I.S. EN 50125-2:2003
Current
The latest, up-to-date edition.
RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS
Hardcopy , PDF
English
01-01-2003
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
1 Scope
2 Normative references
3 Definitions
4 Environmental conditions
4.1 General
4.2 Altitude
4.3 Air temperature and humidity
4.4 Air movement
4.5 Rain
4.6 Hail
4.7 Snow and ice
4.8 Solar radiation
4.9 Vibration and shocks
4.10 Pollution
4.11 Lightning
4.12 Electromagnetic compatibility
4.13 Fire protection
4.14 Environmental conditions in tunnels
Annex A (informative) Conditions relating to tunnels
Annex ZZ (informative) Coverage of Essential Requirements
of EC Directives
Bibliography
Deals with the environmental influences on fixed electrical installations for traction power supply and equipment essential to operate; - a railway; - in open air; - in covered areas; - in tunnels; - within enclosures placed in above areas.
DocumentType |
Standard
|
Pages |
14
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
BS EN 50125-2:2002 | Identical |
SN EN 50125-2 : 2002 | Identical |
NEN EN 50125-2 : 2003 C1 2010 | Identical |
UNE-EN 50125-2:2004 | Identical |
EN 50125-2:2002/corrigendum:2010 | Identical |
DIN EN 50125-2 : 2003 COR 1 2010 | Identical |
NF EN 50125-2 : 2003 | Identical |
EN 50125-3 : 2003 COR 2010 | RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 3: EQUIPMENT FOR SIGNALLING AND TELECOMMUNICATIONS |
EN 50124-2:2017 | Railway applications - Insulation coordination - Part 2: Overvoltages and related protection |
HD 478.2.3 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - AIR PRESSURE |
HD 478.2.2 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - PRECIPITATION AND WIND |
EN 50123-1:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 1: General |
HD 478.2.1 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - TEMPERATURE AND HUMIDITY |
IEC 60721-2-1:2013 | Classification of environmental conditions - Part 2-1: Environmental conditions appearing in nature - Temperature and humidity |
EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
IEC 60721-2-2:2012 | Classification of environmental conditions - Part 2-2: Environmental conditions appearing in nature - Precipitation and wind |
EN 50125-1:2014 | Railway applications - Environmental conditions for equipment - Part 1: Rolling stock and on-board equipment |
EN 50119 : 2009 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60721-3-2:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation |
ENV 1991-2-4 : 1995 | EUROCODE 1: BASIS OF DESIGN AND ACTIONS ON STRUCTURES - ACTIONS ON STRUCTURES - WIND ACTIONS (TOGETHER WITH UNITED KINGDOM NATIONAL APPLICATION DOCUMENT) |
EN 50121-5:2017 | Railway applications - Electromagnetic compatibility - Part 5: Emission and immunity of fixed power supply installations and apparatus |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
EN 50123-4:2003/A1:2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES |
EN 60721-3-2:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60721-3-4:1995/A1:1997 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 4: STATIONARY USE AT NON-WEATHER-PROTECTED LOCATIONS |
IEC 60721-2-3:2013 | Classification of environmental conditions - Part 2-3: Environmental conditions appearing in nature - Air pressure |
EN 60721-3-3 : 95 AMD 2 97 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.