MIL-PRF-39016 Revision H:2017
Current
The latest, up-to-date edition.
Relays, Electromagnetic, Established Reliability, General Specification for
09-13-2017
1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5. PACKAGING
6. NOTES
Specifies the general requirements for electromagnetic, hermetically sealed relays for use in electronic and communication-type equipment.
DocumentType |
Standard
|
Pages |
52
|
PublisherName |
US Military Specs/Standards/Handbooks
|
Status |
Current
|
Supersedes |
This specification covers the general requirements for electromagnetic, hermetically sealed relays for use in electronic and communication-type equipment (see 6.1). These relays are designed to operate over the full range from low level to power switching with contact ratings up to 5 amperes alternating current (ac) or direct current (dc). The failure rate level is established at a confidence level of 90 percent for qualification and 60 percent for maintenance of qualification based on 100,000 cycles at +125°C under the rated load conditions specified herein. CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. CAUTION: Pick-up, hold, and dropout voltages are for test purposes only and are not to be used as design criteria. For additional application and caution information, see 6.1.
MIL-R-39016-39 Revision G:2014 | RELAYS, ELECTROMAGNETIC, HERMETICALLY SEALED, 4PDT, LOW-LEVEL TO 3 AMPERES (400 MILLIWATTS) |
MIL-STD-1580 Revision B:2003 | DESTRUCTIVE PHYSICAL ANALYSIS FOR ELECTRONIC, ELECTROMAGNETIC, AND ELECTROMECHANICAL PARTS |
MIL-PRF-39016-14 Revision F:2016 | Relays, Electromagnetic, Established Reliability, 4PDT, Low Level To 2 Amperes (0.150-Inch Terminal Spacing) |
MIL-PRF-39016-20 Revision J:2004 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION |
MIL STD 11991 : A | GENERAL STANDARD FOR PARTS, MATERIALS, AND PROCESSES |
DSCC 85138 : D | RELAYS, ELECTROMAGNETIC, HIGH VIBRATION, DPDT, LOW LEVEL TO 1.0 AMPERE, WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND REVERSE POLARITY PROTECTION |
MIL-PRF-39016-18 Revision H:2005 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1 Ampere with Internal Diode for Coil Transient Suppression, Terminals 0.100-Inch Grid Pattern |
MIL-DTL-15103 Revision G:2015 | SALINITY INDICATING EQUIPMENT |
MIL-PRF-39016-44 Revision E:2006 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes, Terminals 0.200-Inch Grid Pattern (Sensitive, 100/125 Milliwatts, Coil Operate Power at 25 Degrees C) |
MIL-PRF-39016-7 Revision G:2004 | Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 1 Ampere |
MIL-HDBK-1760 Revision A:2004 | AIRCRAFT/STORE ELECTRICAL INTERCONNECTION SYSTEM |
MIL-PRF-39016-27 Revision F:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 0.5 AMPERE (LATCHING) WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION |
MIL-PRF-39016-28 Revision F:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 0.5 AMPERE (LATCHING) WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION |
MIL-PRF-39016-45 Revision F:2018 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes (Latching) |
MIL-PRF-39016-30 Revision F:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE (LATCHING) WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION |
MIL-PRF-39016-37 Revision D:2014 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 2 AMPERES (0.150-INCH TERMINAL SPACING), WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION |
MIL-PRF-39016-47 Revision C:2006 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 0.5 AMPERE (.100 D.I.P. TERMINAL SPACING) ONE-TENTH SIZE, SENSITIVE, BI-STABLE, (LATCHING) |
DSCC 84173 : F | RELAYS, ELECTROMAGNETIC, HIGH VIBRATION, DPDT, LOW LEVEL TO 1.0 AMPERE WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION |
NASA MSFC STD 3012 : 2012 | ELECTRICAL, ELECTRONIC, AND ELECTROMECHANICAL (EEE) PARTS MANAGEMENT AND CONTROL REQUIREMENTS FOR MSFC SPACE FLIGHT HARDWARE |
MIL-PRF-39016-53 Revision C:2006 | Relays, Electromagnetic, Established Reliability, Hermetically Sealed, 4PDT, Low Level to 2 Amperes (.150-Inch Terminal Spacing) with Internal Diode for Coil Transient Suppression |
MIL-PRF-39016-25 Revision F:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 1.0 AMPERE (SENSITIVE, 40 MILLIWATTS) WITH AN INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION |
MIL-PRF-39016-24 Revision F:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 1.0 AMPERE WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION |
MIL-PRF-39016-8 Revision J:2016 | Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 0.5 Ampere (Latching) |
MIL-PRF-39016-22 Revision F:2016 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 2 AMPERES (0.200-INCH TERMINAL SPACING) COIL TRANSIENT SUPPRESSED |
MIL-PRF-39016-11 Revision G:2004 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE (SENSITIVE, 60 MILLIWATTS, COIL OPERATE POWER AT 25 DEGREES C |
MIL-PRF-39016-26 Revision F:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 1.0 AMPERE (SENSITIVE 4O MILLIWATTS) WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION |
MIL-PRF-39016-54 Revision D:2006 | Relays, Electromagnetic, Established Reliability, Hermetically Sealed, 4PDT, Low Level to 2 Amperes (.150-Inch Terminal Spacing) with Internal Diode for Coil Transient Suppression and Reverse Polarity Protection |
MIL-PRF-39016-41 Revision E:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1 AMPERE, TERMINALS 0.100-INCH GRID PATTERN SENSITIVE, 60 MILLIWATTS, COIL OPERATE POWER AT 25 DEGREE C |
MIL R 39016/40 : G | RELAYS, ELECTROMAGNETIC, 4PDT, LOW LEVEL TO 2.0 AMPERES (0.100-INCH TERMINAL SPACING) |
MIL-PRF-39016-21 Revision H:2013 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere (Sensitive, 60 Milliwatts) with Internal Diodes for Coil Transient Suppression and Polarity Reversal Protection |
MIL-PRF-39016-6 Revision L:2004 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes (0.200-Inch Terminal Spacing) |
MIL-PRF-39016-15 Revision M:2014 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION |
MIL-PRF-39016-13 Revision K:2013 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes (0.150-Inch Terminal Spacing) |
MIL-PRF-39016-48 Revision D:2013 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 0.5 Ampere (.100 D.I.P. Terminal Spacing) One-Tenth Size, Sensitive, Monostable |
MIL-PRF-39016-36 Revision C:2006 | Relays, Electromagnetic, Established Reliability, Hermetically Sealed, 4PDT, Low Level to 2 Amperes (.150-Inch Terminal Spacing), Latching, with Internal Diodes for Coil Transient Suppression and Reverse Polarity Protection |
MIL R 5757/7 : G | RELAYS, ELECTROMAGNETIC, HERMETICALLY SEALED, 4PDT, LOW LEVEL TO 2 AMPERES |
MIL-PRF-39016-23 Revision F:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 1.0 AMPERE WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION |
MIL-PRF-39016-19 Revision H:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1 AMPERE WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION, TERMINALS 0.100-INCH GRID PATTERN |
DSCC 84172 : F | RELAYS, ELECTROMAGNETIC, HIGH VIBRATION, DPDT, LOW LEVEL TO 1.0 AMPERE |
MIL-PRF-39016-29 Revision H:2017 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere (Latching) with Internal Diodes for Coil Transient Suppression |
MIL-PRF-83726 Revision H:2017 | Relays, Hybrid and Solid State, Time Delay, General Specification for |
MIL-PRF-39016-12 Revision H:2016 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE (LATCHING) |
MIL-PRF-39016-35 Revision E:2017 | Relays, Electromagnetic, Established Reliability, Hermetically Sealed, 4 PDT Low Level to 2 Amperes (0.150-Inch Terminal Spacing), Latching, with Internal Diodes for Coil Transient Suppression |
MIL-PRF-39016-42 Revision E:2006 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere with Internal Diode for Coil Transient Suppression, Terminals .100-Inch Grid Pattern (Sensitive 60 Milliwatts, Coil Operate Power at 25 Degree C) |
MIL-R-39016-34 Revision F:2006 | Relays, Electromagnetic, DPDT, Low Level to 1.0 Ampere, (0.100-Inch Terminal Spacing) (No S/S Document) |
MIL-PRF-39016-16 Revision G:2004 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE (SENSITIVE, 60 MILLIWATTS) WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION |
MIL R 39016/32 : F | RELAYS, ELECTROMAGNETIC, DPDT, LOW LEVEL TO 2 AMPERES (LATCHING) |
MIL-PRF-39016-9 Revision K:2016 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere |
MIL-PRF-39016-17 Revision J:2017 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1 AMPERE TERMINALS 0.100-INCH GRID PATTERN |
MIL-PRF-39016-43 Revision E:2005 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere, with Internal Diodes for Coil Transient Suppression, and Polarity Reversal Protection Terminals 0.100-Inch Grid Pattern (Sensitive, 60 Milliwatts, Coil Operate Power at 25 Degrees C) |
MIL R 5757/1 : K | RELAYS, ELECTRICAL, HERMETICALLY SEALED, 6PDT, LOW LEVEL TO 2 AMPERES |
MIL-PRF-39016-10 Revision G:2004 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 1.0 AMPERE (SENSITIVE, 40 MILLIWATTS, COIL OPERATE POWER AT 25 DEGREES C) |
MIL-STD-202-212 Base Document:2015 | Method 212, Acceleration |
MIL-STD-202-211 Base Document:2015 | METHOD 211, TERMINAL STRENGTH |
MIL-STD-202-302 Base Document:2015 | Method 302, Insulation Resistance |
MIL-STD-883 Revision K:2016 | TEST METHOD STANDARD - MICROCIRCUITS |
MIL-STD-202-210 Base Document:2015 | Method 210, Resistance to Soldering Heat |
MIL-STD-1276 Revision H:2013 | Leads for Electronic Component Parts |
MIL-STD-202-303 Base Document:2015 | Method 303, DC Resistance |
MIL-STD-1686 Revision C:1995 | ELECTROSTATIC DISCHARGE CONTROL PROGRAM FOR PROTECTION OF ELECTRICAL AND ELECTRONIC PARTS, ASSEMBLIES AND EQUIPMENT (EXCLUDING ELECTRICALLY INITIATED EXPLOSIVE DEVICES) |
MIL-STD-202-101 Base Document:2015 | Method 101, Salt Atmosphere (Corrosion) |
MIL-STD-750 Revision F:2011 | TEST METHODS FOR SEMICONDUCTOR DEVICES |
MIL-STD-202-107 Base Document:2015 | Method 107, Thermal Shock |
MIL-STD-202-301 Base Document:2015 | Method 301, Dielectric Withstanding Voltage |
MIL-HDBK-338 Revision B:1998 | ELECTRONIC RELIABILITY DESIGN HANDBOOK |
IEEE 315 : 1975 | GRAPHIC SYMBOLS FOR ELECTRICAL AND ELECTRONICS DIAGRAMS (INCLUDING REFERENCE DESIGNATION LETTERS) |
MIL-STD-202-215 Base Document:2015 | METHOD 215, RESISTANCE TO SOLVENTS |
MIL-STD-790 Revision G:2011 | ESTABLISHED RELIABILITY AND HIGH RELIABILITY QUALIFIED PRODUCTS LIST (QPL) SYSTEMS FOR ELECTRICAL, ELECTRONIC, AND FIBER OPTIC PARTS SPECIFICATIONS |
MIL-HDBK-263 Revision B:1994 | ELECTROSTATIC DISCHARGE CONTROL HANDBOOK FOR PROTECTION OF ELECTRICAL & ELECTRONIC PARTS, ASSEMBLIES & EQUIPMENT |
MIL-STD-202-105 Base Document:2015 | Method 105, Barometric Pressure (Reduced) |
MIL-STD-202-208 Base Document:2015 | Method 208, Solderability |
MIL-STD-202 Revision H:2015 | ELECTRONIC AND ELECTRICAL COMPONENT PARTS |
MIL-STD-1285 Revision D:2004 | MARKING OF ELECTRICAL AND ELECTRONIC PARTS |
EIA 557 : 2006 | STATISTICAL PROCESS CONTROL SYSTEMS |
MIL-STD-202-214 Base Document:2015 | Method 214, Random Vibration |
MIL-STD-690 Revision D:2005 | Failure Rate (FR) Sampling Plans and Procedures |
MIL-STD-202-312 Base Document:2015 | Method 312, Life, Intermediate Current Switching |
MIL-STD-202-204 Base Document:2015 | Method 204, Vibration, High Frequency |
MIL-STD-202-112 Base Document:2015 | METHOD 112, SEAL |
MIL-STD-202-213 Base Document:2015 | Method 213, Shock (Specified Pulse) |
MIL-STD-202-307 Base Document:2015 | Method 307, Contact Resistance |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.