Ambient air. Determination of total non-methane organic compounds. Cryogenic preconcentration and direct flame ionization detection method
Hardcopy , PDF
English
05-15-2000
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Description of the method
4.1 Sampling
4.2 Analysis
5 Interferences
6 Apparatus
6.1 Sample collection system (Figure 1)
6.2 Sample-canister cleaning system (Figure 2)
6.3 Analytical system (Figure 3)
7 Reagents and materials
8 Canister cleanup and preparation
9 Sampling
9.1 General
9.2 Sample collection
10 Sample analysis
10.1 Assembly
10.2 Analytical system leak check
10.3 Sample volume determination
10.4 Analytical system dynamic calibration
10.5 Analysis procedure (see Figure 3)
11 Performance criteria and Quality Assurance
11.1 General
11.2 Standard operating procedure (SOP)
11.3 Method sensitivity,accuracy and precision
12 Method modification
12.1 Sample metering system
12.2 Canister cleaning
12.3 FID system
12.4 Range
12.5 Alternative cryogenic trapping and heating
systems
12.6 Sub-atmospheric pressure canister sampling
12.7 Alternative sampling system
13 Precision and accuracy
13.1 Precision
13.2 Accuracy
Annex A (informative) Example of pressurized canister
Sampling Data Sheet
Bibliography
Describes a method for sampling and determination of concentrations of total non-methane volatile organic compounds (NMVOC) in the ambient atmosphere.
Committee |
EH/2/3
|
DevelopmentNote |
Supersedes 96/562875 DC. (07/2005)
|
DocumentType |
Standard
|
Pages |
30
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This International Standard describes a procedure for sampling and determining concentrations of total non-methane volatile organic (NMVOC)in the ambient atmosphere.
This International Standard describes the collection of cumulative samples in passivated stainless steel canisters and subsequent laboratory analysis. It describes a procedure for sampling in canisters at final pressures above atmospheric pressure (referred to as pressurized sampling). It employs a cryogenic trapping procedure for concentration of the NMVOC prior to analysis.
This International Standard describes the determination of the NMVOC by simple flame ionization detection (FID), without the gas chromatographic columns and complex procedures necessary for species separation.
This International Standard is applicable to carbon concentrations in the range from 20 ppbC to 10 000 ppbC. See 12.4 for procedures for lowering the range.
Several variations to the method described in this International Standard are also possible; see clause 12.
Standards | Relationship |
ISO 14965:2000 | Identical |
ISO/TR 4227:1989 | Planning of ambient air quality monitoring |
ISO 6145-4:2004 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 4: Continuous syringe injection method |
ISO 6145-3:1986 | Gas analysis Preparation of calibration gas mixtures Dynamic volumetric methods Part 3: Periodic injections into a flowing gas stream |
ISO 6145-1:2003 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 1: Methods of calibration |
ISO 6141:2015 | Gas analysis Contents of certificates for calibration gas mixtures |
ISO 6145-6:2017 | Gas analysis — Preparation of calibration gas mixtures using dynamic methods — Part 6: Critical flow orifices |