• Shopping Cart
    There are no items in your cart

NBN EN 61284 : 1998

Current

Current

The latest, up-to-date edition.

BOVENGRONDSE LIJNEN - EISEN AAN KLEMMEN EN ARMATUREN EN BEPROEVING

Published date

01-12-2013

Sorry this product is not available in your region.

1 Scope
2 Normative references
3 Definitions
4 Requirements
4.1 General requirements
4.1.1 Design
4.1.2 Materials
4.1.3 Dimensions and tolerances
4.1.4 Protection against corrosion
4.1.5 Marking
4.1.6 Instructions for assembly
4.2 Requirements for specific fittings
4.2.1 Insulator set fittings and earth wire fittings
4.2.2 Suspension clamps
4.2.3 Fittings for jointing, terminating and repairing
        conductor and earth wire
4.2.4 Insulator protective fittings
5 Heat cycle tests
5.1 Purpose
5.2 Joints
5.2.1 General
5.2.2 Service temperature
5.2.3 Classification for test purposes
5.3 Test specimens
5.3.1 General
5.3.2 Multi-range connectors
5.3.3 Preparation
5.3.4 Data on test specimens
5.4 Test arrangements
5.4.1 Test conditions
5.4.2 Reference conductor
5.4.3 Potential points
5.4.4 Installation of test loop
5.4.5 Measurements
5.5 Heat cycle test procedure
5.5.1 General
5.5.2 Joints of class A
5.5.3 Joints of class B
6 Corona and radio interference voltage (RIV) tests
6.1 Purpose
6.2 Description of test methods
6.3 General
6.4 Test circuit and instruments
6.5 Corona and RIV test procedures
6.6 Acceptance criteria
6.7 Test report
6.8 Voltage method
6.8.1 Adjacent conductors in a three-phase system
6.8.2 Test set-up and dimensions
6.8.3 Critical variant
6.8.4 Distance from wall (reflection plane,) w
6.8.5 Minimum clearance from adjacent live components
6.8.6 Metallic wall
6.9 voltage gradient method
6.9.1 Conductor voltage on three-phase system
6.9.2 Test set-up and dimensions
6.9.3 Test method
Annexes
A Typical joint types
B Typical test circuit - Class A Joints
C Typical test circuit - Class B joints
D Diagrammatic representation of heat cycle test
        sequence
E Mathematical acceptance criterion
F Examples of normative documents recommended for
        fitting materials
G Potential points
H Test voltage calibration device
ZA Normative references to international publications
        with their corresponding European publications



Applies to fittings used for overhead lines of nominal voltage above 45 KV. May be applied to fittings for overhead lines of lower nominal voltage and to similar fittings for substations.

DocumentType
Standard
PublisherName
Belgian Standards
Status
Current

Standards Relationship
UNE-EN 61284:1999 Identical
DIN EN 61284 : 1998 Identical
BS EN 61284:1998 Identical
SN EN 61284 : 1997 Identical
NF EN 61284 : 2000 Identical
I.S. EN 61284:1995 Identical
EN 61284:1997 Identical

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.