AS 1668.3-2001

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

The use of ventilation and airconditioning in buildings Smoke control systems for large single compartments or smoke reservoirs

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

25-07-2024

Language(s)

English

Published date

17-12-2001

Preview
$230.65
Including GST where applicable

This Standard sets minimum requirements for the design of smoke control systems in large single compartments in which smoke accumulates in a smoke reservoir. It sets minimum requirements considered necessary to meet the system design objectives in terms of continuous operation over a specified time period under a specified fire condition. The design information given in This Standard is based on axisymmetric plumes. Compartments and smoke reservoirs are designed separately and spill plumes between compartments/reservoirs are not considered. Application of this Standard is not appropriate in situations where a stable buoyant hot layer does not exist.

Committee
ME-062
DocumentType
Standard
ISBN
0 7337 3733 1
Pages
82
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets minimum requirements for the design of smoke control systems in large single compartments in which smoke accumulates in a smoke reservoir. It sets minimum requirements considered necessary to meet the system design objectives in terms of continuous operation over a specified time period under a specified fire condition.The design information given in this Standard is based on axisymmetric plumes. Compartments and smoke reservoirs are designed separately and spill plumes between compartments/reservoirs are not considered.This Standard is not appropriate in situations where a stable buoyant hot layer does not exist.NOTES: 1 Smoke control in multi-compartment buildings is covered in AS/NZS 1668.1.2 This Standard should only be applied to areas with greater than 3 m floor to ceiling or upper bounding layer height.3 AS 1851.5 and AS/NZS 1851.6 outline management procedures for maintaining smoke and heat vents and the fire and smoke control features of air-handling systems.

First published as AS 1668.3-2001.

AS 2118.1-1999 Automatic fire sprinkler systems General requirements
AS 1851.5-1981 Maintenance of fire protection equipment - Automatic smoke/heat venting systems
AS/NZS 3013:1995 Electrical installations - Classification of the fire and mechanical performance of wiring systems
AS 1170.2-1989 Minimum design loads on structures (known as the SAA Loading Code) Wind loads
AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 2427-1983 Smoke/heat release vents
AS 1170.1-1989 Minimum design loads on structures (known as the SAA Loading Code) Dead and live loads and load combinations
AS 1530.3-1989 Methods for fire tests on building materials, components and structures Simultaneous determination of ignitability, flame propagation, heat release and smoke release
AS 1670.1-1995 Fire detection, warning, control and intercom systems - System design, installation and commissioning Fire
AS 2428.5-1983 Methods of testing smoke/heat release vents Determination of discharge coefficient and effective aerodynamic area
AS 1851.6-1997 Maintenance of fire protection equipment - Management procedures for maintaining the fire and smoke control features of air-handling systems
AS 4391-1999 Smoke management systems - Hot smoke test (Reconfirmed 2016)
AS 1530.1-1994 Methods for fire tests on building materials, components and structures Combustibility test for materials (Reconfirmed 2016)
AS 2419.1-1994 Fire hydrant installations System design, installation and commissioning
AS 2220.2-1989 Emergency warning and intercommunication systems in buildings System design, installation and commissioning
AS 1530.2-1993 Methods for fire tests on building materials, components and structures Test for flammability of materials (Reconfirmed 2016)
AS 2047-1999 Windows in buildings - Selection and installation
AS 4429-1999 Methods of test and rating requirements for smoke-spill fans (Reconfirmed 2016)
AS/NZS 1668.1:1998 The use of ventilation and airconditioning in buildings Fire and smoke control in multi-compartment buildings
AS 2484.1-1990 Fire - Glossary of terms Fire tests (Reconfirmed 2016)
AS 1562.1-1992 Design and installation of sheet roof and wall cladding Metal (Reconfirmed 2016)
AS 1170.3-1990 Minimum design loads on structures (known as the SAA Loading Code) - Snow loads

AS 1851-2012 Routine service of fire protection systems and equipment
AS 1188-1990 Radio transmitters and similar equipment - Safe practices
AS 1851-2005 Maintenance of Fire Protection Systems and Equipment

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more