1 Overview
1.1 Scope
1.2 Purpose
2 References
3 Definitions
4 Service conditions
4.1 Usual service conditions
4.2 Unusual service conditions
5 Rating
5.1 Rated maximum line-to-ground voltage
5.2 Rated frequency
5.3 Rated dielectric strength
5.4 Rated continuous current
6 General requirements
6.1 Electrical requirements
6.2 Physical requirements
6.3 Thermal requirements
6.4 Nameplate markings
7 Test procedure
7.1 Test conditions
7.2 Design tests
7.3 Special tests
7.4 Routine tests
Expand scope of standard to include indoor apparatus bushings (title modified as shown above). Update technical content as required to keep standard current.
DevelopmentNote |
Supersedes and Redesignates IEEE 21 (09/2004) Supersedes IEEE DRAFT C57.19.00. (06/2005)
|
DocumentType |
Standard
|
ISBN |
978-0-7381-4656-0
|
Pages |
27
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Withdrawn
|
Supersedes |
IEEE C57.12.10-2010 REDLINE | IEEE Standard Requirements for Liquid-Immersed Power Transformers |
IEEE C57.12.10-2010 | TRANSFORMERS - 230 KV AND BELOW 833/958 THROUGH 8333/10 417 KVA, SINGLE-PHASE, AND 750/862 THROUGH 60 000/80 000/100 000 KVA, THREE-PHASE WITHOUT LOAD TAP CHANGING; AND 3750/4687 THROUGH 60 000/80 000/100 000 KVA WITH LOAD TAP CHANGING - SAFETY REQUIREMENT |
CEI 14-43 : 2011 | GUIDE FOR THE APPLICATION, SPECIFICATION, AND TESTING OF PHASE-SHIFTING TRANSFORMERS |
IEEE DRAFT C57.19.01 : D7 MAY 99 | DRAFT STANDARD PERFORMANCE CHARACTERISTICS AND DIMENSIONS FOR OUTDOOR POWER APPARATUS BUSHINGS |
IEEE C57.152-2013 | IEEE Guide for Diagnostic Field Testing of Fluid-Filled Power Transformers, Regulators, and Reactors |
BS IEC/IEEE 65700-19-03 : 2014 | BUSHINGS FOR DC APPLICATION |
CSA C88.1 : 1996 : R2015 | POWER TRANSFORMERS AND REACTOR BUSHINGS |
IEEE C57.154-2012 | IEEE Standard for the Design, Testing, and Application of Liquid-Immersed Distribution, Power, and Regulating Transformers Using High-Temperature Insulation Systems and Operating at Elevated Temperatures |
IEEE C57.32-2015 | IEEE Standard for Requirements, Terminology, and Test Procedures for Neutral Grounding Devices |
IEEE DRAFT C57.12.36 : D10 2006 | REQUIREMENTS FOR LIQUID-IMMERSED DISTRIBUTION SUBSTATION TRANSFORMERS |
IEEE 693-2005 | IEEE Recommended Practice for Seismic Design of Substations |
IEEE DRAFT 62 : 200D8 | GUIDE FOR DIAGNOSTIC FIELD TESTING OF ELECTRIC POWER APPARATUS |
MIL-DTL-917 Revision F:2014 | ELECTRIC POWER EQUIPMENT, BASIC REQUIREMENTS FOR |
16/30336914 DC : 0 | BS EN 60076-57-129 ED 1.0 - CONVERTOR TRANSFORMERS - PART 57-129: TRANSFORMERS FOR HVDC APPLICATIONS |
IEEE C57.19.01-2000 | IEEE Standard Performance Characteristics and Dimensions for Outdoor Apparatus Bushings |
IEC/IEEE 65700-19-03:2014 | Bushings for DC application |
NEMA SG 4:2009(R2013) | ALTERNATING CURRENT HIGH-VOLTAGE CIRCUIT BREAKERS |
NEMA TR1 : 2013 | TRANSFORMERS, STEP VOLTAGE REGULATORS AND REACTORS |
IEEE C57.15-2009 REDLINE | IEEE Standard Requirements, Terminology, and Test Code for Step-Voltage Regulators |
IEEE C37.04-1999 | IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers |
17/30331680 DC : 0 | BS ISO 18095 - CONDITION MONITORING AND DIAGNOSTICS OF POWER TRANSFORMERS |
IEEE DRAFT C37.09 : D03F JAN 99 | TEST PROCEDURE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS |
IEEE 1861-2014 | IEEE Guide for On-Site Acceptance Tests of Electrical Equipment and System Commissioning of 1000 kV AC and Above |
CSA C88.1 : 1996 : R2005 | POWER TRANSFORMERS AND REACTOR BUSHINGS |
IEC/IEEE 60076-57-129:2017 | Power transformers - Part 57-129: Transformers for HVDC applications |
BS IEC 60076-21:2011 | Power transformers Standard requirements, terminology, and test code for step-voltage regulators |
IEEE C57.12.36-2007 | IEEE Standard Requirements for Liquid-Immersed Distribution Substation Transformers |
IEC 60076-21:2011 | Power transformers - Part 21: Standard requirements, terminology, and test code for step-voltage regulators |
IEC 62032:2012 | Guide for the Application, Specification and Testing of Phase-Shifting Transformers |
IEEE 62-1995 | IEEE Guide for Diagnostic Field Testing of Electric Power Apparatus - Part 1: Oil Filled Power Transformers, Regulators, and Reactors |
ISO 18095:2018 | Condition monitoring and diagnostics of power transformers |
IEEE C57.19.04-2018 | IEEE Standard for Performance Characteristics and Dimensions for High Current Power Transformer Bushings with Rated Continuous Current in Excess of 5000 A in Bus Enclosures |
IEEE DRAFT C57.12.90 : D5.1 98 | DRAFT STANDARD TEST CODE FOR LIQUID-IMMERSED DISTRIBUTION, POWER, AND REGULATING TRANSFORMERS |
IEEE C57.21 : 2008 | REQUIREMENTS, TERMINOLOGY, AND TEST CODE FOR SHUNT REACTORS RATED OVER 500 KVA |
IEEE C57.12.00-2015 | IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers |
EN IEC/IEEE 65700 : 2018 | BUSHINGS FOR DC APPLICATION (IEC/IEEE 65700-19-03:2014) |
IEEE C57.19.100-2012 REDLINE | IEEE Guide for Application of Power Apparatus Bushings |
CSA C88.1 : 1996 : R2011 | POWER TRANSFORMERS AND REACTOR BUSHINGS |
IEEE C57.129-2007 REDLINE | IEEE Standard for General Requirements and Test Code for Oil-Immersed HVDC Converter Transformers |
IEEE C57.135-2011 | IEEE Guide for the Application, Specification, and Testing of Phase-Shifting Transformers |
IEEE 18-2012 | IEEE Standard for Shunt Power Capacitors |
IEEE C57.19.0:2005 | STANDARD REQUIREMENTS, TERMINOLOGY, AND TEST CODE FOR BUSHINGS FOR DC APPLICATIONS |
IEEE C57.125-2015 | IEEE Guide for Failure Investigation, Documentation, Analysis, and Reporting for Power Transformers and Shunt Reactors |
IEEE DRAFT 18 : D7 99 | DRAFT STANDARD FOR SHUNT POWER CAPACITORS |
IEEE C37.09-1999 | IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
I.S. EN IEC/IEEE 65700:2018 | BUSHINGS FOR DC APPLICATION |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEEE C57.19.100-2012 REDLINE | IEEE Guide for Application of Power Apparatus Bushings |
NEMA 107:2016 | Methods of Measurement of Radio Influence Voltage (RIV) of High Voltage Apparatus |
IEEE C57.19.01-2000 | IEEE Standard Performance Characteristics and Dimensions for Outdoor Apparatus Bushings |
IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
IEC 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
IEEE C63.2-2009 | American National Standard for Electromagnetic Noise and Field Strength Instrumentation, 10 Hz to 40 GHz Specifications |
IEEE 693-2005 | IEEE Recommended Practice for Seismic Design of Substations |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.