• Shopping Cart
    There are no items in your cart

IEC 61217:2011

Current

Current

The latest, up-to-date edition.

Radiotherapy equipment - Coordinates, movements and scales

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French

Published date

12-07-2011

US$400.00
Excluding Tax where applicable

FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Coordinate systems
4 Identification of scales and digital DISPLAYS
5 Designation of ME EQUIPMENT movements
6 ME EQUIPMENT zero positions
7 List of scales, graduations, directions and DISPLAYS
Annex A (informative) - Examples of coordinate
        transformations between individual coordinate
        systems
Annex B (informative) - Coordinate transformations between
        IEC and DICOM PATIENT coordinates
Bibliography
Index of defined terms

IEC 61217:2011 applies to equipment and data related to the process of teleradiotherapy, including patient image data used in relation with radiotherapy treatment planning systems, radiotherapy simulators, isocentric gamma beam therapy equipment, isocentric medical electron accelerators, and non-isocentric equipment when relevant. The object of this standard is to define a consistent set of coordinate systems for use throughout the process of teleradiotherapy, to define the marking of scales (where provided), to define the movements of equipment used in this process, and to facilitate computer control when used. This second edition cancels and replaces the first edition, published in 1996, amendment 1, published in 2000 and amendment 2, published in 2007. This edition constitutes a technical revision to include imager and focus coordinate systems in Subclause 3.12. Beyond this Subclause, changes were only introduced where needed to include the above coordinate systems.

Committee
TC 62/SC 62C
DevelopmentNote
Stability Date: 2020. (11/2017)
DocumentType
Standard
Pages
134
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

Standards Relationship
GOST R IEC 61217 : 2013 Identical
NBN EN 61217 : 2012 Identical
NEN EN IEC 61217 : 2012 Identical
PN EN 61217 : 2012 Identical
UNE-EN 61217:2012 Identical
UNE-EN 61217:1999 Identical
CEI EN 61217 : 2012 Identical
EN 61217:2012 Identical
DIN EN 61217:2015-11 Identical
AS/NZS IEC 61217:2022 Identical
PNE-FprEN 61217 Identical
BS EN 61217:2012 Identical
GOST IEC 61217 : 2012 Identical
NEN 11217 : 1996 Identical

BS EN 60601-2-64:2015 Medical electrical equipment Particular requirements for the basic safety and essential performance of light ion beam medical electrical equipment
08/30170297 DC : DRAFT MAR 2008 BS EN 62083 - MEDICAL ELECTRICAL EQUIPMENT - REQUIREMENTS FOR THE SAFETY OF RADIOTHERAPY TREATMENT PLANNING SYSTEMS
BS EN 62274:2005 Medical electrical equipment. Safety of radiotherapy record and verify systems
BS EN 60601-2-11:2015 Medical electrical equipment Particular requirements for the basic safety and essential performance of gamma beam therapy equipment
BS EN 62083:2009 Medical electrical equipment. Requirements for the safety of radiotherapy treatment planning systems
NF EN 60601-2-29 : 2009 AMD 11 2012 MEDICAL ELECTRICAL EQUIPMENT - PART 2-29: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RADIOTHERAPY SIMULATORS
BS EN 60601-2-1:2015 Medical electrical equipment Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV
I.S. EN 60601-2-29:2008 MEDICAL ELECTRICAL EQUIPMENT - PART 2-29: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RADIOTHERAPY SIMULATORS (IEC 60601-2-29:2008 (EQV))
ISO 16142-1:2016 Medical devices — Recognized essential principles of safety and performance of medical devices — Part 1: General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards
I.S. EN 60601-2-64:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-64: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF LIGHT ION BEAM MEDICAL ELECTRICAL EQUIPMENT
CSA C22.2 No. 60601.2.11 : 2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-11: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF GAMMA BEAM THERAPY EQUIPMENT
16/30216785 DC : 0 BS EN 62667 - MEDICAL ELECTRICAL EQUIPMENT - MEDICAL LIGHT ION BEAM EQUIPMENT - PERFORMANCE CHARACTERISTICS
09/30182052 DC : DRAFT MAY 2009 BS EN 60601-2-8 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-8: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF THERAPEUTIC X-RAY EQUIPMENT OPERATING IN THE RANGE 10 KV TO 1 MV
I.S. EN 60976:2007 MEDICAL ELECTRICAL EQUIPMENT - MEDICAL ELECTRON ACCELERATORS - FUNCTIONAL PERFORMANCE CHARACTERISTICS
08/30168475 DC : DRAFT APR 2008 BS EN 60601-2-1 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-1: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF ELECTRON ACCELERATORS IN THE RANGE 1 MEV TO 50 MEV
CEI EN 62274 : 2005 MEDICAL ELECTRICAL EQUIPMENT - SAFETY OF RADIOTHERAPY RECORD AND VERIFY SYSTEMS
CSA C22.2 No. 60601-2-64 : 2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-64: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF LIGHT ION BEAM MEDICAL ELECTRICAL EQUIPMENT
I.S. EN 60601-2-11:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-11: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF GAMMA BEAM THERAPY EQUIPMENT
CSA C22.2 No. 601.2.29 : 0 MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR THE SAFETY OF RADIOTHERAPY SIMULATORS
I.S. EN 62083:2009 MEDICAL ELECTRICAL EQUIPMENT - REQUIREMENTS FOR THE SAFETY OF RADIOTHERAPY TREATMENT PLANNING SYSTEMS
IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
I.S. EN 60601-2-17:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-17: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATICALLY CONTROLLED BRACHYTHERAPY AFTERLOADING EQUIPMENT
NEMA PS3.3 : 2017A DIGITAL IMAGING AND COMMUNICATIONS IN MEDICINE (DICOM) - PART 3: INFORMATION OBJECT DEFINITIONS
VDE 0750-2-64 : 2018 MEDICAL ELECTRICAL EQUIPMENT - PART 2-64: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF LIGHT ION BEAM MEDICAL ELECTRICAL EQUIPMENT
NEMA PS 3.16 : 2017A DIGITAL IMAGING AND COMMUNICATIONS IN MEDICINE (DICOM) - PART 16: CONTENT MAPPING RESOURCE
DIN EN 60601-2-64 : 2018 MEDICAL ELECTRICAL EQUIPMENT - PART 2-64: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF LIGHT ION BEAM MEDICAL ELECTRICAL EQUIPMENT
NF EN 60601-2-64 : 2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-64: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF LIGHT ION BEAM MEDICAL ELECTRICAL EQUIPMENT
BS EN 60601-2-8 : 2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-8: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF THERAPEUTIC X-RAY EQUIPMENT OPERATING IN THE RANGE 10 KV TO 1 MV
CEI EN 60601-2-11 : 2016 MEDICAL ELECTRICAL EQUIPMENT - PART 2-11: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF GAMMA BEAM THERAPY EQUIPMENT
BS EN 60601-2-68:2015 Medical electrical equipment Particular requirements for the basic safety and essential performance of X-ray-based image-guided radiotherapy equipment for use with electron accelerators, light ion beam therapy equipment and radionuclide beam therapy equipment
14/30290166 DC : 0 BS ISO 16142-1 - MEDICAL DEVICES - RECOGNIZED ESSENTIAL PRINCIPLES OF SAFETY AND PERFORMANCE OF MEDICAL DEVICES - PART 1: GENERAL ESSENTIAL PRINCIPLES AND ADDITIONAL SPECIFIC ESSENTIAL PRINCIPLES FOR ALL NON-IVD MEDICAL DEVICES AND GUIDANCE ON THE SELECTION OF STANDARDS
BS ISO 16142-1:2016 Medical devices. Recognized essential principles of safety and performance of medical devices General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards
BS EN 60976 : 2008 MEDICAL ELECTRICAL EQUIPMENT - MEDICAL ELECTRON ACCELERATORS - FUNCTIONAL PERFORMANCE CHARACTERISTICS
02/564070 DC : DRAFT SEP 2002 BS EN 60601-2-17 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-17: PARTICULAR REQUIREMENTS FOR THE SAFETY OF AUTOMATICALLY-CONTROLLED BRACHYTHERAPY AFTERLOADING EQUIPMENT
12/30246621 DC : 0 BS EN 60601-2-68 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-68: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY BASED IMAGE GUIDED RADIOTHERAPY EQUIPMENT FOR USE WITH ELECTRON ACCELERATORS, LIGHT ION BEAM THERAPY EQUIPMENT AND RADIONUCLIDE BEAM THERAPY EQUIPMENT
07/30144241 DC : 0 BS IEC 60601-2-29 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-29: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RADIOTHERAPY SIMULATORS
CEI EN 60976 : 2009 MEDICAL ELECTRICAL EQUIPMENT - MEDICAL ELECTRON ACCELERATORS - FUNCTIONAL PERFORMANCE CHARACTERISTICS
CSA C22.2 No. 60601.2.17 : 2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-17: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATICALLY-CONTROLLED BRACHYTHERAPY AFTERLOADING EQUIPMENT
EN 60601-2-1:2015 Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV
CSA C22.2 No. 60601-2-68 : 2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-68: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY-BASED IMAGE-GUIDED RADIOTHERAPY EQUIPMENT FOR USE WITH ELECTRON ACCELERATORS, LIGHT ION BEAM THERAPY EQUIPMENT AND RADIONUCLIDE BEAM THERAPY EQUIPMENT
CEI EN 60601-2-1 : 2016 MEDICAL ELECTRICAL EQUIPMENT - PART 2-1: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF ELECTRON ACCELERATORS IN THE RANGE 1 MEV TO 50 MEV
IEC 60601-2-8:2010+AMD1:2015 CSV Medical electrical equipment - Part 2-8: Particular requirements forthe basic safety and essential performance of therapeutic X-ray equipment operating in the range 10 kV to 1 MV
BS EN 60601-2-17:2015 Medical electrical equipment Particular requirements for the basic safety and essential performance of automatically-controlled brachytherapy afterloading equipment
IEC 60601-2-17:2013 Medical electrical equipment - Part 2-17: Particular requirements for the basic safety and essential performance of automatically-controlled brachytherapy afterloading equipment
13/30216789 DC : 0 BS EN 60601-2-64 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-64: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF MEDICAL LIGHT ION BEAM MEDICAL EQUIPMENT
I.S. EN 62274:2005 MEDICAL ELECTRICAL EQUIPMENT - SAFETY OF RADIOTHERAPY RECORD AND VERIFY SYSTEMS
PD IEC TR 60788:2004 Medical electrical equipment. Glossary of defined terms
BS EN IEC 62667:2018 Medical electrical equipment. Medical light ion beam equipment. Performance characteristics
CEI EN 62083 : 2011 MEDICAL ELECTRICAL EQUIPMENT - REQUIREMENTS FOR THE SAFETY OF RADIOTHERAPY TREATMENT PLANNING SYSTEMS
I.S. EN IEC 62667:2018 MEDICAL ELECTRICAL EQUIPMENT - MEDICAL LIGHT ION BEAM EQUIPMENT - PERFORMANCE CHARACTERISTICS
EN 60601-2-68:2015 Medical electrical equipment - Part 2-68: Particular requirements for the basic safety and essential performance of X-ray-based image-guided radiotherapy equipment for use with electron accelerators, light ion beam therapy equipment and radionuclide beam therapy equipment
I.S. EN 60601-2-68:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-68: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY-BASED IMAGE-GUIDED RADIOTHERAPY EQUIPMENT FOR USE WITH ELECTRON ACCELERATORS, LIGHT ION BEAM THERAPY EQUIPMENT AND RADIONUCLIDE BEAM THERAPY EQUIPMENT
EN IEC 62667:2018 Medical electrical equipment - Medical light ion beam equipment - Performance characteristics
I.S. EN 60601-2-1:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-1: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF ELECTRON ACCELERATORS IN THE RANGE 1 MEV TO 50 MEV
IEC TR 61852:1998 Medical electrical equipment - Digital imaging and communications in medicine (DICOM) - Radiotherapy objects
I.S. EN 60601-2-8:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-8: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF THERAPEUTIC XRAY EQUIPMENT OPERATING IN THE RANGE 10 KV TO 1 MV
EN 60601-2-8:2015/A1:2016 MEDICAL ELECTRICAL EQUIPMENT - PART 2-8: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF THERAPEUTIC X-RAY EQUIPMENT OPERATING IN THE RANGE 10 KV TO 1 MV (IEC 60601-2-8:2010/A1:2015)
IEC 62274:2005 Medical electrical equipment - Safety of radiotherapy record and verify systems
IEC 60976:2007 Medical electrical equipment - Medical electron accelerators - Functional performance characteristics
IEC 60601-2-1:2009+AMD1:2014 CSV Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV
IEC 60601-2-29:2008 Medical electrical equipment - Part 2-29: Particular requirements for the basic safety and essential performance of radiotherapy simulators
IEC 60601-2-11:2013 Medical electrical equipment - Part 2-11: Particular requirements for the basic safety and essential performance of gamma beam therapy equipment
UNE-EN 62083:2010 Medical electrical equipment - Requirements for the safety of radiotherapy treatment planning systems
IEC 62083:2009 Medical electrical equipment - Requirements for the safety of radiotherapy treatment planning systems
UNE-EN 60601-2-1:2017 Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV
10/30206488 DC : 0 BS EN 60601-2-17 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-17: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATICALLY-CONTROLLED BRACHYTHERAPY AFTERLOADING EQUIPMENT
EN 60601-2-64:2015 Medical electrical equipment - Part 2-64: Particular requirements for the basic safety and essential performance of light ion beam medical electrical equipment
BS EN 60601-2-29 : 2008 MEDICAL ELECTRICAL EQUIPMENT - PART 2-29: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RADIOTHERAPY SIMULATORS
NF EN 60601-2-68 : 2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-68: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY-BASED IMAGE-GUIDED RADIOTHERAPY EQUIPMENT FOR USE WITH ELECTRON ACCELERATORS, LIGHT ION BEAM THERAPY EQUIPMENT AND RADIONUCLIDE BEAM THERAPY EQUIPMENT
EN 60601-2-11:2015 Medical electrical equipment - Part 2-11: Particular requirements for the basic safety and essential performance of gamma beam therapy equipment
EN 62274:2005 Medical electrical equipment - Safety of radiotherapy record and verify systems
EN 60976:2007 Medical electrical equipment - Medical electron accelerators - Functional performance characteristics
EN 62083:2009 MEDICAL ELECTRICAL EQUIPMENT - REQUIREMENTS FOR THE SAFETY OF RADIOTHERAPY TREATMENT PLANNING SYSTEMS
EN 60601-2-29:2008/A11:2011 MEDICAL ELECTRICAL EQUIPMENT - PART 2-29: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RADIOTHERAPY SIMULATORS
EN 60601-2-17:2015 Medical electrical equipment - Part 2-17: Particular requirements for the basic safety and essential performance of automatically-controlled brachytherapy afterloading equipment
CSA C22.2 No. 60601.2.1 : 2011 MEDICAL ELECTRICAL EQUIPMENT - PART 2-1: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF ELECTRON ACCELERATORS IN THE RANGE 1 MEV TO 50 MEV
CSA C22.2 No. 60601.2.29 : 2010 MEDICAL ELECTRICAL EQUIPMENT - PART 2-29: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RADIOTHERAPY SIMULATORS
NBR IEC 60601-2-1 : 2011 ERRATA 1 2013 MEDICAL ELECTRICAL EQUIPMENT - PART 2-1: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF ELECTRON ACCELERATORS IN THE RANGE 1 MEV TO 50 MEV
CSA C22.2 No. 60601.2.1 : 2011 : INC : AMD 1 : 2015 : R2016 MEDICAL ELECTRICAL EQUIPMENT - PART 2-1: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF ELECTRON ACCELERATORS IN THE RANGE 1 MEV TO 50 MEV

IEC 61168:1993 Radiotherapy simulators - Functional performance characteristics
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
IEC 60976:2007 Medical electrical equipment - Medical electron accelerators - Functional performance characteristics
IEC 62083:2009 Medical electrical equipment - Requirements for the safety of radiotherapy treatment planning systems
IEC TR 60977:2008 Medical electrical equipment - Medical electron accelerators - Guidelines for functional performance characteristics
IEC 60601-1-3:2008+AMD1:2013 CSV Medical electrical equipment - Part 1-3: General requirements forbasic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment
IEC 60601-2-1:2009+AMD1:2014 CSV Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV
IEC 60601-2-29:2008 Medical electrical equipment - Part 2-29: Particular requirements for the basic safety and essential performance of radiotherapy simulators
IEC 60601-2-11:2013 Medical electrical equipment - Part 2-11: Particular requirements for the basic safety and essential performance of gamma beam therapy equipment

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.