AS 2699.2:2020

Current

Current

The latest, up-to-date edition.

Built-in components for masonry construction Connectors and accessories

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

12-06-2020

Preview
$141.66
Including GST where applicable

This Standard specifies requirements for connectors and accessories built into masonry.

Committee
BD-028
DocumentType
Standard
ISBN
978 1 76072 872 4
Pages
43
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard specifies requirements for connectors and accessories built into masonry, including —
(a) masonry anchors;
(b) masonry connectors;
(c) masonry components other than wall ties;
(d) tie-downs in masonry;
(e) bolts and fixings in masonry;
(f) bed-joint mesh in masonry; and
(g) all accessories for masonry construction other than —
(i) wall ties that are covered by AS 2699.1;
(ii) lintels and shelf angles that are covered by AS 2699.3;
(iii) damp proof courses and flashings that are covered by AS/NZS 2904 and AS 3700;
(iv) termite protection that is covered by AS/NZS 3660 series; and
(v) mullions are covered by AS 3700.
NOTE 1 Bed-joint mesh is fabric laid in masonry bed joints as a tying material. This item does not include structural reinforcement in the bed joints of reinforced masonry.
NOTE 2 The design and installation of connectors and accessories are specified in AS 3700, AS 4773.1 (design) and AS 4773.2 (construction).
The requirements for connectors and accessories specified in this Standard cover —
(A) durability — materials specifications and test methods; and
(B) structural — test methods only.
NOTE 3 The durability classifications employed in this Standard are compatible with the environments specified in AS 3700, AS 4773.1, AS 4773.2, ISO 9223 and AS 4312—2008.
Because of the wide variety of connectors and accessories and their diverse applications, this Standard does not provide specifications for structural performance parameters. Test methods for these parameters are given for the guidance of manufacturers, designers and purchasers.
NOTE 4 Specifications for structural performance of components may be nominated by manufacturers, or negotiated between manufacturers, suppliers, designers and purchasers.
This Standard applies to connectors and accessories used in masonry described in AS 3700, AS 4773.1 and AS 4773.2.

First published in Australia as AS INT 325-1953.
Revised and redesignated as AS 2975-1987.
First published in New Zealand as NZS 4210:1989.
AS 2975-1987 and part of NZS 4210:1989 jointly revised and redesignated as AS/NZS 2699.2:2000.
AS/NZS 2699.2:2000 revised and redesignated as AS 2699.1:2020.

AS 4040.3:2018 Methods of testing sheet roof and wall cladding Resistance to wind pressures for cyclone regions
ASTM A 240/A240M : 2019 Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications
ISO 3951-2:2013 Sampling procedures for inspection by variables — Part 2: General specification for single sampling plans indexed by acceptance quality limit (AQL) for lot-by-lot inspection of independent quality characteristics
AS 2331.3.1-2001 Methods of test for metallic and related coatings Corrosion and related property tests - Neutral salt spray test (NSS test) (Reconfirmed 2017)
ISO 3951-3:2007 Sampling procedures for inspection by variables Part 3: Double sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
ASTM B 117 : 2019 Standard Practice for Operating Salt Spray (Fog) Apparatus
AS 2331.1.4-2001 Methods of test for metallic and related coatings Local thickness tests - Magnetic induction and eddy current methods
AS 3700:2018 Masonry Structures
ISO 2178:2016 Non-magnetic coatings on magnetic substrates Measurement of coating thickness Magnetic method
ISO 3951-5:2006 Sampling procedures for inspection by variables Part 5: Sequential sampling plans indexed by acceptance quality limit (AQL) for inspection by variables (known standard deviation)
AS/NZS 2904:1995 Damp-proof courses and flashings
ISO 9227:2017 Corrosion tests in artificial atmospheres — Salt spray tests
ISO 3951-1:2013 Sampling procedures for inspection by variables — Part 1: Specification for single sampling plans indexed by acceptance quality limit (AQL) for lot-by-lot inspection for a single quality characteristic and a single AQL
AS 2699.1:2020 Built-in components for masonry construction Wall ties
AS 3660.2:2017 Termite management In and around existing buildings and structures
AS 4773.1:2015 Masonry in small buildings Design
AS 3894.3-2002 Site testing of protective coatings Determination of dry film thickness (Reconfirmed 2013)
AS ISO/IEC 17025:2018 General requirements for the competence of testing and calibration laboratories
ISO 2859-1:1999 Sampling procedures for inspection by attributes — Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
AS 4773.2:2015 Masonry in small buildings Construction
AS 4312:2019 Atmospheric corrosivity zones in Australia
ISO 3951-4:2011 Sampling procedures for inspection by variables — Part 4: Procedures for assessment of declared quality levels
AS/NZS 4534:2006 Zinc and zinc/aluminium-alloy coatings on steel wire (Reconfirmed 2017)
AS 1397-2011 Continuous hot-dip metallic coated steel sheet and strip - Coatings of zinc and zinc alloyed with aluminium and magnesium
AS/NZS 4455.2:2010 Masonry units, pavers, flags and segmental retaining wall units Pavers and flags (Reconfirmed 2020)
AS/NZS 1170.2:2011 Structural design actions Wind actions (Reconfirmed 2016)
AS 3660.3:2014 Termite management Assessment criteria for termite management systems
ISO 9223:2012 Corrosion of metals and alloys — Corrosivity of atmospheres — Classification, determination and estimation
AS 3660.1:2014 Termite management New building work
AS/NZS 4680:2006 Hot-dip galvanized (zinc) coatings on fabricated ferrous articles (Reconfirmed 2017)
AS/NZS 4455.1:2008 Masonry units, pavers, flags and segmental retaining wall units Masonry units (Reconfirmed 2020)
AS/NZS 4455.3:2008 Masonry units, pavers, flags and segmental retaining wall units Segmental retaining wall units (Reconfirmed 2020)
ISO 19840:2012 Paints and varnishes — Corrosion protection of steel structures by protective paint systems — Measurement of, and acceptance criteria for, the thickness of dry films on rough surfaces

AS 2699.3:2020 Built-in components for masonry construction Lintels and shelf angles (durability requirements)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.