13/30280627 DC : 0
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
BS ISO 7240-15 - FIRE DETECTION AND ALARM SYSTEMS - PART 15: POINT-TYPE FIRE DETECTORS USING SMOKE AND HEAT SENSORS
Hardcopy , PDF
31-07-2014
English
Foreword
Introduction
1 Scope
2 References
3 Terms, definitions and abbreviations
4 Requirements
5 Tests
6 Test report
7 Marking
8 Data
Annex A (normative) - Compensation for
detector drift
Annex B (normative) - Smoke tunnel for
smoke-response value measurements
Annex C (normative) - Heat tunnel for
heat-response value measurements
Annex D (normative) - Apparatus for the
dazzling test
Annex E (normative) - Apparatus for the
impact test
Annex F (normative) - Fire test room
Annex G (normative) - Open cellulosic (wood)
fire (TF1)
Annex H (normative) - Smouldering (pyrolysis)
wood fire (TF2)
Annex I (normative) - Glowing smouldering
cotton fire (TF3)
Annex J (normative) - Flaming plastics
(polyurethane) fire (TF4)
Annex K (normative) - Flaming liquid
(n-heptane) fire (TF5)
Annex L (normative) - Low-temperature black-smoke
liquid (decalin) fire (TF8)
Annex M (informative) - Construction of the measuring
ionization chamber
Annex N (informative) - Construction of the heat tunnel
BS ISO 7240-15.
Committee |
FSH/12
|
DocumentType |
Draft
|
Pages |
77
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
ISO 209:2007 | Aluminium and aluminium alloys — Chemical composition |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
ISO 7240-5:2012 | Fire detection and alarm systems Part 5: Point-type heat detectors |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
ISO 7240-1:2014 | Fire detection and alarm systems — Part 1: General and definitions |
ISO 7240-7:2011 | Fire detection and alarm systems Part 7: Point-type smoke detectors using scattered light, transmitted light or ionization |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |