I.S. EN 60601-2-47:2015

Current

Current

The latest, up-to-date edition.

MEDICAL ELECTRICAL EQUIPMENT - PART 2-47: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AMBULATORY ELECTROCARDIOGRAPHIC SYSTEMS

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2015

Preview

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

US$102.53
Excluding Tax where applicable

FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing of
      ME EQUIPMENT
201.6 Classification of ME EQUIPMENT
      and ME SYSTEMS
201.7 ME EQUIPMENT identification, marking
      and documents
201.8 Protection against electrical HAZARDS from
      ME EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS
      of ME EQUIPMENT and ME SYSTEMS
201.10 Protection against unwanted and excessive
       radiation HAZARDS
201.11 Protection against excessive temperatures and
       other HAZARDS
201.12 Accuracy of controls and instruments and
       protection against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault
       conditions
201.14 PROGRAMMABLE ELECTRICAL MEDICAL
       SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME
       EQUIPMENT and ME SYSTEMS
202 Electromagnetic compatibility - Requirements
       and tests
Annexes
Annex AA (informative) - Particular guidance and rationale
Bibliography
Index of defined terms used in this particular standard
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications
Annex ZZ (informative) - Coverage of Essential
         Requirements of EU Directives

Pertains to the BASIC SAFETY and ESSENTIAL PERFORMANCE of AMBULATORY ELECTROCARDIOGRAPHIC SYSTEMS, hereafter referred to as ME SYSTEMS.

DevelopmentNote
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
DocumentType
Standard
Pages
148
PublisherName
National Standards Authority of Ireland
Status
Current

Standards Relationship
DIN EN 60601-2-47 : 2016 Identical
EN 60601-2-47:2015 Identical
BS EN 60601-2-47:2015 Identical
UNE-EN 60601-2-47:2002 Identical

IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
EN 60601-1-2:2015 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60601-2-27:2011 Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment
IEC 60601-2-25:2011 Medical electrical equipment - Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.