AS 3653-1993
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Boilers - Safety, management, combustion and other ancillary equipment
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
25-07-2024
English
01-01-1993
Specifies requirements for components, ancillary equipment, and management systems used as part of the boiler pressure and energy-generating system, including combustion equipment, water level security, safety valves and other fittings, blowdown connections and integral piping. Most of the requirements in This Standard are currently in AS 1228, Boilers - Water-tube, and AS 1797, Boilers - Fire-tube, shell and miscellaneous, with some requirements similar in both Standards, while others are different. The requirements have been reviewed, and as far as practicable, uniform requirements have been proposed in This Standard which will be applicable to all types of boilers. It is intended that all such requirements shall be withdrawn from AS 1228 and AS 1797 at their next revision.
Committee |
ME-001
|
DocumentType |
Standard
|
ISBN |
0 7262 8402 5
|
Pages |
28
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This Standard specifies the requirements for components, ancillary equipment and management systems used as a part of the boiler pressure and energy generating systems, including management systems, combustion equipment, water level security, safety valves, general valves and fittings, blowdown connections and integral piping.NOTE: Ancillary equipment and its installation, which form part of the support system, e.g. feed water supply, plant piping, and environmental equipment, are covered in AS 3892.This Standard is intended to-(a) establish the requirements for boiler management systems for all levels of automated operation, and to include controls, interlocks, electrical systems and other safety systems; (b) establish the minimum requisite fittings and valves such as safety valves and blowdown valves; (c) establish selection criteria for energy input equipment such as combustion equipment and the requirements for interfacing with the boiler design; and (d) form a bridge between the design codes (AS 1228, AS 1271, AS 1797) and AS 3892.
First published as AS 3653-1993.
AS 1431.2-1989 | Low voltage switchgear and controlgear - Control circuit devices and switching elements - Additional requirements for push-buttons and indicator lights |
AS 3158-1994 | Approval and test specification - Electric cables - Glass fibre insulated for working voltages up to and including 0.6/1 kV |
AS 3000-1986 | Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules) |
AS 1797-1986 | Boilers - Fire-tube, shell, and miscellaneous |
AS 1722.1-1975 | Pipe threads of Whitworth form Sealing pipe threads (metric units) |
AS 3147-1992 | Approval and test specification - Electric cables - Thermoplastic insulated - For working voltages up to and including 0.6/1 kV |
AS 1200-1988 | Boilers and pressure vessels (known as the SAA Boiler Code) |
AS 2052-1977 | Metallic conduits and fittings |
AS 1853-1983 | Automatic oil and gas burners - Mechanical draught |
AS 1722.2-1992 | Pipe threads of Whitworth form Fastening pipe threads (Reconfirmed 2017) |
AS 1029.1-1985 | Low voltage contactors - Electromechanical (up to and including 1000 V a.c. and 1200 V d.c.) |
AS 3178-1991 | Approval and test specification - Electric cables - Silicone rubber insulated - For working voltages up to and including 0.6/1 kV |
AS 1431.1-1989 | Low voltage switchgear and controlgear - Control circuit devices and switching elements - General requirements |
AS 1029.2-1982 | Low voltage contactors - Semiconductor (solid state) (up to and including 1000 V a.c. and 1500 V d.c.) |
AS 1074-1989 | Steel tubes and tubulars for ordinary service (Reconfirmed 2018) |
AS 3191-1981 | Approval and test specification for electric flexible cords (incorporating Corrigenda) |
AS 1210-1989 | |
AS 1271-1997 | Safety valves, other valves, liquid level gauges, and other fittings for boilers and unfired pressure vessels |
AS 3892-1995 | Pressure equipment - Installation |
AS 2593-1995 | Boilers - Unattended and limited attendance |
AS 1349-1986 | Bourdon tube pressure and vacuum gauges (Reconfirmed 2018) |
AS 1375-1985 | Industrial fuel-fired appliances (known as the SAA Industrial Fuel-fired Appliances Code) |
AS 1228-1997 | Pressure equipment - Boilers |
AS 3873-1995 | Pressure equipment - Operation and maintenance |
AS 3873-1995 | Pressure equipment - Operation and maintenance |
AS 2593-1995 | Boilers - Unattended and limited attendance |
AS/NZS 1200:1994 | Pressure equipment |
AS 1228-1997 | Pressure equipment - Boilers |
AS/NZS 3788:1996 | Pressure equipment - In-service inspection |
AS 3533.1-1997 | Amusement rides and devices Design and construction |
AS 3533.2-1997 | Amusement rides and devices Operation and maintenance |
AS 1271-1997 | Safety valves, other valves, liquid level gauges, and other fittings for boilers and unfired pressure vessels |
AS 2593-2001 | Boilers - Unattended and limited attendance |
AS 1210-1997 | Pressure vessels |
AS/NZS 3788:2001 | Pressure equipment - In-service inspection |
AS 3892-1995 | Pressure equipment - Installation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.