12/30260278 DC : 0

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

BS 5839-1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE

Available format(s)

Hardcopy , PDF

Superseded date

31-03-2013

Superseded by

BS 5839-1:2013

Language(s)

English

$102.32
Including GST where applicable

Foreword
Section 1: General
1 Scope
2 Normative references
3 Terms and definitions
4 Need for a fire detection and fire alarm
   system and type of system
5 Categories of system
6 Exchange of information and definition of
   responsibilities
7 Variations from the recommendations of this
   standard
Section 2: Design considerations
8 Relationship between system Category and
   areas protected
9 Actuation of other fire protection systems or
   safety facilities
10 Systems in explosive gas or dust atmospheres
11 System components
12 Monitoring, integrity and reliability of circuits
   external to control equipment
13 Detection zones
14 Alarm zones
15 Communication with the fire and rescue service
16 Audible alarm signals
17 Visual alarm signals
18 Fire alarm warnings for people with impaired
   hearing
19 Staged fire alarms
20 Manual call points
21 Types of fire detector and their selection
22 Spacing and sitting of automatic fire detectors
23 Control and indicating equipment
24 Networked systems
25 Power supplies
26 Cables, wiring and other interconnections
27 Radio-linked systems
28 Electromagnetic compatibility
29 Electrical safety
Section 3: Limitation of false alarms
30 Responsibility for limitation of false alarms
31 Categories of false alarms
32 Acceptable rate of false alarms
33 Causes of false alarms
34 Design process for limitation of false alarms
35 Measures to limit false alarms
Section 4: Installation
36 Responsibility of installer
37 Installation practices and workmanship
38 Inspection and testing of wiring
Section 5: Commissioning and handover
39 Commissioning
40 Documentation
41 Certification
42 Acceptance
43 Verification
Section 6: Maintenance
44 Routine testing
45 Inspection and servicing
46 Non-routine attention
Section 7: Users responsibilities
47 Premises management
48 Log book
Annexes
Annex A (informative) - Choice of appropriate category
        of fire detection and fire alarm system
Annex B (informative) - Typical noise levels in buildings
Annex C (normative) - Control and transmission equipment
        for tactile alarm devices provided for
        people with impaired hearing systems
Annex D (normative) - Method for calculating standby
        battery capacity
Annex E (informative) - Schematic for design against
        false alarms
Annex F (informative) - Model format for system log
        book
Annex G (informative) - Model certificates
Bibliography

BS 5839-1

Committee
FSH/12/1
DocumentType
Draft
Pages
155
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

BS EN 54-23:2010 Fire detection and fire alarm systems Fire alarm devices. Visual alarm devices
BS 4678-4:1982 Cable trunking Specification for cable trunking made of insulating material
DD CLC/TS 50398:2009 Alarm systems. Combined and integrated systems. General requirements
IEC 60702-1:2002+AMD1:2015 CSV Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables
BS EN 50131-1 : 2006 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
BS ISO 7240-15:2014 Fire detection and alarm systems Point-type fire detectors using smoke and heat sensors
BS EN 61672-1:2013 Electroacoustics. Sound level meters Specifications
BS EN 54-7:2001 Fire detection and fire alarm systems Smoke detectors. Point detectors using scattered light, transmitted light or ionization
BS EN 50200:2015 Method of test for resistance to fire of unprotected small cables for use in emergency circuits
BS EN ISO 13943:2017 Fire safety. Vocabulary
2004/108/EC : 2004 DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC
BS 5839-9:2011 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems
BS EN 60702-2 : 2002 MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 2: TERMINATIONS
BS EN 54-4:1998 Fire detection and fire alarm systems Power supply equipment
BS EN 54-2 : 1998 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
BS EN 54-3:2014 Fire detection and fire alarm systems Fire alarm devices. Sounders
BS EN 54-5 : 2017 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 5: HEAT DETECTORS - POINT HEAT DETECTORS
BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
BS 8434-2(2003) : 2003 METHODS OF TEST FOR ASSESSMENT OF THE FIRE INTEGRITY OF ELECTRIC CABLES - PART 2: TEST FOR UNPROTECTED SMALL CABLES FOR USE IN EMERGENCY CIRCUITS - BS EN 50200 WITH A 930 DEGREE C FLAME AND WITH WATER SPRAY
BS EN 54-12:2015 Fire detection and fire alarm systems Smoke detectors. Line detectors using an optical beam
PD 7974-4:2003 Application of fire safety engineering principles to the design of buildings Detection of fire and activation of fire protection systems. (Sub-system 4)
BS 8434-1:2003 Methods of test for assessment of the fire integrity of electric cables Test for unprotected small cables for use in emergency circuits. BS EN 50200 with addition of water spray
BS EN 54-10:2002 Fire detection and fire alarm systems Flame detectors. Point detectors
BS EN 50281-1-2:1999 Electrical apparatus for use in the presence of combustible dust. Electrical apparatus protected by enclosures Selection, installation and maintenance
BS 7974:2001 Application of fire safety engineering principles to the design of buildings. Code of practice
BS EN 60702-1 : 2002 MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES
BS ISO 7240-8:2014 Fire detection and alarm systems Point-type fire detectors using a carbon monoxide sensor in combination with a heat sensor
BS EN 54-25:2008 Fire detection and fire alarm systems Components using radio links
BS EN 54-20:2006 Fire detection and fire alarm systems Aspirating smoke detectors
BS EN 54-11:2001 Fire detection and fire alarm systems Manual call points
IEC 60702-2:2002+AMD1:2015 CSV Mineral insulated cables and their terminations with a rated voltagenot exceeding 750 V - Part 2: Terminations

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.