17/30361391 DC : 0
NA
Status of Standard is Unknown
BS EN 50174-2 - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS
Hardcopy , PDF
English
European foreword
Introduction
1 Scope and conformance
2 Normative references
3 Terms, definitions and abbreviations
4 Requirements for planning installations of
information technology cabling
5 Requirements for the installation of information
technology cabling
6 Segregation of metallic information technology
cabling and power supply cabling
7 Electricity distribution systems and lightning
protection
8 Office (commercial) spaces
9 Industrial spaces
10 Homes
11 Data centre spaces
12 Cabling for distributed services cabling within
buildings
13 Common infrastructures within multi-tenant
buildings
Annex A (informative) - EMC and protection
Annex B (informative) - Application of responsibilities
Annex C (informative) - Installation conditions
Annex D (informative) - Equipment accommodation
environments
Bibliography
BS EN 50174-2.
Committee |
TCT/7
|
DocumentType |
Draft
|
Pages |
124
|
PublisherName |
British Standards Institution
|
Status |
NA
|
Standards | Relationship |
PREN 50174-2 : DRAFT 2017 | Identical |
IEC 61537:2006 | Cable management - Cable tray systems and cable ladder systems |
IEC TR 61000-5-3:1999 | Electromagnetic compatibility (EMC) - Part 5-3: Installation and mitigation guidelines - HEMP protection concepts |
IEC 60364-5-534:1997 | Electrical installations of buildings - Part 5: Selection and erection of electrical equipment - Section 534: Devices for protection against overvoltages |
IEC 60364-5-54:2011 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
IEC 60825-2:2004+AMD1:2006+AMD2:2010 CSV | Safety of laser products - Part 2: Safety of optical fibre communication systems (OFCS) |
IEC 61158-2:2014 | Industrial communication networks - Fieldbus specifications - Part 2: Physical layer specification and service definition |
EN 62368-1:2014/AC:2017-03 | AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS (IEC 62368-1:2014, MODIFIED) |
IEC 61784-1:2014 | Industrial communication networks - Profiles - Part 1: Fieldbus profiles |
HD 60364-4-443:2016 | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances - Clause 443: Protection against transient overvoltages of atmospheric origin or due to switching |
EN 61784-3:2016/A1:2017 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3: FUNCTIONAL SAFETY FIELDBUSES - GENERAL RULES AND PROFILE DEFINITIONS (IEC 61784-3:2016/A1:2017) |
EN 62305-4:2011/AC:2016 | PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES (IEC 62305-4:2010) |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
EN 61558-1:2005/A1:2009 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
IEC 60079-17:2013 | Explosive atmospheres - Part 17: Electrical installations inspection and maintenance |
EN 62949:2017 | Particular safety requirements for equipment to be connected to information and communication networks |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
HD 60364-5-54:2011/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
EN 13501-6:2014 | Fire classification of construction products and building elements - Part 6: Classification using data from reaction to fire tests on electric cables |
CLC/TR 50174-99-1:2015 | Information technology - Cabling installation - Part 99-1: Remote powering |
IEC 62949:2017 | Particular safety requirements for equipment to be connected to information and communication technology networks |
PREN 50174-1 : DRAFT 2017 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
EN 50491-6-1:2014 | General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 6-1: HBES installations - Installation and planning |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
EN 50700:2014 | Information technology - Premises distribution access network (PDAN) cabling to support deployment of optical broadband networks |
EN 50173-3 : 2007 COR 2011 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 3: INDUSTRIAL PREMISES |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
EN 50174-3:2013/A1:2017 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
EN 61386-1:2008 | Conduit systems for cable management - Part 1: General requirements |
EN 50173-1:2011 | Information technology - Generic cabling systems - Part 1: General requirements |
EN 50085-1 : 2005 AMD 1 2013 | CABLE TRUNKING SYSTEMS AND CABLE DUCTING SYSTEMS FOR ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS |
EN 62305-3:2011 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
HD 60364-5-534:2016 | Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control - Clause 534: Devices for protection against transient overvoltages |
IEC 61558-1:2017 | Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
IEC 61918:2013 | Industrial communication networks - Installation of communication networks in industrial premises |
HD 60364-1:2008/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 1: FUNDAMENTAL PRINCIPLES, ASSESSMENT OF GENERAL CHARACTERISTICS, DEFINITIONS |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 50600-2-5:2016 | Information technology - Data centre facilities and infrastructures - Part 2-5: Security systems |
EN 50600-2-4:2015 | Information technology - Data centre facilities and infrastructures - Part 2-4: Telecommunications cabling infrastructure |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
EN 61784-3-1:2010 | Industrial communication networks - Profiles - Part 3-1: Functional safety fieldbuses - Additional specifications for CPF 1 |
EN 62305-2:2012 | Protection against lightning - Part 2: Risk management |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
EN 61300-3-35:2015 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-35: Examinations and measurements - Visual inspection of fibre optic connectors and fibre-stub transceivers |
IEC 60364-4-443:1995+AMD1:1998 CSV | Electrical installations of buildings - Part 4: Protection for safety - Chapter 44: Protection against overvoltages - Section 443: Protection against overvoltages of atmospheric origin or due to switching |
EN 60079-14:2014/AC:2016 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016) |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
EN 61918:2013/AC:2014 | INDUSTRIAL COMMUNICATION NETWORKS - INSTALLATION OF COMMUNICATION NETWORKS IN INDUSTRIAL PREMISES (IEC 61918:2013, MODIFIED) |
EN 61158-2:2014 | Industrial communication networks - Fieldbus specifications - Part 2: Physical layer specification and service definition |
IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 61386-1:2008+AMD1:2017 CSV | Conduit systems for cable management - Part 1: General requirements |
EN 60079-17:2014 | Explosive atmospheres - Part 17: Electrical installations inspection and maintenance |
IEC 62305-2:2010 | Protection against lightning - Part 2: Risk management |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 61784-2:2014 | Industrial communication networks - Profiles - Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3 |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 60825-2:2004/A2:2010 | SAFETY OF LASER PRODUCTS - PART 2: SAFETY OF OPTICAL FIBRE COMMUNICATION SYSTEMS (OFCS) |
EN 50090-9-1:2004 | Home and Building Electronic Systems (HBES) - Part 9-1: Installation requirements - Generic cabling for HBES Class 1 Twisted Pair |
EN 61537:2007 | Cable management - Cable tray systems and cable ladder systems |
EN 50173-5 : 2007 AMD 2 2012 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 5: DATA CENTRES |
EN 50173-4 : 2007 AMD 2 2012 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 4: HOMES |
EN 61784-1:2014 | Industrial communication networks - Profiles - Part 1: Fieldbus profiles |
EN 50310:2016 | Telecommunications bonding networks for buildings and other structures |
IEC 61784-3-1:2010 | Industrial communication networks - Profiles - Part 3-1: Functional safety fieldbuses - Additional specifications for CPF 1 |
IEC 62305-3:2010 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
EN 50173-6:2013 | Information technology - Generic cabling systems - Part 6: Distributed building services |
IEC 62368-1:2014 | Audio/video, information and communication technology equipment - Part 1: Safety requirements |
CLC/TS 61643-22:2016 | Low-voltage surge protective devices - Part 22: Surge protective devices connected to telecommunications and signalling networks - Selection and application principles |
IEC 61784-3:2016+AMD1:2017 CSV | Industrial communication networks - Profiles - Part 3: Functional safety fieldbuses - General rules and profile definitions |
IEC 61784-2:2014 | Industrial communication networks - Profiles - Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3 |
EN 50117-4-1 : 2008 AMD 1 2013 | COAXIAL CABLES - PART 4-1: SECTIONAL SPECIFICATION FOR CABLES FOR BCT CABLING IN ACCORDANCE WITH EN 50173 - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.