AAMI ISO 14937:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
STERILIZATION OF HEALTH CARE PRODUCTS - GENERAL REQUIREMENTS FOR CHARACTERIZATION OF A STERILIZING AGENT AND THE DEVELOPMENT, VALIDATION AND ROUTINE CONTROL OF A STERILIZATION PROCESS FOR MEDICAL DEVICES
Hardcopy , PDF
31-08-2021
English
01-01-2013
Glossary of equivalent standards
Committee representation
Background of ANSI/AAMI adoption of ISO 14937:2009
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Quality management system elements
5 Sterilizing agent characterization
6 Process and equipment characterization
7 Product definition
8 Process def
9 Validation
10 Routine monitoring and control
11 Product release from sterilization
12 Maintaining process effectiveness
Annex A (normative) - Factors to be considered in selection
of microorganisms for demonstrating
microbicidal effectiveness
Annex B (normative) - Approach 1 - Process definition based
on inactivation of the microbial
population in its natural state
Annex C (normative) - Approach 2 - Process definition based
on inactivation of reference
microorganisms and knowledge of bioburden
Annex D (normative) - Approach 3 - Conservative process
definition based on inactivation of
reference microorganisms
Annex E (informative) - Guidance on application of this
International Standard
Bibliography
Describes general requirements for the characterization of a sterilizing agent and for the development, validation and routine monitoring and control of a sterilization process for medical devices.
Committee |
WG 11
|
DocumentType |
Standard
|
Pages |
53
|
ProductNote |
Reconfirmed 2009
|
PublisherName |
Association for the Advancement of Medical Instrumentation
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
ISO 14937:2009 | Identical |
AAMI TIR16:2023 | Microbiological aspects of ethylene oxide sterilization |
IEC 61010-2-040:2015 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ISO 11137-1:2006 | Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO 11607-2:2006 | Packaging for terminally sterilized medical devices Part 2: Validation requirements for forming, sealing and assembly processes |
ISO 14160:2011 | Sterilization of health care products Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives Requirements for characterization, development, validation and routine control of a sterilization process for medical devices |
ISO 11737-2:2009 | Sterilization of medical devices Microbiological methods Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process |
ISO 11737-1:2006 | Sterilization of medical devices Microbiological methods Part 1: Determination of a population of microorganisms on products |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
ISO 22442-1:2015 | Medical devices utilizing animal tissues and their derivatives Part 1: Application of risk management |
ISO 11135-1:2007 | Sterilization of health care products Ethylene oxide Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO 11140-1:2014 | Sterilization of health care products Chemical indicators Part 1: General requirements |
ISO 9004:2009 | Managing for the sustained success of an organization A quality management approach |
ISO 20857:2010 | Sterilization of health care products Dry heat Requirements for the development, validation and routine control of a sterilization process for medical devices |
ISO/TS 11139:2006 | Sterilization of health care products Vocabulary |
ISO 10993-17:2002 | Biological evaluation of medical devices — Part 17: Establishment of allowable limits for leachable substances |
ISO 11137-2:2013 | Sterilization of health care products — Radiation — Part 2: Establishing the sterilization dose |
ISO 14001:2015 | Environmental management systems — Requirements with guidance for use |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
ISO 10012:2003 | Measurement management systems — Requirements for measurement processes and measuring equipment |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 22442-2:2015 | Medical devices utilizing animal tissues and their derivatives Part 2: Controls on sourcing, collection and handling |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
ISO 11138-1:2017 | Sterilization of health care products — Biological indicators — Part 1: General requirements |
ISO 22442-3:2007 | Medical devices utilizing animal tissues and their derivatives — Part 3: Validation of the elimination and/or inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO 11607-1:2006 | Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems |
ISO/IEC 90003:2014 | Software engineering Guidelines for the application of ISO 9001:2008 to computer software |
ISO 14161:2009 | Sterilization of health care products Biological indicators Guidance for the selection, use and interpretation of results |
ISO 14040:2006 | Environmental management Life cycle assessment Principles and framework |
ISO 17664:2017 | Processing of health care products Information to be provided by the medical device manufacturer for the processing of medical devices |
ISO 17665-1:2006 | Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.