1 General
    1.1 Scope
    1.2 Definitions
    1.3 Referenced American National Standards
2 General Test Conditions
3 Conformance Tests
    3.1 General
    3.2 Test Requirements
    3.3 Test Arrangements
    3.4 Grouping of Ratings for Test Purposes
    3.5 Impulse Withstand Tests
    3.6 Continuous Current Tests
    3.7 No Load Mechanical Operations Tests
    3.8 Load Current Switching Tests
    3.9 Short time Current Carrying Tests
    3.10 Short Circuit Current Tests
4 Circuit Breaker Auxiliary Devices
    4.1 General
    4.2 Auxiliary Switches
    4.3 Other Components and Features
5 Treatment of Failures
6 Production Tests
    6.1 General
    6.2 Power Frequency Voltage Withstand Tests
    6.3 Conductivity of Current Path Tests
    6.4 Control Devices and Secondary Wiring Tests
    6.5 Bushing Tests
    6.6 Mechanical Operations Tests
    6.7 Timing Tests
    6.8 Pressure and Leakage Tests
7 Production Monitoring and Product Retest Requirements
    7.1 General
    7.2 Production Monitoring
    7.3 Product Retest Requirements
8 Conformance Test Records
Tables
1 Test Schedules
2 Typical Grouping of Ratings for Test Purposes
3 Test Duties
4 Auxiliary Switch Tests
5 Retest Intervals for Typical Test Groups
6 Retest Intervals for Combined Groups

Defines tests for demonstrating that the circuit breaker testing conforms with the ratings assigned to it according to ANSI C37.06 when applied to indoor alternating current medium voltage circuit breakers rated in excess of 1000 volts, to be used as removable elements in metal-enclosed switchgear assemblies according to clause 2.1.9.3. of ANSI/IEEE C37.20.2. Not applicable to installations exclusively controlled by electric utilities for communication purposes, or metering or for generating, controlling, transforming, transmitting and distributing of electric energy in buildings for the exclusive use of utilities for such purposes, or on property loaned or leased by the utility or on public highways.

DocumentType
Standard
Pages
37
PublisherName
National Electrical Manufacturers Association
Status
Superseded
SupersededBy

IEEE DRAFT C37.09 : D03F JAN 99 TEST PROCEDURE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS
MIL-DTL-32485 Base Document:2013 CIRCUIT BREAKERS, VACUUM TYPE (VCB), ELECTRIC POWER, MEDIUM VOLTAGE, ALTERNATING CURRENT, DRAW-OUT REMOVABLE CONSTRUCTION, WITHOUT INTERNAL OVERCURRENT PROTECTION
IEEE C37.20.2-2015 IEEE Standard for Metal-Clad Switchgear
ANSI C37.55 : 1989 MEDIUM VOLTAGE METAL-CLAD ASSEMBLIES - CONFORMANCE TEST PROCEDURES
NEMA SG 5-1995 POWER SWITCHGEAR ASSEMBLIES
UL 1008A:2ED 2017-09-05 Transfer Switch Equipment, Over 1000 Volts
CSA C22.2 NO. 178.3:17 Transfer switch equipment, over 1000 volts (Binational standard with UL 1008A)
IEEE C37.04-1999 IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers
IEEE C37.09-1999 IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis

IEEE C37.20.2-2015 IEEE Standard for Metal-Clad Switchgear
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
ANSI C37.55 : 1989 MEDIUM VOLTAGE METAL-CLAD ASSEMBLIES - CONFORMANCE TEST PROCEDURES
IEEE C37.06-2009 AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - PREFERRED RATINGS AND RELATED REQUIRED CAPABILITIES
IEEE C37.09-1999 IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis
IEEE C37.04-1999 IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.