VDI 4252 Blatt 2:2004-06
Current
The latest, up-to-date edition.
Measurement of airborne microorganisms and viruses in ambient air - Active sampling of bioaerosols - Separation of airborne mould on gelatine/polycarbonate filters
Hardcopy , PDF
German - English
06-01-2004
Preliminary note
1 Scope
2 Terms and definitions
3 Principle of method
4 Sampling device
5 Measurement procedure
6 Sampling efficiency and method limitations
7 Calibration and function control
8 Maintenance
9 Quality assurance
Annex A - Sampling protocol for active sampling
of moulds using gelatine/polycarbonate-filters
(example
Annex B - Comparative measurements of
sampling heads according to VDI 4252 Part 2
and VDI 2463 Part 8
Annex C - Sample exchange for method
Validation
Bibliography
Describes requirements for sampling of moulds in ambient air by means of filter methods.
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
Verlag des Vereins Deutscher Ingenieure
|
Status |
Current
|
Supersedes |
CEN/TS 16115-1:2011 | Ambient air quality - Measurement of bioaerosols - Part 1: Determination of moulds using filter sampling systems and culture-based analyses |
VDI 3475 Blatt 2:2005-12 | Emission control - Facilities for biological waste - Composting an anaerobic (co-)digestion - Plant capacities up to approx. 6000 Mg/a |
DIN ISO 12219-5:2014-10 | INTERIOR AIR OF ROAD VEHICLES - PART 5: SCREENING METHOD FOR THE DETERMINATION OF THE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS FROM VEHICLE INTERIOR PARTS AND MATERIALS - STATIC CHAMBER METHOD (ISO 12219-5:2014) |
DIN ISO 12219-4:2013-12 | INTERIOR AIR OF ROAD VEHICLES - PART 4: METHOD FOR THE DETERMINATION OF THE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS FROM VEHICLE INTERIOR PARTS AND MATERIALS - SMALL CHAMBER METHOD (ISO 12219-4:2013) |
BS ISO 16000-16:2008 | Indoor air Detection and enumeration of moulds. Sampling by filtration |
VDI 4250 Blatt 2:2015-11 | Bioaerosols and biological agents - Environmental health assessment of bioaerosols in ambient air - Risk assessment for aerosols containing Legionella |
DIN ISO 12219-6:2015-04 (Draft) | INTERIOR AIR OF ROAD VEHICLES - PART 6: METHOD FOR THE DETERMINATION OF THE EMISSIONS OF SEMI-VOLATILE ORGANIC COMPOUNDS FROM VEHICLE INTERIOR PARTS AND MATERIALS AT HIGHER TEMPERATURE - SMALL CHAMBER METHOD (ISO 12219-6:2017) |
DIN ISO 16000-20:2015-11 | INDOOR AIR - PART 20: DETECTION AND ENUMERATION OF MOULDS - DETERMINATION OF TOTAL SPORE COUNT (ISO 16000-20:2014) |
VDI 4251-1 : 2007 COR 2 2016 | MEASUREMENT OF AIRBORNE MICROORGANISMS AND VIRUSES IN AMBIENT AIR - PLANNING OF PLANT-RELATED AMBIENT AIR MEASUREMENTS - PLUME MEASUREMENT |
VDI 4255 Blatt 4:2017-03 | Bioaerosols and biological agents - Emission factors for pig husbandry |
DIN EN ISO 16000-32:2014-10 | INDOOR AIR - PART 32: INVESTIGATION OF BUILDINGS FOR THE OCCURRENCE OF POLLUTANTS (ISO 16000-32:2014) |
DIN EN ISO 16000-26:2012-11 | Indoor air - Part 26: Sampling strategy for carbon dioxide (CO<(Index)2>) (ISO 16000-26:2012); German version EN ISO 16000-26:2012 |
VDI 2083 Blatt 18:2012-01 | Cleanroom technology - Biocontamination control |
DIN ISO 16000-18:2012-01 | Indoor air - Part 18: Detection and enumeration of moulds - Sampling by impaction (ISO 16000-18:2011 + Cor.1:2011) |
BS ISO 16000-17:2008 | Indoor air Detection and enumeration of moulds. Culture-based method |
VDI 4253 Blatt 2:2004-06 | Measurement of airborne microorganisms and viruses in ambient air - Culture based method for the determination of the concentration of mould in air - Indirect method after sampling with gelatine/polycarbonate filters |
DIN EN ISO 16000-19:2014-12 | Indoor air - Part 19: Sampling strategy for moulds (ISO 16000-19:2012) |
VDI 4255 Blatt 2:2009-12 | Bioaerosols and biological agents - Emission sources and control measures in livestock operations - Overview |
DIN ISO 16000-17:2010-06 | Indoor air - Part 17: Detection and enumeration of moulds - Culture-based method (ISO 16000-17:2008) |
DIN ISO 12219-3:2013-12 | Interior air of road vehicles - Part 3: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials - Micro-scale chamber method (ISO 12219-3:2012) |
UNE-CEN/TS 16115-1:2013 | Ambient air quality - Measurement of bioaerosols - Part 1: Determination of moulds using filter sampling systems and culture-based analyses |
DIN ISO 16000-31:2014-09 | INDOOR AIR - PART 31: MEASUREMENT OF FLAME RETARDANTS AND PLASTICIZERS BASED ON ORGANOPHOSPHORUS COMPOUNDS - PHOSPHORIC ACID ESTER (ISO 16000-31:2014) |
DIN ISO 16000-29:2015-02 | INDOOR AIR - PART 29: TEST METHODS FOR VOC DETECTORS (ISO 16000-29:2014) |
VDI 2463 Blatt 7:2014-05 | Particulate matter measurement - Determination of suspended particulate matter and gaseous chemical compounds in ambient air and indoor air - Active sampling via low-volume sampler (LVS) |
VDI 4251 Blatt 3:2015-08 | Measurement of airborne microorganisms and viruses in ambient air - Plant-related dispersion modelling for bioaerosols |
DIN ISO 12219-2:2012-11 | Interior air of road vehicles - Part 2: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials - Bag method (ISO 12219-2:2012) |
DIN ISO 16000-33:2015-07 (Draft) | INDOOR AIR - PART 33: DETERMINATION OF PHTHALATES WITH GAS CHROMATOGRAPHY/MASS SPECTROMETRY (GC/MS) (ISO 16000-33:2017) |
DIN ISO 16000-33:2017-12 | INDOOR AIR - PART 33: DETERMINATION OF PHTHALATES WITH GAS CHROMATOGRAPHY/MASS SPECTROMETRY (GC/MS) (ISO 16000-33:2017) |
VDI 4253 Blatt 4:2013-02 | Bioaerosols and biological agents - Determination of total cell count by fluorescence analysis after staining with DAPI |
ISO 16000-17:2008 | Indoor air — Part 17: Detection and enumeration of moulds — Culture-based method |
VDI 4255-1 : 2005 COR 2016 | BIOAEROSOLS AND BIOLOGICAL AGENTS - SOURCES OF EMISSIONS AND CONTROL MEASURES - OVERVIEW |
VDI 4255 Blatt 3:2016-12 | Bioaerosols and biological agents - Emission factors for poultry |
DIN ISO 16000-27:2014-11 | INDOOR AIR - PART 27: DETERMINATION OF SETTLED FIBROUS DUST ON SURFACES BY SEM (SCANNING ELECTRON MICROSCOPY) (DIRECT METHOD) (ISO 16000-27:2014) |
DIN ISO 16000-24:2013-01 | INDOOR AIR - PART 24: PERFORMANCE TEST FOR EVALUATING THE REDUCTION OF VOLATILE ORGANIC COMPOUND (EXCEPT FORMALDEHYDE) CONCENTRATIONS BY SORPTIVE BUILDING MATERIALS (ISO 16000-24:2009) |
DIN ISO 12219-1:2013-12 | Interior air of road vehicles - Part 1: Whole vehicle test chamber - Specification and method for the determination of volatile organic compounds in cabin interiors (ISO 12219-1:2012) |
DIN ISO 16000-6:2012-11 | Indoor air - Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA? sorbent, thermal desorption and gas chromatography using MS or MS-FID (ISO 16000-6:2011) |
DIN ISO 16000-25:2012-01 | Indoor air - Part 25: Determination of the emission of semi-volatile organic compounds by building products - Micro-chamber method (ISO 16000-25:2011) |
DIN ISO 16000-28:2012-12 | Indoor air - Part 28: Determination of odour emissions from building products using test chambers (ISO 16000-28:2012) |
VDI 4251 Blatt 2:2015-08 | Measurement of airborne microorganisms and viruses in ambient air - Determination of area-specific background concentrations |
DIN ISO 16000-4:2012-11 | INDOOR AIR - PART 4: DETERMINATION OF FORMALDEHYDE - DIFFUSIVE SAMPLING METHOD (ISO 16000-4:2011) |
DD CEN/TS 16115-1:2011 | Ambient air quality. Measurement of bioaerosols Determination of moulds using filter sampling systems and culture-based analyses |
VDI 3787 Blatt 10:2010-03 | Environmental meteorology - Human biometeorological requirements in the framework of recreation, prevention, therapy, and rehabilitation |
DIN ISO 16000-3:2013-01 | Indoor air - Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air - Active sampling method (ISO 16000-3:2011) |
ISO 16000-16:2008 | Indoor air — Part 16: Detection and enumeration of moulds — Sampling by filtration |
VDI 3898:2013-01 | Emission control - Plants for dry mechanical, physio-chemical, thermal and biological soil treatment |
VDI 4251 Blatt 4:2017-01 | Measurement of airborne microorganisms and viruses in ambient air - Determination of existing load |
PD CEN/TS 16115-2:2016 | Ambient air. Measurement of bioaerosols Planning and evaluation of plant-related plume measurements |
VDI 4250 Blatt 1:2014-08 | Bioaerosols and biological agents - Risk assessment of source-related ambient air measurements in the scope of environmental health - Effects of bioaerosol pollution on human health |
VDI 3475 Blatt 5:2015-10 | Emission control - Biological waste treatment facilities - Anaerobic digestion and post-treatment |
DIN ISO 12219-7:2016-02 (Draft) | INTERIOR AIR OF ROAD VEHICLES - PART 7: ODOUR DETERMINATION IN INTERIOR AIR OF ROAD VEHICLES AND TEST CHAMBER AIR OF TRIM COMPONENTS BY OLFACTORY MEASUREMENTS (ISO 12219-7:2017) |
DIN ISO 16000-30:2015-05 | INDOOR AIR - PART 30: SENSORY TESTING OF INDOOR AIR (ISO 16000-30:2014) |
DIN ISO 16000-16:2009-12 | Indoor air - Part 16: Detection and enumeration of moulds - Sampling by filtration (ISO 16000-16:2008) |
DIN ISO 16000-14:2012-03 | Indoor air - Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) - Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry (ISO 16000-14:2009) |
VDI 3477:2016-03 | Biological waste gas purification - Biofilters |
CEN/TS 16115-2:2016 | Ambient air - Measurement of bioaerosols - Part 2: Planning and evaluation of plant-related plume measurements |
DIN ISO 16000-19:2012-12 | INDOOR AIR - PART 19: SAMPLING STRATEGY FOR MOULDS (ISO 16000-19:2012) |
S.R. CEN/TS 16115-2:2016 | AMBIENT AIR - MEASUREMENT OF BIOAEROSOLS - PART 2: PLANNING AND EVALUATION OF PLANT-RELATED PLUME MEASUREMENTS |
S.R. CEN TS 16115-1:2011 | AMBIENT AIR QUALITY - MEASUREMENT OF BIOAEROSOLS - PART 1: DETERMINATION OF MOULDS USING FILTER SAMPLING SYSTEMS AND CULTURE-BASED ANALYSES |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
DIN ISO 7708:1996-01 | AIR QUALITY - PARTICLE SIZE FRACTION DEFINITIONS FOR HEALTH-RELATED SAMPLING |
VDI 4253 Blatt 3:2008-08 | Measurement of airborne microorganisms and viruses in ambient air - Culture based method for the quantitative determination of bacteria in air - Method after separation in liquids |
EN 13098:2000 | Workplace atmosphere - Guidelines for measurement of airborne micro-organisms and endotoxin |
VDI 4253 Blatt 2:2004-06 | Measurement of airborne microorganisms and viruses in ambient air - Culture based method for the determination of the concentration of mould in air - Indirect method after sampling with gelatine/polycarbonate filters |
ISO/R 708:1968 | Withdrawal of ISO/R 708-1968 |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.