Insulation co-ordination Definitions, principles and rules
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
23-09-2024
05-03-1995
Specifies the procedure for the selection of the standard withstand voltages for the phase-to-earth, phase-to-phase and longitudinal insulation of the equipment and the installation of three-phase a.c. systems having a highest voltage for equipment above 1 kV. It also lists the standardized values from which the standard withstand voltages shall be selected. This Standard is technically equivalent to and has been reproduced from IEC 71-1:1993.
Committee |
EL-007
|
DocumentType |
Standard
|
ISBN |
0 7262 9571 X
|
Pages |
21
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This part of International Standard IEC 71 applies to three-phase a.c. systems having a highest voltage for equipment above 1 kV. It specifies the procedure for the selection of the standard withstand voltages for the phase-to-earth, phase-to-phase and longitudinal insulation of the equipment and the installations of these systems. It also gives the lists of the standardized values from which the standard withstand voltages shall be selected. This part recommends that the selected withstand voltages should be associated with the highest voltage for equipment. This association is for insulation co-ordination purposes only. The requirements for human safety are not covered by this Standard. Although the principles of this part also apply to transmission line insulation, the values of the withstand voltages may be different from the standard withstand voltages.The apparatus committees are responsible for specifying the withstand voltages and the test procedures suitable for the relevant equipment taking into consideration the recommendations of this Standard.NOTE û In IEC 71-2 Application Guide, (under revision), all rules for insulation co-ordination given in this Standard are justified in detail, in particular the association of the standard withstand voltages with the highest voltage for equipment. When more than one set of standard withstand voltages is associated with the same highest voltage for equipment, guidance is provided for the selection of the most suitable set.
Standards | Relationship |
IEC 60071-3:1982 | Identical |
IEC 60071-1:1993 | Identical |
First published as AS C337-1963.
Revised and redesignated AS 1824.1-1976.
Second edition 1985.
Third edition 1995.
AS 2926-1987 | Standard voltages - Alternating (50 Hz) and direct |
AS 1931.1-1996 | High-voltage test techniques - General definitions and test requirements |
AS/NZS 2081.5:2002 | Electrical equipment for coal and shale mines - Electrical protection devices - Earth-fault current limiters |
AS 1137.3-1981 | Insulators - Porcelain and glass indoor and outdoor station post insulators (for voltages greater than 1000 V a.c.) |
AS 60044.2-2007 | Instrument transformers Inductive voltage transformers (IEC 60044-2:Ed.1.2 (2003) MOD) |
AS 2735-1984 | Dry-type power transformers |
AS 3007.2-2004 | Electrical installations - Surface mines and associated processing plant - General protection requirements |
AS 1265-1990 | Bushings for alternating voltages above 1000 V |
AS/NZS 60137:2008 | Insulated bushings for alternating voltages above 1000 V (IEC 60137, Ed. 5.0 (2003) MOD) |
AS/NZS 60076.3:2008 | Power transformers Insulation levels, dielectric tests and external clearances in air (IEC 60076-3, Ed. 2 (2000) MOD) |
AS/NZS 4871.1:2010 | Electrical equipment for mines and quarries General requirements |
AS 1824.2-1985 | Insulation coordination (phase-to-earth and phase-to-phase, above 1 kV) - Application guide |
AS 1418.10(INT)-2004 | Cranes, hoists and winches Elevating work platforms |
AS 2067-1984 | Switchgear assemblies and ancillary equipment for alternating voltages above 1 kV |
AS 60044.1-2007 | Instrument transformers Current transformers (IEC 60044-1 Ed.1.2 (2003) MOD) (Reconfirmed 2016) |
AS/NZS 2947.2:2002 | Insulators - Porcelain and glass for overhead power lines - Voltages greater than 1000 V a.c. |
AS/NZS 60265.1:2001 | High-voltage switches Switches for rated voltages above 1 kV and less than 52 kV (IEC 60265-1:1998, MOD) (Reconfirmed 2016) |
AS 4899-2007 | Pin insulators - Porcelain and glass for overhead power lines - Voltages greater than 1000 V a.c. (Reconfirmed 2018) |
AS/NZS 1418.10:2011 | Cranes, hoists and winches Mobile elevating work platforms |
AS 62103-2006 | Electronic equipment for use in power installations |
AS 3439.1-1993 | Low-voltage switchgear and controlgear assemblies Type-tested and partially type-tested assemblies |
AS 60038-2012 | Standard voltages |
AS/NZS 2650:2000 | Common specifications for high-voltage switchgear and controlgear standards |
AS 2067-2008 | Substations and high voltage installations exceeding 1 kV a.c. |
AS 60204.11-2006 | Safety of machinery - Electrical equipment of machines Requirements for HV equipment for voltages above 1000 V a.c. or 1500 V d.c and not exceeding 36 kV (IEC 60204-11, Ed. 1.0 (2000) MOD) |
AS 60044.5-2004 | Instrument transformers Capacitor voltage transformers |
AS 2374.3.1-1992 | Power transformers Insulation levels and dielectric test - External clearances in air |
AS 4398.1-1996 | Insulators - Ceramic or glass - Station post for indoor and outdoor use - Voltages greater than 1000 V a.c. Characteristics (Reconfirmed 2016) |
AS 1243-1982 | Voltage transformers for measurement and protection |
AS/NZS 3947.1:1998 | Low-voltage switchgear and controlgear General rules |
AS/NZS 2947.4:1999 | Insulators - Porcelain and glass for overhead power lines - Voltages greater than 1000 V a.c. Test methods - Insulator strings and insulator sets |
AS 2374.3.0-1982 | Power transformers Insulation levels and dielectric tests - General requirements |
AS IEC 60433-2007 | Insulators for overhead lines with a nominal voltage above 1000 V - Ceramic insulators for a.c. systems - Characteristics of insulator units of the long rod type |
AS 2067:2016 | Substations and high voltage installations exceeding 1 kV a.c. |
AS 3851-1991 | The calculation of short-circuit currents in three-phase a.c. systems (Reconfirmed 2015) |
AS 60265.2-2005 | High-voltage switches High-voltage switches for rated voltages of 52 kV and above (IEC 60265-2, Ed.1.0(1988) MOD) |
AS 3947.1-1993 | Low-voltage switchgear and controlgear General rules |
AS 4398.2-1996 | Insulators - Ceramic or glass - Station post for indoor and outdoor use - Voltages greater than 1000 V a.c. Tests |
AS 1931.2-1996 | High-voltage test techniques - Measuring systems |
AS 4398.2-2005 | Insulators - Ceramic or glass - Station post for indoor or outdoor use - Voltages greater than 1000 V a.c. Tests (IEC 60168, Ed. 4.2 (2001) MOD) |
AS 2897-1986 | Power capacitors - Shunt - Rated voltages above 660 v a.c. |
AS/NZS 3439.1:2002 | Low-voltage switchgear and controlgear assemblies Type-tested and partially type tested assemblies (IEC 60439-1:1999 MOD) |
AS 2650-2005 | Common specifications for high-voltage switchgear and controlgear standards (IEC 60694 Ed.2.2(2002) MOD) |
AS/NZS 4871.1:2012 | Electrical equipment for mines and quarries General requirements |
AS/NZS 3947.1:2001 | Low-voltage switchgear and controlgear General rules |
AS/NZS 3007:2013 | Electrical equipment in mines and quarries - Surface installations and associated processing plant |
AS 60947.1-2004 | Low-voltage switchgear and controlgear General rules |
AS 1025.2-1989 | High-voltage a.c. switchgear and controlgear - Switches and switch-disconnectors - For rated voltages of 52 kV and above |