AS 1531-1991
Current
The latest, up-to-date edition.
Conductors - Bare overhead - Aluminium and aluminium alloy (Reconfirmed 2016)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
10-06-1991
Sets out requirements and tests necessary for homogeneous bare electrical conductors for overhead power transmission and constructed of all aluminium and aluminium alloy wires. A range of wire sizes, 2.50mm to 4.75mm, and their properties are provided.
Committee |
EL/10
|
DocumentType |
Standard
|
ISBN |
0 7262 6881 X
|
Pages |
12
|
ProductNote |
Reconfirmed 27/05/2016.This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand. Reconfirmation Notice 27/05/2016
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This Standard specifies requirements and tests for homogeneous bare electrical conductors for overhead power transmission, and constructed of all aluminium or all aluminium alloy wires.NOTES:1 Appendix A gives methods to calculate conductor properties.2 Appendix B gives the coefficient of linear expansion and the theoretical basis for the calculation of modulus of elasticity.3 Appendix C lists code names which may be used to refer to specific type and construction of conductor.4 Appendix D lists information which should be supplied with enquiries and orders for conductors.
AS 1531 first published as part of AS C75-1936 (endorsement of BS 215-1932 without amendment).
AS C75-1936 revised and redesignated in part as AS C75.2-1965.
Revised and redesignated AS 1531.1-1974.
AS C75.3 first published 1965.
Revised and redesignated AS 1531.2-1974.
AS 1531.3 first published 1984.
AS 1531.1-1974, AS 1531.2-1974 and AS 1531.3-1984 revised, amalgamated and redesignated AS 1531-1991.
AS 1391-2007 | Metallic materials - Tensile testing at ambient temperature (Reconfirmed 2017) |
AS 2505.5-1982 | Methods for bend and related testing of metals - Torsion and wrapping tests on wire |
AS/NZS 2857:1996 | Timber drums for insulated electric cables and bare conductors |
AS 2857-1986 | Timber drums for insulated electric cables and bare conductors |
AS 2505.5-2002 | Metallic materials Wire - Simple torsion test |
AS 2848.1-1998 | Aluminium and aluminium alloys - Compositions and designations Wrought products (Reconfirmed 2018) |
AS 1391-1991 | Methods for tensile testing of metals |
AS C365.2-1970 | Drums for bare stranded conductors - Metal drums |
AS/NZS 3599.2:1999 | Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11(12) kV and 12.7/22(24) kV Non-metallic screened |
AS 3822(INT)-1998 | Test methods for bare overhead conductors |
AS/NZS 1768:2007 | Lightning protection |
AS/NZS 7000:2016 | Overhead line design |
AS/NZS 3008.1.1:2017 | Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions |
AS 3822-2002 | Test methods for bare overhead conductors |
HB 331-2012 | Overhead line design |
AS/NZS 3008.1.2:2010 | Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions |
DR 00391 | Conductors - Covered overhead - For working voltages 6.35/11(12)kV up to and including 19/33(36)kV |
AS/NZS 3008.1.2:1998 | Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand installation conditions |
AS/NZS 7000:2010 | Overhead line design - Detailed procedures |
AS/NZS 3008.1.1:2009 | Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions |
AS/NZS 3675:2002 | Conductors - Covered overhead - For working voltages 6.35/11 (12) kV up to and including 19/33 (36) kV (Reconfirmed 2017) |
AS/NZS 3008.1.1:1998 | Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions |
AS/NZS 3008.1.2:2017 | Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions |
AS 3675-1993 | Conductors - Covered overhead - For working voltages 6.35/11 kV up to and including 19/33 kV |
AS/NZS 1768(INT):2003 | Lightning protection |