• Shopping Cart
    There are no items in your cart

MIL-PRF-39016 Revision H:2017

Current

Current

The latest, up-to-date edition.

Relays, Electromagnetic, Established Reliability, General Specification for

Available format(s)

PDF

Published date

09-13-2017

US$20.00
Excluding Tax where applicable

1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5. PACKAGING
6. NOTES

Specifies the general requirements for electromagnetic, hermetically sealed relays for use in electronic and communication-type equipment.

DocumentType
Standard
Pages
52
PublisherName
US Military Specs/Standards/Handbooks
Status
Current
Supersedes

This specification covers the general requirements for electromagnetic, hermetically sealed relays for use in electronic and communication-type equipment (see 6.1). These relays are designed to operate over the full range from low level to power switching with contact ratings up to 5 amperes alternating current (ac) or direct current (dc). The failure rate level is established at a confidence level of 90 percent for qualification and 60 percent for maintenance of qualification based on 100,000 cycles at +125°C under the rated load conditions specified herein. CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. CAUTION: Pick-up, hold, and dropout voltages are for test purposes only and are not to be used as design criteria. For additional application and caution information, see 6.1.

MIL-R-39016-39 Revision G:2014 RELAYS, ELECTROMAGNETIC, HERMETICALLY SEALED, 4PDT, LOW-LEVEL TO 3 AMPERES (400 MILLIWATTS)
MIL-STD-1580 Revision B:2003 DESTRUCTIVE PHYSICAL ANALYSIS FOR ELECTRONIC, ELECTROMAGNETIC, AND ELECTROMECHANICAL PARTS
MIL-PRF-39016-14 Revision F:2016 Relays, Electromagnetic, Established Reliability, 4PDT, Low Level To 2 Amperes (0.150-Inch Terminal Spacing)
MIL-PRF-39016-20 Revision J:2004 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION
MIL STD 11991 : A GENERAL STANDARD FOR PARTS, MATERIALS, AND PROCESSES
DSCC 85138 : D RELAYS, ELECTROMAGNETIC, HIGH VIBRATION, DPDT, LOW LEVEL TO 1.0 AMPERE, WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND REVERSE POLARITY PROTECTION
MIL-PRF-39016-18 Revision H:2005 Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1 Ampere with Internal Diode for Coil Transient Suppression, Terminals 0.100-Inch Grid Pattern
MIL-DTL-15103 Revision G:2015 SALINITY INDICATING EQUIPMENT
MIL-PRF-39016-44 Revision E:2006 Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes, Terminals 0.200-Inch Grid Pattern (Sensitive, 100/125 Milliwatts, Coil Operate Power at 25 Degrees C)
MIL-PRF-39016-7 Revision G:2004 Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 1 Ampere
MIL-HDBK-1760 Revision A:2004 AIRCRAFT/STORE ELECTRICAL INTERCONNECTION SYSTEM
MIL-PRF-39016-27 Revision F:2005 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 0.5 AMPERE (LATCHING) WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION
MIL-PRF-39016-28 Revision F:2005 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 0.5 AMPERE (LATCHING) WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION
MIL-PRF-39016-45 Revision F:2018 Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes (Latching)
MIL-PRF-39016-30 Revision F:2005 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE (LATCHING) WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION
MIL-PRF-39016-37 Revision D:2014 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 2 AMPERES (0.150-INCH TERMINAL SPACING), WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION
MIL-PRF-39016-47 Revision C:2006 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 0.5 AMPERE (.100 D.I.P. TERMINAL SPACING) ONE-TENTH SIZE, SENSITIVE, BI-STABLE, (LATCHING)
DSCC 84173 : F RELAYS, ELECTROMAGNETIC, HIGH VIBRATION, DPDT, LOW LEVEL TO 1.0 AMPERE WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION
NASA MSFC STD 3012 : 2012 ELECTRICAL, ELECTRONIC, AND ELECTROMECHANICAL (EEE) PARTS MANAGEMENT AND CONTROL REQUIREMENTS FOR MSFC SPACE FLIGHT HARDWARE
MIL-PRF-39016-53 Revision C:2006 Relays, Electromagnetic, Established Reliability, Hermetically Sealed, 4PDT, Low Level to 2 Amperes (.150-Inch Terminal Spacing) with Internal Diode for Coil Transient Suppression
MIL-PRF-39016-25 Revision F:2005 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 1.0 AMPERE (SENSITIVE, 40 MILLIWATTS) WITH AN INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION
MIL-PRF-39016-24 Revision F:2005 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 1.0 AMPERE WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION
MIL-PRF-39016-8 Revision J:2016 Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 0.5 Ampere (Latching)
MIL-PRF-39016-22 Revision F:2016 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 2 AMPERES (0.200-INCH TERMINAL SPACING) COIL TRANSIENT SUPPRESSED
MIL-PRF-39016-11 Revision G:2004 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE (SENSITIVE, 60 MILLIWATTS, COIL OPERATE POWER AT 25 DEGREES C
MIL-PRF-39016-26 Revision F:2005 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 1.0 AMPERE (SENSITIVE 4O MILLIWATTS) WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION
MIL-PRF-39016-54 Revision D:2006 Relays, Electromagnetic, Established Reliability, Hermetically Sealed, 4PDT, Low Level to 2 Amperes (.150-Inch Terminal Spacing) with Internal Diode for Coil Transient Suppression and Reverse Polarity Protection
MIL-PRF-39016-41 Revision E:2005 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1 AMPERE, TERMINALS 0.100-INCH GRID PATTERN SENSITIVE, 60 MILLIWATTS, COIL OPERATE POWER AT 25 DEGREE C
MIL R 39016/40 : G RELAYS, ELECTROMAGNETIC, 4PDT, LOW LEVEL TO 2.0 AMPERES (0.100-INCH TERMINAL SPACING)
MIL-PRF-39016-21 Revision H:2013 Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere (Sensitive, 60 Milliwatts) with Internal Diodes for Coil Transient Suppression and Polarity Reversal Protection
MIL-PRF-39016-6 Revision L:2004 Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes (0.200-Inch Terminal Spacing)
MIL-PRF-39016-15 Revision M:2014 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION
MIL-PRF-39016-13 Revision K:2013 Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes (0.150-Inch Terminal Spacing)
MIL-PRF-39016-48 Revision D:2013 Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 0.5 Ampere (.100 D.I.P. Terminal Spacing) One-Tenth Size, Sensitive, Monostable
MIL-PRF-39016-36 Revision C:2006 Relays, Electromagnetic, Established Reliability, Hermetically Sealed, 4PDT, Low Level to 2 Amperes (.150-Inch Terminal Spacing), Latching, with Internal Diodes for Coil Transient Suppression and Reverse Polarity Protection
MIL R 5757/7 : G RELAYS, ELECTROMAGNETIC, HERMETICALLY SEALED, 4PDT, LOW LEVEL TO 2 AMPERES
MIL-PRF-39016-23 Revision F:2005 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 1.0 AMPERE WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION
MIL-PRF-39016-19 Revision H:2005 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1 AMPERE WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION, TERMINALS 0.100-INCH GRID PATTERN
DSCC 84172 : F RELAYS, ELECTROMAGNETIC, HIGH VIBRATION, DPDT, LOW LEVEL TO 1.0 AMPERE
MIL-PRF-39016-29 Revision H:2017 Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere (Latching) with Internal Diodes for Coil Transient Suppression
MIL-PRF-83726 Revision H:2017 Relays, Hybrid and Solid State, Time Delay, General Specification for
MIL-PRF-39016-12 Revision H:2016 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE (LATCHING)
MIL-PRF-39016-35 Revision E:2017 Relays, Electromagnetic, Established Reliability, Hermetically Sealed, 4 PDT Low Level to 2 Amperes (0.150-Inch Terminal Spacing), Latching, with Internal Diodes for Coil Transient Suppression
MIL-PRF-39016-42 Revision E:2006 Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere with Internal Diode for Coil Transient Suppression, Terminals .100-Inch Grid Pattern (Sensitive 60 Milliwatts, Coil Operate Power at 25 Degree C)
MIL-R-39016-34 Revision F:2006 Relays, Electromagnetic, DPDT, Low Level to 1.0 Ampere, (0.100-Inch Terminal Spacing) (No S/S Document)
MIL-PRF-39016-16 Revision G:2004 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE (SENSITIVE, 60 MILLIWATTS) WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION
MIL R 39016/32 : F RELAYS, ELECTROMAGNETIC, DPDT, LOW LEVEL TO 2 AMPERES (LATCHING)
MIL-PRF-39016-9 Revision K:2016 Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere
MIL-PRF-39016-17 Revision J:2017 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1 AMPERE TERMINALS 0.100-INCH GRID PATTERN
MIL-PRF-39016-43 Revision E:2005 Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere, with Internal Diodes for Coil Transient Suppression, and Polarity Reversal Protection Terminals 0.100-Inch Grid Pattern (Sensitive, 60 Milliwatts, Coil Operate Power at 25 Degrees C)
MIL R 5757/1 : K RELAYS, ELECTRICAL, HERMETICALLY SEALED, 6PDT, LOW LEVEL TO 2 AMPERES
MIL-PRF-39016-10 Revision G:2004 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 1.0 AMPERE (SENSITIVE, 40 MILLIWATTS, COIL OPERATE POWER AT 25 DEGREES C)

MIL-STD-202-212 Base Document:2015 Method 212, Acceleration
MIL-STD-202-211 Base Document:2015 METHOD 211, TERMINAL STRENGTH
MIL-STD-202-302 Base Document:2015 Method 302, Insulation Resistance
MIL-STD-883 Revision K:2016 TEST METHOD STANDARD - MICROCIRCUITS
MIL-STD-202-210 Base Document:2015 Method 210, Resistance to Soldering Heat
MIL-STD-1276 Revision H:2013 Leads for Electronic Component Parts
MIL-STD-202-303 Base Document:2015 Method 303, DC Resistance
MIL-STD-1686 Revision C:1995 ELECTROSTATIC DISCHARGE CONTROL PROGRAM FOR PROTECTION OF ELECTRICAL AND ELECTRONIC PARTS, ASSEMBLIES AND EQUIPMENT (EXCLUDING ELECTRICALLY INITIATED EXPLOSIVE DEVICES)
MIL-STD-202-101 Base Document:2015 Method 101, Salt Atmosphere (Corrosion)
MIL-STD-750 Revision F:2011 TEST METHODS FOR SEMICONDUCTOR DEVICES
MIL-STD-202-107 Base Document:2015 Method 107, Thermal Shock
MIL-STD-202-301 Base Document:2015 Method 301, Dielectric Withstanding Voltage
MIL-HDBK-338 Revision B:1998 ELECTRONIC RELIABILITY DESIGN HANDBOOK
IEEE 315 : 1975 GRAPHIC SYMBOLS FOR ELECTRICAL AND ELECTRONICS DIAGRAMS (INCLUDING REFERENCE DESIGNATION LETTERS)
MIL-STD-202-215 Base Document:2015 METHOD 215, RESISTANCE TO SOLVENTS
MIL-STD-790 Revision G:2011 ESTABLISHED RELIABILITY AND HIGH RELIABILITY QUALIFIED PRODUCTS LIST (QPL) SYSTEMS FOR ELECTRICAL, ELECTRONIC, AND FIBER OPTIC PARTS SPECIFICATIONS
MIL-HDBK-263 Revision B:1994 ELECTROSTATIC DISCHARGE CONTROL HANDBOOK FOR PROTECTION OF ELECTRICAL & ELECTRONIC PARTS, ASSEMBLIES & EQUIPMENT
MIL-STD-202-105 Base Document:2015 Method 105, Barometric Pressure (Reduced)
MIL-STD-202-208 Base Document:2015 Method 208, Solderability
MIL-STD-202 Revision H:2015 ELECTRONIC AND ELECTRICAL COMPONENT PARTS
MIL-STD-1285 Revision D:2004 MARKING OF ELECTRICAL AND ELECTRONIC PARTS
EIA 557 : 2006 STATISTICAL PROCESS CONTROL SYSTEMS
MIL-STD-202-214 Base Document:2015 Method 214, Random Vibration
MIL-STD-690 Revision D:2005 Failure Rate (FR) Sampling Plans and Procedures
MIL-STD-202-312 Base Document:2015 Method 312, Life, Intermediate Current Switching
MIL-STD-202-204 Base Document:2015 Method 204, Vibration, High Frequency
MIL-STD-202-112 Base Document:2015 METHOD 112, SEAL
MIL-STD-202-213 Base Document:2015 Method 213, Shock (Specified Pulse)
MIL-STD-202-307 Base Document:2015 Method 307, Contact Resistance

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.