CEI EN 55011 : 2017
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
INDUSTRIAL, SCIENTIFIC AND MEDICAL EQUIPMENT - RADIO-FREQUENCY DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT
Hardcopy , PDF
11-01-2018
English - Italian
01-01-2017
European foreword
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Frequencies designated for ISM use
5 Classification of equipment
6 Limits of electromagnetic disturbances
7 Measurement requirements
8 Special provisions for test site measurements (9 kHz to
1 GHz)
9 Radiation measurements: 1 GHz to 18 GHz
10 Measurement in situ
11 Safety precautions for emission measurements on ISM RF
equipment
12 Measurement uncertainty
Annex A (informative) - Examples of equipment classification
Annex B (informative) - Precautions to be taken in the use of a
spectrum analyzer
Annex C (normative) - Measurement of electromagnetic radiation
disturbance in the presence of signals from radio
transmitters
Annex D (informative) - Propagation of interference from
industrial radio-frequency equipment at frequencies
between 30 MHz and 300 MHz
Annex E (informative) - Recommendations of CISPR for
protection of certain radio services in particular
areas
Annex F (informative) - Frequency bands allocated for
safety-related radio services
Annex G (informative) - Frequency bands allocated for
sensitive radio services
Annex H (informative) - Statistical assessment of series
produced equipment against the requirements
of CISPR standards
Annex I (normative) - Artificial Network (AN) for the
assessment of disturbance voltages at d.c. power
ports of semiconductor power converters
Annex J (informative) - Measurements on Grid Connected
Power Converters (GCPC) - Setups for an effective
test site configuration
Annex K (informative) - Test site configuration and
instrumentation - Guidance on prevention of
saturation effects in mitigation filters of
transformer-less power converters during
type tests according to this standard
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Annex ZB (normative) - Frequencies designated on a national
basis in CENELEC countries for use as fundamental
ISM frequencies
Annex ZZ (informative) - Coverage of Essential Requirements
of EU Directives
Bibliography
Pertains to industrial, scientific and medical electrical equipment operating in the frequency range 0 Hz to 400 GHz and to domestic and similar appliances designed to generate and/or use locally radio-frequency energy.
Committee |
CT 210
|
DevelopmentNote |
Classificazione CEI 110-6 (08/2001) 5ED 2013 Edition is valid until 15-02-2019. (02/2017)
|
DocumentType |
Standard
|
Pages |
102
|
PublisherName |
Comitato Elettrotecnico Italiano
|
Status |
Withdrawn
|
SupersededBy |
CEI 64-8/5 : 2012 | LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 5: ERECTION AND SELECTION OF ELECTRICAL EQUIPMENT |
UNI 10566 : 2013 | ELECTROFUSION WELDING MACHINES AND AUXILIARY EQUIPMENT FOR POLYETHYLENE PIPES AND/OR FITTING JOINTS BY ELECTROWELDABLE CONNECTIONS FOR GAS, WATER AND OTHERS PRESSURE FLUIDS PIPELINES CONSTRUCTION, TEST AND MAINTENANCE REQUIREMENTS, DOCUMENTATION |
CISPR 14-1:2016 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
EN 62135-2:2015 | Resistance welding equipment - Part 2: Electromagnetic compatibility (EMC) requirements |
CISPR 16-4-2:2011+AMD1:2014 CSV | Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty |
EN 55016-2-3:2017 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
EN 55016-1-4:2010/A2:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017) |
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
IEC 61689:2013 | Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
IEC 60364-5-51:2005 | Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules |
CISPR 16-2-1:2014 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements |
IEC 61922:2002 | High-frequency induction heating installations - Test methods for the determination of power output of the generator |
CISPR 15:2013+AMD1:2015 CSV | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
IEC 60974-10:2014+AMD1:2015 CSV | Arc welding equipment - Part 10: Electromagnetic compatibility (EMC)requirements |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
EN 60601-1-2:2015 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
IEC 60601-2-2:2017 | Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories |
IEC 61308:2005 | High-frequency dielectric heating installations - Test methods for the determination of power output |
EN 61307:2011 | Industrial microwave heating installations - Test methods for the determination of power output |
IEC 62135-2:2015 | Resistance welding equipment - Part 2: Electromagnetic compatibility (EMC) requirements |
CISPR 16-2-3:2016 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
EN 60974-10:2014/A1:2015 | ARC WELDING EQUIPMENT - PART 10: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS (IEC 60974-10:2014/A1:2015) |
CEI 62-11 : 1ED 1983 | APPARECCHI ELETTROMEDICALI. NORME PARTICOLARI DI SICUREZZA PER GLI APPARECCHI DI ELETTROCHIRURGIA AD ALTA FREQUENZA |
IEC 61307:2011 | Industrial microwave heating installations - Test methods for the determination of power output |
EN 55016-2-1:2014/A1:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 2-1: METHODS OF MEASUREMENT OF DISTURBANCES AND IMMUNITY - CONDUCTED DISTURBANCE MEASUREMENTS (CISPR 16-2-1:2014/A1:2017) |
IEC 60705:2010+AMD1:2014 CSV | Household microwave ovens - Methods for measuring performance |
EN 55016-1-1:2010/A2:2014 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.