AS 1289.5.7.1-2006
Current
The latest, up-to-date edition.
Methods of testing soils for engineering purposes Soil compaction and density tests - Compaction control test - Hilf density ratio and Hilf moisture variation (rapid method)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
07-06-2006
This Standard sets out a rapid method for determining compaction control parameters for soils. The method involves relating converted wet density (CWD) of the laboratory compacted soil to added moisture (Z) without the need to determine moisture content.
Committee |
CE-009
|
DocumentType |
Standard
|
ISBN |
0 7337 7479 2
|
Pages |
8
|
ProductNote |
Pending Revision indicates that as a result of the Aged Standards review process, the document needs updating. If no project proposal, meeting the quality criteria, is received within the 12 month timeframe, the document shall be withdrawn.
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This Standard sets out a rapid method for determining compaction control parameters for soils. The method involves relating converted wet density (CWD) of the laboratory-compacted soil to added moisture (Z) without the need to determine moisture content.The test is based on standard compactive effort in accordance with AS 1289.5.1.1. If modified compactive effort in accordance with AS 1289.5.2.1 is used, experimental data must initially be accumulated for that particular soil in order for the moisture variation to be reliably assessed (see Note to Clause 4.2(h)).Because this is a rapid method, there may be minor differences between results obtained by this procedure and results obtained by the method of compaction control given in AS 1289.5.4.1.This procedure is applicable to the portion of soil that passes a 37.5 mm sieve. Corrections can be made to values determined by this method for soil with up to 20% oversize material. Soil that passes a 19.0 mm sieve is compacted in a 105 mm diameter mould. Soil that contains more than 20% of material retained on a 19.0 mm sieve is compacted in a 152 mm diameter mould.Because of the omission of proper curing, this method might not be reliable for soils that are much wetter or drier than the optimum moisture content.Further, because of the empirical basis for the calculation of moisture variation, the method is limited to added moisture values (Z) between (4% and +6% (see Figure 1).This method may be used for checking material before placement to ensure that the moisture content is within specified limits (see Note to Clause 4.2(h)).
First published as AS A89.21-1973.
Revised and redesignated AS 1289.E7.1-1977.
Revised and redesignated AS 1289.5.7.1-1993.
Second edition 2006.
AS 1289.1.1-2001 | Methods of testing soils for engineering purposes Sampling and preparation of soils - Preparation of disturbed soil samples for testing |
AS 1289.5.4.1-2007 | Methods of testing soils for engineering purposes Soil compaction and density tests - Compaction control test - Dry density ratio, moisture variation and moisture ratio (Reconfirmed 2016) |
AS 1289.5.3.1-2004 | Methods of testing soils for engineering purposes Soil compaction and density tests - Determination of the field density of a soil - Sand replacement method using a sand-cone pouring apparatus (Reconfirmed 2016) |
AS 1289.5.4.1-1993 | Methods of testing soils for engineering purposes Soil compaction and density tests - Compaction control test - Dry density ratio, moisture variation and moisture ratio |
AS 1289.5.1.1-2003 | Methods of testing soils for engineering purposes Soil compaction and density tests - Determination of the dry density/moisture content relation of a soil using standard compactive effort |
AS 1289.5.3.5-1997 | Methods of testing soils for engineering purposes Soil compaction and density tests - Determination of the field dry density of a soil - Water replacement method (Reconfirmed 2013) |
AS 1289.5.2.1-2003 | Methods of testing soils for engineering purposes Soil compaction and density tests - Determination of the dry density or moisture content relation of a soil using modified compactive effort |
AS 1152-1993 | Specification for test sieves |
AS 1289.5.8.1-2007 | Methods of testing soils for engineering purposes Soil compaction and density tests - Determination of field density and field moisture content of a soil using a nuclear surface moisture-Density gauge - Direct transmission mode |
AS 1289.5.8.1-1995 | |
AS 1289.5.3.2-2004 | Methods of testing soils for engineering purposes Soil compaction and density tests - Determination of the field density of a soil - Sand replacement method using a sand pouring can, with or without a volume displacer (Reconfirmed 2016) |
HB 160-2006 | Soils testing |
AS/NZS 3500.5:2012 | Plumbing and drainage Housing installations |
AS/NZS 3725:2007 | Design for installation of buried concrete pipes |
AS 3798-2007 | Guidelines on earthworks for commercial and residential developments |
AS 1289.5.2.1:2017 | Methods of testing soils for engineering purposes Soil compaction and density tests - Determination of the dry density/moisture content relation of a soil using modified compactive effort |
AS 1289.5.1.1:2017 | Methods of testing soils for engineering purposes Soil compaction and density tests - Determination of the dry density/moisture content relation of a soil using standard compactive effort |
AS 3727.1:2016 | Pavements Residential |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.