08/30149503 DC : DRAFT JAN 2008
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
BS EN ISO 14161 - STERILIZATION OF HEALTH CAR PRODUCTS - BIOLOGICAL INDICATORS - GUIDANCE FOR THE SELECTION, USE AND INTERPRETATION OF RESULTS
31-01-2010
23-11-2012
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Characteristics of biological indicators
5.1 General
5.2 Test organism suspension for direct inoculation
of products
5.3 Inoculated carriers
5.4 Self-contained biological indicators
5.5 Other biological indicators
6 Selection of supplier
6.1 General
6.2 Documentation
6.2.1 General
6.2.2 Manufacturer audit
7 Biological indicators in process development
7.1 General
7.2 Overkill approach
7.3 Combined biological indicator and bioburden method
7.4 Bioburden method
8 Biological indicators in sterilization validation
8.1 General
8.2 Placement and handling of biological indicators
8.3 Sterilizer qualification
8.4 Performance qualification
8.5 Review and approval of validation
8.6 Requalification
9 Biological indicators in routine monitoring
9.1 General
9.2 Placement and handling of biological indicators
9.3 Process challenge device (PCD)
10 Results
10.1 General
10.2 Interpretation of results
11 Application of biological indicator standards
11.1 General assessment of biological indicator
performance by the user
11.2 Nominal population of test organism
11.3 Resistance determination
11.3.1 General
11.3.2 Survivor curve method
11.3.3 Fraction-negative method
11.4 z-value determination
11.4.1 General
11.4.2 Graphically plotting the z-value
11.4.3 Mathematically calculating the z-value
11.4.4 Correlation coefficient (r) for the z-value
11.5 F (T, Z) Equivalent sterilization value determination
11.6 Establishing spore-log-reduction (SLR)
11.7 Sterility assurance level (SAL) calculation
11.8 Testing equipment
12 Culture conditions
12.1 General
12.2 Incubation temperature
12.3 Incubation period
12.4 Choice of growth medium
13 Third-party requirements
13.1 General
13.2 Minimum requirements for replicates and total
number of biological indicators
13.3 Test equipment
14 Personnel train
15 Storage and handling
15 Storage and handling
16 Disposal of biological indicators
Annex A (informative) - Microbiological inactivation kinetics
and enumeration techniques
Annex B (informative) - Process challenge devices
B.1 General
B.2 Helices
B.3 Standard test packs
B.4 User's process challenge devices
B.5 Biological test packs
Annex C (informative) - Formulae for fraction negative methods
for D-value calculations
C.1 General
C.2 Materials
C.3 Methods
C.3.1 Holcomb-Spearman-Karber Procedure (HSKP)
C.3.2 Limited Holcomb-Spearman-Karber-Procedure (LHSKP)
C.3.3 The Stumbo-Murphy-Cochran-Procedure (SMCP)
Annex D (informative) - Examples of documentation for biological
indicators prepared by the user
D.1 General
D.1.1 Sources of microorganism
D.1.2 Documentation
D.2 Commercially available suspension
D.3 Suspension from a commercially available strain
D.4 Suspension from in-house isolates
D.5 Inoculated carriers
D.5.1 General
D.5.2 Documentation of fluid carrier materials
D.5.3 Documentation of solid carrier materials
D.5.4 Documentation of inoculated carriers used for
Annex E (informative) - Calculation of z-value
Annex F (informative) - D-value determination by survivor
curve method
F.1 General
F.2 Materials
F.3 Procedure
Bibliography
BS EN ISO 14161
Committee |
LBI/35
|
DocumentType |
Draft
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ISO 19011:2011 | Guidelines for auditing management systems |
ISO 11138-3:2017 | Sterilization of health care products — Biological indicators — Part 3: Biological indicators for moist heat sterilization processes |
EN 285:2015 | Sterilization - Steam sterilizers - Large sterilizers |
ISO 11737-2:2009 | Sterilization of medical devices Microbiological methods Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process |
ISO 11737-1:2006 | Sterilization of medical devices Microbiological methods Part 1: Determination of a population of microorganisms on products |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
ISO 14937:2009 | Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices |
AAMI TIR31 : 2008 | PROCESS CHALLENGE DEVICES/TEST PACKS FOR USE IN HEALTH CARE FACILITIES |
ISO 8402:1994 | Quality management and quality assurance — Vocabulary |
ISO 11138-2:2017 | Sterilization of health care products — Biological indicators — Part 2: Biological indicators for ethylene oxide sterilization processes |
ISO/IEC 17011:2004 | Conformity assessment General requirements for accreditation bodies accrediting conformity assessment bodies |
ISO 11135-1:2007 | Sterilization of health care products Ethylene oxide Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO 18472:2006 | Sterilization of health care products Biological and chemical indicators Test equipment |
ISO/TS 11139:2006 | Sterilization of health care products Vocabulary |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 11138-1:2017 | Sterilization of health care products — Biological indicators — Part 1: General requirements |
ISO 11138-4:2017 | Sterilization of health care products — Biological indicators — Part 4: Biological indicators for dry heat sterilization processes |
ISO 11138-5:2017 | Sterilization of health care products — Biological indicators — Part 5: Biological indicators for low-temperature steam and formaldehyde sterilization processes |
ISO 17665-1:2006 | Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.