PREN 1856-2 : DRAFT 2008
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
CHIMNEYS - REQUIREMENTS FOR METAL CHIMNEYS - PART 2: METAL FLUE LINERS AND CONNECTING FLUE PIPES
06-01-2009
01-12-2013
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Manufacturer's declaration for type test
5 Dimensions and tolerances
6 Performance requirements
6.1 Mechanical resistance and stability
6.1.1 Rigid flue liners and rigid connecting
flue pipes and fittings
6.1.2 Flexible flue liners
6.2 Resistance to fire
6.2.1 Rigid flue liners and fittings
6.2.2 Rigid connecting flue pipes and fittings
6.2.3 Flexible flue liners and fittings
6.3 Gas tightness
6.4 Safety in use
6.4.1 Thermal performance at normal
operating conditions
6.4.2 Accidental human contact
6.4.3 Thermal resistance
6.4.4 Water vapour diffusion resistance
6.4.5 Condensate penetration resistance
6.4.6 Flow resistance
6.5 Durability
6.5.1 Durability against corrosion
6.5.2 Freeze thaw resistance
6.5.3 Flue liner seals
7 Product information
7.1 Manufacturer's instructions
7.2 Minimum information to be included in the
manufacturer's documentation and instructions
7.2.1 Rigid flue liners, rigid connecting flue
pipes and fittings
7.2.2 Flexible flue liners and fittings
8 Marking and labelling
8.1 Flue liners, rigid connecting flue pipes
and fittings
8.2 Chimney plate
8.3 Packaging
9 Product designation
10 Evaluation of conformity
10.1 General
10.2 Type testing
10.2.1 Initial type testing
10.2.2 Further type testing
10.2.3 Sampling for type testing
10.3 Factory production control (FPC)
10.3.1 General
10.3.2 Equipment
10.3.3 Raw materials and components
10.3.4 Product testing and evaluation
10.3.5 Non conforming products
Annex A (normative) - Test methods
A.1 Measure of diameter of flexible flue liner
A.1.1 Procedure
A.1.2 Results
A.2 Gas tightness
A.2.1 General
A.2.2 Conditioning and apparatus
A.2.3 Procedure
A.2.4 Results
A.3 Tensile strength
A.3.1 Test assembly
A.3.2 Procedure
A.3.3 Test results
A.4 Crushing resistance
A.4.1 Test apparatus
A.4.2 Procedure
A.4.3 Test results
A.5 Flexibility test
A.5.1 Test apparatus
A.5.2 Test conditioning
A.5.3 Procedure
A.5.4 Results
A.6 Torsion strength test
A.6.1 Test apparatus
A.6.2 Test assembly
A.6.3 Procedure
A.6.4 Results
A.7 Thermal performance test
A.7.1 Apparatus
A.7.2 Test structures
A.7.3 Test samples
A.7.4 Thermal test procedure
Annex B (normative) - Choice of size for type
test and sampling
B.1 General
B.2 Thermal testing
B.3 Mechanical tests
B.4 Gas tightness
B.5 Samples
B.6 Factory production control
B.7 Nature of changes requiring further type test
Annex ZA (informative) - Relationship between this
European Standard and the
Essential Requirements of
Construction Products
Directive (89/106/EEC)
ZA.1 Scope and relevant characteristics
ZA.2 Procedure(s) for attestation of conformity
of rigid or flexible flue liners and
rigid connecting flue pipes
ZA.2.1 System(s) of attestation of conformity
ZA.2.2 EC Declaration of conformity
ZA.3 CE marking and labelling
Bibliography
Describes the performance requirements for rigid or flexible metal flue liners, rigid metal connecting flue pipes and their fittings used to convey the products of combustion from appliances to the outside atmosphere (including their supports).
Committee |
TC 166
|
DocumentType |
Draft
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
Standards | Relationship |
96/103098 DC : DRAFT APRIL 1996 | Identical |
08/30185757 DC : 0 | Identical |
S.R. CR 12695:1997 | METAL CHIMNEYS - CORROSION RESISTANCE REQUIREMENTS AND TEST METHODS |
04/30122093 DC : 0 | EN 14989-2 - CHIMNEYS AND AIR SUPPLY DUCT SYSTEMS FOR ROOM SEALED APPLIANCES - REQUIREMENTS AND TEST METHODS - PART 2: FLUE AND AIR SUPPLY DUCTS FOR INDIVIDUAL ROOM SEALED APPLIANCES |
02/104192 DC : DRAFT JUN 2002 | EN 1856-1 - CHIMNEYS - REQUIREMENTS FOR METAL CHIMNEYS - PART 1: SYSTEM CHIMNEY PRODUCTS |
EN 12391-1:2003 | Chimneys - Execution standard for metal chimneys - Part 1: Chimneys for non-roomsealed heating appliances |
I.S. EN 12391-1:2004 | CHIMNEYS - EXECUTION STANDARD FOR METAL CHIMNEYS - PART 1: CHIMNEYS FOR NON-ROOMSEALED HEATING APPLIANCES |
I.S. EN 1443:2003 | CHIMNEYS - GENERAL REQUIREMENTS |
EN 1443:2003 | Chimneys - General requirements |
BS EN 1443:2003 | Chimneys. General requirements |
DIN EN 12391-1:2004-04 | CHIMNEYS - EXECUTION STANDARD FOR METAL CHIMNEYS - PART 1: CHIMNEYS FOR NON-ROOM SEALED HEATING APPLIANCES |
04/30115682 DC : DRAFT JUN 2004 | EN 14989-1 - CHIMNEYS AND AIR SUPPLY DUCT SYSTEMS FOR ROOMSEALED APPLIANCES - REQUIREMENTS AND TEST METHODS - PART 1: VERTICAL TERMINALS FOR C6-TYPE APPLIANCES |
CR 12695:1997 | Metal chimneys - Corrosion resistance requirements and test methods |
NFD 35 307 : 99 XP | FLEXIBLE METAL CHIMNEYS, SINGLE WALL, FOR LINERS AND CONNECTING FLUE PIPES |
BS EN 12391-1:2003 | Chimneys. Execution standard for metal chimneys Chimneys for non-roomsealed heating appliances |
04/30122798 DC : DRAFT SEP 2004 | EN 15035 - HEATING BOILERS - ROOM SEALED OPERATIONS FOR BOILERS FOR FUEL OIL |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.