BS ISO/ASTM 51649 - PRACTICE FOR DOSIMETRY IN AN ELECTRON BEAM FACILITY FOR RADIATION PROCESSING AT ENERGIES BETWEEN 300 KEV AND 25 MEV
Hardcopy , PDF
English
1 Scope
2 Referenced documents
3 Terminology
4 Significance and use
5 Radiation source characteristics
6 Documentation
7 Dosimetry system selection and calibration
8 Installation qualification
9 Operational qualification
10 Performance qualification
11 Routine process control
12 Certification
13 Measurement uncertainty
14 Keywords
ANNEXES (informative) -
A1 - TYPES OF ELECTRON BEAM FACILITIES
A2 - ELECTRON BEAM DEPTH-DOSE DISTRIBUTIONS
A3 - MEASUREMENT OF DEPTH-DOSE DISTRIBUTION
A4 - CALCULATION OF ELECTRON BEAM ENERGY BASED
ON MEASURED DEPTH-DOSE DISTRIBUTION
A5 - ABSORBED DOSE AS FUNCTION OF BEAM CURRENT,
BEAM WIDTH AND CONVEYOR SPEED
A6 - MEASUREMENT OF BEAM WIDTH AND DOSE UNIFORMITY
ALONG SCAN DIRECTION
A7 - DOSE DISTRIBUTIONS FOR SCANNED AND PULSED BEAMS
A8 - DOSE DISTRIBUTION IN REFERENCE MATERIAL
A9 - PROCESS INTERRUPTION
A10 - MATERIAL PROCESSING RATES
A11 - TABLE A2 FROM ISO 11137-1
Bibliography
BS ISO/ASTM 51649.
Committee |
NCE/2
|
DocumentType |
Draft
|
Pages |
44
|
PublisherName |
British Standards Institution
|
Status |
NA
|
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ISO 11137-1:2006 | Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO/ASTM 51702:2013 | Practice for dosimetry in a gamma facility for radiation processing |
ISO/ASTM 51818:2013 | Practice for dosimetry in an electron beam facility for radiation processing at energies between 80 and 300 keV |
ISO/ASTM 51261:2013 | Practice for calibration of routine dosimetry systems for radiation processing |
ISO/ASTM 51275:2013 | Practice for use of a radiochromic film dosimetry system |
ISO/ASTM 51608:2015 | Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing at energies between 50 keV and 7.5 MeV |
ASTM F 1356 : 2016 : REDLINE | Standard Guide for Irradiation of Fresh, Frozen or Processed Meat and Poultry to Control Pathogens and Other Microorganisms |
ASTM E 170 : 2017 : REDLINE | Standard Terminology Relating to Radiation Measurements and Dosimetry |
ASTM E 2232 : 2016 : REDLINE | Standard Guide for Selection and Use of Mathematical Methods for Calculating Absorbed Dose in Radiation Processing Applications |
ISO/ASTM 51539:2013 | Guide for use of radiation-sensitive indicators |
ISO/ASTM 52701:2013 | Guide for performance characterization of dosimeters and dosimetry systems for use in radiation processing |
ISO 14470:2011 | Food irradiation — Requirements for the development, validation and routine control of the process of irradiation using ionizing radiation for the treatment of food |
ISO 10012:2003 | Measurement management systems — Requirements for measurement processes and measuring equipment |
ISO/ASTM 51707:2015 | Guide for estimation of measurement uncertainty in dosimetry for radiation processing |
ISO/ASTM 52628:2013 | Standard practice for dosimetry in radiation processing |
ASTM E 2303 : 2015 : REDLINE | Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.