquid membrane-forming curing compounds for concrete (Reconfirmed 2018)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

05-11-1998

Preview
$119.17
Including GST where applicable

1 - AS 3799-1998 LIQUID MEMBRANE - FORMING CURING COMPOUNDS FOR CONCRETE
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 APPLICATION
6 - 1.3 REFERENCED DOCUMENTS
7 - 1.4 DEFINITIONS
7 - 1.4.1 Emulsion
7 - 1.4.2 Flammable
7 - 1.4.3 Latex emulsion
7 - 1.4.4 Lot
7 - 1.4.5 Membrane
7 - 1.4.6 Plasticizing material
7 - 1.4.7 Resin
7 - 1.4.8 Solution curing compound
7 - 1.4.9 Vehicle
7 - 1.5 CLASSIFICATION OF CURING COMPOUNDS
7 - 1.5.1 General
8 - 1.5.2 Class
8 - 1.5.3 Type
9 - SECTION 2 CHARACTERISTICS
9 - 2.1 GENERALCHARACTERISTICS
9 - 2.2 SPECIFIC CHARACTERISTICS
10 - SECTION 3 REQUIREMENTS
10 - 3.1 ACCEPTANCE TESTING
10 - 3.1.1 General
10 - 3.1.2 Water retention
10 - 3.1.3 Reflectance
10 - 3.1.4 Drying time
10 - 3.1.5 Viscosity
10 - 3.1.6 Residue on 150 µm sieve
10 - 3.1.7 Shelf life
10 - 3.1.8 Non-volatile content
10 - 3.1.9 Density
10 - 3.2 UNIFORMITY TESTING
11 - 3.3 COMPLIANCE WITH STANDARD
12 - APPENDIX A - SAMPLING PROCEDURE
12 - A1 SCOPE
12 - A2 SAMPLING AT THE POINT OF MANUFACTURE
12 - A3 SAMPLING AT THE POINT OF DELIVERY
12 - A4 PREPARATION OF TEST SAMPLES
12 - A5 IDENTIFICATION, MARKING, STORAGE
13 - A6 REPORT
14 - APPENDIX B - WATER RETENTION EFFICIENCY OF LIQUID MEMBRANE-FORMING CURING COMPOUNDS FOR CONCRETE
14 - B1 SCOPE
14 - B2 PRINCIPLE
14 - B3 MATERIALS
14 - TABLE B1 GRADING REQUIREMENTS
14 - B4 APPARATUS
15 - B5 PREPARATION OF TRIAL SPECIMEN
15 - B6 PREPARATION OF TEST SPECIMENS
15 - B6.1 Number of specimens
15 - B6.2 Mixing mortar
16 - B6.3 Moulding specimens
16 - B7 STORAGE OF SPECIMENS
16 - B8 PREPARATION FOR TESTING
17 - B9 PROCEDURE
17 - B9.1 General
17 - B9.2 Procedure
18 - B10 CALCULATIONS
19 - B11 NON-STANDARD TESTING
19 - B12 RECORDS
20 - B13 REPORT
21 - APPENDIX C - DRYING TIME
21 - C1 SCOPE
21 - C2 PRINCIPLE
21 - C3 PROCEDURE
21 - C4 INTERPRETATION OF RESULTS
21 - C5 RECORDS AND REPORT
22 - APPENDIX D - GENERAL INFORMATION ON THE PROPERTIES OF LIQUID MEMBRANE-FORMING CURING COMPOUNDS
22 - D1 SCOPE
22 - D2 DESCRIPTION
22 - D3 USES
22 - D4 CLASSIFICATION
22 - D5 DESCRIPTION OF CLASSES
22 - D5.1 General
23 - D5.2 Class A - Wax-based compounds
23 - D5.3 Class B - Resin-based compounds
23 - D5.4 Class C - Chlorinated rubber-based compounds
24 - D5.5 Class D - Synthetic polymer compounds
25 - D5.6 Class Z - Other membrane-forming compounds
25 - D6 IMPREGNANTS
25 - D7 CURING COMPOUND CHOICE
25 - D8 APPLICATION
25 - D8.1 General
26 - D8.2 Methods of application
27 - D9 MISCELLANEOUS ASPECTS
27 - D9.1 Adhesion
27 - D9.2 Top-coating over concrete curing compounds
28 - D9.3 Heat reflectance
28 - D9.4 Drying time
28 - D9.5 Viscosity
28 - D9.6 Resilience
28 - D9.7 Flammability
28 - D9.8 Pollution
28 - D9.9 Storage
29 - D9.10 Safety
29 - D10 TESTING
29 - D10.1 Moisture retention
29 - D10.2 Uniformity testing
29 - D11 CONCLUSIONS AND RECOMMENDATIONS
30 - D12 REFERENCES

Specifies characteristics and requirements for liquid membrane-forming curing compounds for concrete (referred to as curing compounds). Such compounds are used to limit the loss of water from concrete surfaces during the early hydration method.

Committee
BD-033
DocumentType
Standard
ISBN
0 7337 2224 5
Pages
26
ProductNote
Reconfirmed 14/09/2018.
This standard has been reconfirmed in Australia in 2018 and remains current in New Zealand. Reconfirmation Notice 14/09/2018
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard sets out requirements for liquid membrane-forming curing compounds for concrete (referred to as curing compounds). It specifically excludes compounds applied to concrete, which do not form a membrane as defined in Clause 1.4, Definitions, of this Standard.Appendices set out sampling procedure, methods of test for water retention efficiency and drying time, and a final appendix discusses general information and properties of curing compounds.

Originated as AS 3799-1990.
Second edition 1998.

AS/NZS 1580.202.2:1995 Paints and related materials - Methods of test Density of water-dispersed paints subject to foaming (Reconfirmed 2013)
AS/NZS 1580.202.1:1995 Paints and related materials - Methods of test Density (Reconfirmed 2013)
AS 1216-2006 Class labels for dangerous goods
AS 2350.12-2006 Methods of testing portland, blended and masonry cements Preparation of a standard mortar and moulding of specimens
AS 3972-1997 Portland and blended cements
AS 1216-1995 Class labels for dangerous goods
AS 2350.12-1995 Methods of testing portland and blended cements Preparation of a standard mortar and moulding of specimens
AS/NZS 1580.214.5:1997 Paints and related materials - Methods of test Consistency - Rotational viscometer (Reconfirmed 2013)
AS 2701.7-1984 Methods of sampling and testing mortar for masonry construction Method for determination of water retention
AS/NZS 1580.211.1:1995 Paints and related materials - Methods of test Degree of settling (Reconfirmed 2013)
AS 1160-1996 Bituminous emulsions for the construction and maintenance of pavements
AS 1580.301.1-2005 Paints and related materials - Methods of test Non-volatile content by mass
AS 1580.301.1-1992 Paints and related materials - Methods of test Non-volatile content by mass

AS 1281-2001 Cement mortar lining of steel pipes and fittings (Reconfirmed 2018)
AS 1478.1-2000 Chemical admixtures for concrete, mortar and grout Admixtures for concrete (Reconfirmed 2018)
AS 5100.5-2004 Bridge design Concrete
AS 3600-2001 Concrete structures
AS 3600-1994 Concrete structures
AS 2870-2011 Residential slabs and footings
AS 5100.8:2017 Bridge design Rehabilitation and strengthening of existing bridges
AS 3600:2018 Concrete structures
HB 67-1995 Concrete practice on building sites
AS 5100.5:2017 Bridge design Concrete
AS 3600-2009 Concrete structures
AS/NZS 1516:1994 The cement mortar lining of pipelines in situ (Reconfirmed 2020)
AS 1281-1993 Cement mortar lining of steel pipes and fittings
AS 3727.1:2016 Pavements Residential
AS 3850-2003 Tilt-up concrete construction

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more